46
2N TELEKOMUNIKACE a.s., www.2n.cz
®
Gateway Configuration
System parameters
General
Saving call data (CDR)
– select the call types on which records are to be saved
into the CDR file.
Gateway ID
– identifies
numerically in the CDR in case
2N VoiceBlue Next
®
multiple devices generate the CDR in the network.
Summer/winter time
Automatically switch to summer/winter time
– enable an automatic change
of the gateway system time at the time of transition to/from the daylight saving
time.
Date of switch to winter time [dd.mm]
– transition day and month.
Date of switch to summer time [dd.mm]
– transition day and month.
System Restart
Enable system restart
– enable/disable the feature.
Time of system restart [hh:mm]
– set the time for system restart.
Mobility Extension (DTMF settings)
Start dialling (quick call forwarding)
– DTMF code for quick forwarding start.
End dialling (quick call forwarding)
– DTMF code for quick forwarding end.
Hold call
– DTMF code for active call holding.
Hang up call
– DTMF code for call termination.
Follow me activation
– activation of the
function. The GSM
Follow me
gateway starts routing call to the defined GSM/UMTS subscriber number. The
default value is *55.
Follow me deactivation
– deactivation of the
function. The default
Follow me
value is #55.
SMS at no answer activation
– activation of the
function
SMS at no answer
for a registered user. The default value is *33.
SMS at no answer deactivation
– deactivation of the
SMS at no answer
function for a registered user. The default value is #33.
Note
If there are active calls, restart will be executed 10 seconds after the end
of the last call.