4. Technical data 

Input A and B 

Input impedance: 

500 k

 

Sensitivity: 200 

mV 

Trigger 

polarity: 

positive going or 
negative going, indi-
vidually selectable in 
each function if rele-
vant 

Frequency 

Range: 

0.01 Hz – 99,9 kHz 

Resolution: 

0.01 Hz - 10 Hz 

Method: continuous 

single 

measurement 

Period

 

Range: 

0.01 Hz – 99.9 kHz 

Resolution: 

0.01 ms - 10 ms  

Method: continuous 

single 

measurement 

Impulse count 

Range: 

0 - 9999 impulses per s 

Resolution: 1 

impulse 

Method: continuous; 

counting for 1 s; 6 s; 10 
s and 60 s; 
counting for 10 s fol-
lowed by 5 s pause; 
counting for 10 s con-
tinuous 

Start A - Stop B 

Range: 

0.01 ms - 100 s 

Resolution: 0.01 

ms 

Pass time 

Range: 

0.01 m - 100 s 

Resolution: 0.01 

ms 

Method: 

simultaneous on both 
channels 

Memory: 

up to 9 times per 
channel 

Pass / Run time 

Range: 

0.01 ms - 100 s 

Resolution: 0.01 

ms 

Method: 

first pass time on A, 
then pass time on B 

Memory: 

one set of measure-
ments (run time A to 
B, pass time A and 
pass time B) 

Geiger-Müller amplifi er module 

Anode resistor: 

10 M

 (Ri) 

GM voltage range: 

325 – 650 V DC con-
tinuously adjustable 

Hint: Voltage can be measured with a 10 M

 

multimeter, and multiplied by 2. 

General data 

Mains connection: 

 

1003122: 

115 V (±10 %), 50/60 Hz 

1003123: 

230 V (±10 %), 50/60 Hz 

Power consumption: 

20 VA approx. 

Dimensions: 95x245x185 

mm

 

approx. 

Weight: 

5 kg approx. 

 
 

5. Operation 

The instrument is powered by activating the 
switch marked 

‘POWER’

Immediately on power-on the instrument dis-
plays the version number (i.e. ‘r 1 1.00 .00 .00’ 
for approx. 2 secs.). 
The counter is now ready for use. 
The selected function and method of measure-
ment are shown in the LCD-display. 
To change language turn off the power, hold the 

‘SELECT’

 and simultaneous switch on the power. 

Use the 

‘SELECT’

 button to change the lan-

guage, press 

‘FUNCTION’

 to store the selection 

in memory. 
Select a function with the push-button 

‘FUNC-

TION’

 and then the measuring method with the 

pushbutton 

‘SELECT’

.  

If the selected function has the option to select 
the trigger polarity, then a simultaneous push on 

‘FUNCTION’

 and 

‘SELECT’

 displays the trigger 

polarity in the LCD-display for each input. 
Pushing the 

‘SELECT’

 changes the trigger po-

larity. Push the 

‘START/STOP’

 to store the se-

lection in memory. 

 

List of the functions and measurement me-
thods: 

Function

 

Select

 

Description

 

FRE-
QUENCY 

Continu-
ous 

When button 

‘START/STOP’

 is 

pressed, frequency 
is continuously 
measured 

 

Single 
measu-
rement 

When button 

‘START/STOP’

 is 

pressed, a single 
measurement is 
started 

 

Pendulum 
continu-
ous 

When button 

‘START/STOP’

 is 

pressed, a pendu-
lum’s freq. is con-
tinuously measured 

Содержание PHYSICS 1003122

Страница 1: ...d for any reason that non hazardous operation will not be possible e g visi ble damage the counter should be switched off immediately and secured against any unintended use Before using the counter for the first time confirm that the specifications printed on the rear side of the housing are compatible with the local mains voltage Replace a faulty fuse only with one matching the specifications sta...

Страница 2: ...se with display of results START STOP Push button to start and stop of measure ment Hz LED for indication of measurement in Hz kHz LED for indication of measurement in kHz s LED for indication of measurement in sec onds ms LED for indication of measurement in milli seconds 4 digit LED display for results 2x16 character LCD display for function selection setup etc A LED indicator for input A B LED ...

Страница 3: ...0 60 Hz 1003123 230 V 10 50 60 Hz Power consumption 20 VA approx Dimensions 95x245x185 mmapprox Weight 5 kg approx 5 Operation The instrument is powered by activating the switch marked POWER Immediately on power on the instrument dis plays the version number i e r 1 1 00 00 00 for approx 2 secs The counter is now ready for use The selected function and method of measure ment are shown in the LCD d...

Страница 4: ...ART When button START STOP is pressed the run time from A to B and the pass time for A and B are measured On each of the above three functions and the pendulum selection in frequency and period the following applies When FUNCTION and SELECT are pressed simultaneously the start stop polarity triggering is shown on the display Pressing SELECT shifts through the four two different combinations possib...

Страница 5: ...then reset and prepared for a new measurement If 10s Continuous has been selected the counter is started when START STOP is pres sed The counting sequence is continuous with 10 seconds counting followed by a 5 seconds displaylock for reading the result The counter is reset and restarted every 10 seconds even if the display is locked the counter is still count ing The function is stopped when FUNCT...

Страница 6: ...light emitting diode at Input A and Input B are turned off A must be passed before B If A is passed several times before B the time in memory is the first passage of A The light emitting diodes Input A and Input B are turned off and the run time is displayed When the push button SELECT is pressed the pass time A is displayed and another push on SELECT displayes the pass time B If SELECT is pressed...

Страница 7: ...lect the language Programme Information Displays the version of the programme etc If a counter is connected the version of the instrument is also displayed Exit Exit programme In the menu Function all of the above de scribed measurement methods are available The following keys can be used when IMPULSE COUNT or IMPULSE COUNT GM were chosen Measurement method IMPULSE COUNT IMPULSE COUNT GM Impulse c...

Страница 8: ......

Отзывы: