DVI-100: Client mode
5.1
Activation of the client mode
To define the DVI-100 device to work as client, the configuration site at “DVI >>
General configuration” contains the relevant settings.
The option “DVI-100 mode” is the main selection and has to be set to “Client”.
Own DV IP Port
Sending and listening port at the Ethernet interface of the DVI-100 (Default is port
3141).
Default Call SSI
Messages received on the Ethernet interface which have no explicit target information
are directed to this target in the TETRA network. This is, by default, the current
selected group. The destination can be also any individual device. In a back-to-back
configuration this is also the target where all calls and messages will go to.
Alive message interval
The client cyclically sends an alive-message to the server via the Ethernet interface. The
time span of this interval can be defined in the range of 5 to 99 seconds. If the server
does not respond, the client tries periodically to reconnect to the DVI server.
Monitoring
The monitoring functionality needs to have an IP address and port information. While
operating the DVI spreads all incoming voice and message data also to the configured
monitoring target in the Ethernet network.