manualshive.com logo in svg
background image

 

Pendulum 
single 
measu-
rement 

When button 

‘START/ 

STOP’

 is pressed, a 

single measurement is 
started 

PERIODES 

Continu-
ous 

When button 

‘START 

/STOP’

 is pressed, the 

period time is meas-
ured continuously 

 

Single 
measu-
rement 

When button 

‘START 

/STOP’

 is pressed, a 

single measurement is 
started 

 

Pendulum 
continu-
ous 

When button 

‘START 

/STOP’

 is pressed, a 

pendulum’s period time 
is cont. measured. 

 

Pendulum 
single 
measu-
rement 

When button 

‘START 

/STOP’

 is pressed, a 

single measurement is 
started 

IMPULSE 
COUNT 

Continu-
ous 

When button 

‘START/STOP’

 is 

pressed, the im-
pulse counting is 
started, and runs 
until 

‘START/STOP’

 

is pressed again 

 

1 s          
6 s        
10 s       
60 s 

When button 

‘START 

/STOP’

 is pressed, 

counting for 1 / 6 / 10 
or 60 s is started 

 

Count 10 s 
Hold 5 s  

When button 

‘START/STOP’

 is 

pressed, counting for 
10 s is started fol-
lowed by 5 s pause 

 

10 s Con-
tinuous 

When button 

‘START/STOP’

 is 

pressed, sequential 
counting for 10 sec 
is started 

At frequency, period and impulse measure-
ments, only input A is used. 

START A - 
STOP B 
[START] 

 

When button 

‘START/STOP’

 is 

pressed, the time from 
A to B is measured 

PASS 
TIME 
[START] 

 

When button 

‘START 

/STOP’

 is pressed, 

pass times on A and 
B are measured (up 
to 9 measurements 
per channel) 
 

RUN & 
PASS 
TIME 
[START] 

 

When button 

‘START 

/STOP’

 is pressed, 

the run time from A to 
B, and the pass time 
for A and B are 
measured. 

On each of the above three functions (and the 
pendulum selection in frequency and period), 
the following applies: 
When 

‘FUNCTION’

 and 

‘SELECT’

 are pressed 

simultaneously, the start-/stop-polarity triggering 
is shown on the display. 
Pressing 

‘SELECT’

 shifts through the four (two) 

different combinations possible. 
Press 

‘START/STOP’

 to store the selection in 

memory for each individual function. The setup 
is memorized, even when the power is off. 

 

Geiger-Müller amplifi er module 

Function

 

Select

 

Description

 

IMPULSE 
COUNT 
GM 

Continu-
ous 

When button 

‘START/STOP’

 is 

pressed, GM input 
counting is started, 
and runs until 

‘START/STOP’

 is 

pressed again 

 

1 s          6 
s        10 s   
60 s 

When button 

‘START/STOP’

 is 

pressed, GM input 
counting for 1 / 6 / 
10 or 60 s is 
started 

 

Count 10 s 
Hold 5 s  

When button 

‘START/STOP’

 is 

pressed, GM input 
counting for 10 s is 
started followed by 
5 s pause 

 

10 s Con-
tinuous 

When button 

‘START/STOP’

 is 

pressed, sequen-
tial GM input 
counting for 10 sec 
is started 

 

5.1 Frequency measurement 

 

Select frequency measuring with the push-
button 

‘FUNCTION’

 and hereafter the wan-

ted measuring function with the push-button 

‘SELECT’

 

Press the button 

‘START/STOP’

 to start the 

frequency measurement. 

If the measuring function ‘Single measuring’ or 
‘Pendulum Single‘ (pendulum), has been se-
lected, a new frequency measurement is made 

Содержание PHYSICS 1003122

Страница 1: ...d for any reason that non hazardous operation will not be possible e g visi ble damage the counter should be switched off immediately and secured against any unintended use Before using the counter for the first time confirm that the specifications printed on the rear side of the housing are compatible with the local mains voltage Replace a faulty fuse only with one matching the specifications sta...

Страница 2: ...se with display of results START STOP Push button to start and stop of measure ment Hz LED for indication of measurement in Hz kHz LED for indication of measurement in kHz s LED for indication of measurement in sec onds ms LED for indication of measurement in milli seconds 4 digit LED display for results 2x16 character LCD display for function selection setup etc A LED indicator for input A B LED ...

Страница 3: ...0 60 Hz 1003123 230 V 10 50 60 Hz Power consumption 20 VA approx Dimensions 95x245x185 mmapprox Weight 5 kg approx 5 Operation The instrument is powered by activating the switch marked POWER Immediately on power on the instrument dis plays the version number i e r 1 1 00 00 00 for approx 2 secs The counter is now ready for use The selected function and method of measure ment are shown in the LCD d...

Страница 4: ...ART When button START STOP is pressed the run time from A to B and the pass time for A and B are measured On each of the above three functions and the pendulum selection in frequency and period the following applies When FUNCTION and SELECT are pressed simultaneously the start stop polarity triggering is shown on the display Pressing SELECT shifts through the four two different combinations possib...

Страница 5: ...then reset and prepared for a new measurement If 10s Continuous has been selected the counter is started when START STOP is pres sed The counting sequence is continuous with 10 seconds counting followed by a 5 seconds displaylock for reading the result The counter is reset and restarted every 10 seconds even if the display is locked the counter is still count ing The function is stopped when FUNCT...

Страница 6: ...light emitting diode at Input A and Input B are turned off A must be passed before B If A is passed several times before B the time in memory is the first passage of A The light emitting diodes Input A and Input B are turned off and the run time is displayed When the push button SELECT is pressed the pass time A is displayed and another push on SELECT displayes the pass time B If SELECT is pressed...

Страница 7: ...lect the language Programme Information Displays the version of the programme etc If a counter is connected the version of the instrument is also displayed Exit Exit programme In the menu Function all of the above de scribed measurement methods are available The following keys can be used when IMPULSE COUNT or IMPULSE COUNT GM were chosen Measurement method IMPULSE COUNT IMPULSE COUNT GM Impulse c...

Страница 8: ......