Alarm/Fault codes
10
3B6
Troubleshooting Manual
ALARM 60
A2B condition
Approaching A2B condition
Lower hook block.
Check A2B switch cable
ALARM 61
Overload SWL
110%
Exceeded 110% SWL
Reduce SWL
ALARM 62
Overload SWL
115%
Exceeded 115% SWL
Reduce SWL
ALARM 63
Overload SWL
120%
Exceeded 120% SWL
Reduce SWL
ALARM 64
Bypass enabled
Faulty wiring
System bypassed
Check wiring from harness to
bypass
ALARM 70
Rotation pot
ADC value
Faulty wiring
Internal fault rotation pot
Check wiring from harness to
rotation pot
Call Service
ALARM 71
Rotation prox
switch
Faulty mechanical hardware
Internal fault SLIM display
Check wiring from harness to
rotation pot
Check pot hardware
ALARM 72
Rotation sensor
malfunction
Faulty wiring
Defective rotation sensor
Check wiring from harness to
rotation sensor
Call Service