7.3
Connecting the DVI-100
Connect the Ethernet port of the DVI-100 to the PC. The IP-settings of the PC must
allow it to access the DVI-100 (default IP: 192.168.0.199).
7.4
Update using the Windows command line client
Start the Windows command line by using "Start" / "Execute" and then type "cmd"
Change to the directory where you've put the firmware files
Transfer the .pfw file to the device, using the command
tftp –i 192.168.0.199 PUT filename.pfw
The IP here is the default IP of the DVI-100, if this IP is changed you have to give the
correct IP address instead. Also "filename.pfw" must be replaced by the real firmware
file name.
The transfer will take some seconds; unfortunately the software won't give you any
feedback of the progress. After some seconds you should see the success output like
this:
Now you'll perform the same action again, but now for the ".pch" file.