Review of Programming Functions
3.2
53
Function
Number and Name
Value Range
Initializa-
tion Value
Notes, Explanations
811
821
Switch 1,2,3 password
addition
up to 16 digits
00
Adds another password to the list. The password
may
not be identical
with any other password;
otherwise it is rejected. Password 00 may not be
entered from a keyboard. Each switch can have up
to 10 passwords.
11
812
822
832
Switch 1,2,3 password
removal
Valid password
–
Removes a password from the list.
WARNING!
Remember to cancel password
00
with this function if you do not intend to use it!
Forgotten passwords can be removed by
initialization only.
813
823
833
Switch 1,2,3 activation
time
0–9 (seconds)
5 s
0 = the switch is out of operation
901
– dialing type
0 or 1
0 = tone
1=pulse 40/60
902
– dialing start time
(after pick-up)
5 to 99
corresponds to
0.5 to 9.9 s
33 =
3.3 seconds
Time between pick-up and dialing start.
Do not set time less than 2.7 s as required by
the TBR-21 standard.
903
– DTMF level
0–12
6
1 step = 1 dB
904
– automatic dialing type
0–4
1
0 = disabled for all buttons
1 = loud dialing with confirmation
2 = silent dialing with confirmation
3, 4 = loud dialing without confirmation
1
)
911
– number of rings until
incoming call answering
1–99
2
Defines the moment of pick-up during ringing.
ATTENTION! Select 1 if connected to Lift Call
Connect, Order. No. 91330808E!
912
– maximum call duration
1 to 99
corresponds to
10 to 990 s
12 =
2 minutes
06 = 1 minute, 30 = 5 minutes, 99 = 16.5 minutes
The call can be prolonged by pressing
.
913
– seizure timeout
(for automatic dialing)
1–99
corresponds to
10 to 990 s
6 = 60
seconds
change!
The maximum time, during which the dispatcher
has to answer and send confirmation, otherwise
the
ST
hangs up and dials the following number.
Starts at the dialing end.
914
– delayed calling
0–9
(count of
cycles)
0 = no
delay
change!
applies to button 01 only
915
– hang-up timeout
between calls
5–99
corresponds to
0.5 to 9.9 s
55 = 5.5 s
Do not set time less than 5 s as required by the
TBR-21 standard.
916
– CANCEL input inversion
0 or 1
0
0 = contact closed (or voltage present) at
open
door,
1 = contact closed (or voltage present) at
closed
door.
Содержание SingleTalk
Страница 1: ...2N SingleTalk Lift Communicator User Manual Version 6 3 0 www 2n cz ...
Страница 8: ...Product Description 1 1 7 Optional indication elements backlit pictograms incl incandescent lamps ...
Страница 15: ......
Страница 45: ......
Страница 66: ...65 5 5 Technical parameters This section describes the technical parameters of the product ...
Страница 69: ......