Invictus Installation Manual V2.1.25.3
Page 13
© 360 Vision Technology Ltd.
Ethernet connections between Invictus PSU and Invictus that is fitted with HMA.
The Ethernet connection uses standard CAT5, CAT5e or CAT6 cables fitted with RJ45 connectors.
RJ45
CAT5, CAT5e, CAT6 Cable
Signal
Pin 1
White with Orange Band
Tx+
Pin 2
Orange
Tx-
Pin 3
White with Green Band
Rx+
Pin 4
Blue
Pin 5
White with Blue Band
Pin 6
Green
Rx-
Pin 7
White with Brown Band
Pin 8
Brown
Gain access to connectors in the HMA
•
Ensure that the fixed part of the HMA is securely bolted to the top of the pole.
•
The hinged part of the HMA (Hinged Mount Adapter) is fastened to the fixed part using three M8x25
long hex head bolts. Use a spanner (13mm) to remove the three bolts. Each bolt is fitted with a
split spring lock washer, a plain metal washer (which prevents the split washer from damaging the
fibre washer) and a fibre washer (which prevents the paint on the hinged part from being damaged
unnecessarily.
• Open the hinge taking care that the gasket is not damaged and support the weight of the Invictus.
Gently open the HMA until the lanyard is able to take the weight. If the lanyard appears to support
the weight of the Invictus, there is no need to continue to support the Invictus. The connection circuit
board (PCB-000-0262-xx) can now be seen.
Analogue Camera output
Use BNC for analogue video output.
Power Connections
Connect 24Vac/30vdc to CON5.
RS485 Connection
Use CON7 to connect the RS485 twisted pair data.
Washer Connection (If feature is present)
Use CON6 to connect washer signal to Invictus washer
PSU (PCB-000-0240-xx) CON 9
Ethernet Connections
Connect Ethernet cable to HD HMA Invictus connection
board using a RJ45 connector (CON4).
Please make sure there is adequate spare cable (20cm) for when the camera is resting on the lanyard, failure
to do this could damage the connector circuit board.