Review of Programming Functions
3.2
54
Function
Number and Name
Value Range
Initializa-
tion Value
Notes, Explanations
931
– microphone trigger level
0–3
2
0 = maximum microphone
sensitivity
Th
es
e
fu
nc
tio
ns
r
ep
la
ce
o
ld
m
od
el
t
ri
m
m
er
s.
N
or
m
al
ly
w
e
do
n
ot
r
ec
om
m
en
d
to
c
ha
ng
e
th
e
se
tt
in
gs
.
A
ny
u
np
ro
fe
ss
io
na
l s
et
tin
g
m
ay
r
es
ul
t
in
si
ng
in
g
or
d
et
er
io
ra
te
u
nd
er
st
an
da
bi
lit
y.
932
– automatic response
speed
0–3
2
3 = maximum response
speed
933
– receiving volume
0–15
7
15 = maximum receiving
volume
934
– transmitting volume
0–15
7
15 = maximum transmitting
volume
935
– message volume
0–15
7
15 = max. message volume
936
– beep volume
0–12
12
12 = maximum tone volume
937
– DTMF hearing volume
0–3
3
3 = max. DTMF hearing
volume
938
– loudspeaker volume
0–15
7
15 = max. loudspeaker
volume
941
– minimum continuous
tone time
10–99
20=2s
If the tone is longer, the
ST
hangs up.
Th
ese
p
aramet
ers
are u
sed
fo
r
cal
l
h
an
g
-u
p
a
n
d
d
u
ri
n
g
au
to
mat
ic
d
ial
in
g
.
942
– min. busy tone period
0–2.55 s
8 = 0.08 s
These parameters set the
busy tone detection.
943
– max. busy tone period
0–2.55 s
70 = 0.7 s
944
– max. tone-space
difference
0–2.55 s
10 = 0.1 s
945
– min. count of busy tone
periods
2–9
4
946
– dual tone detection
setting
0 – 10
4 = 440 Hz
A
ll continuous, busy and ringing tones are
detected also as dual tones, if some of the
tone components is between 400 and 500
Hz. If both components are in this range,
set detector for lower one. Set 0 for 400 Hz
to 10 for 500 Hz.
This setting is not affecting the single tone
detection, which works allways between
300 and 550 Hz.
951
– min. ringing tone time
0.01 to 2 s
50 = 0.5 s
2
)
The longest ringing period
space must be in the interval
between parameters 952 and
953.
If the selected
count of periods is
exceeded, the call
is terminated. If
the automatic
dialing is on,
another attempt
follows.
3
)
952
–min. long space time
0.5 to 10 s
10 = 1 s
953
–max. long space time
1 to 10 s
60 = 6 s
954
–count of ringing periods
01–99
10
Hangs up after this count.
961
– maximum timeout for
pressing the next digit
1–9
5 [s]
During password entering, etc.
Содержание SingleTalk
Страница 1: ...2N SingleTalk Lift Communicator User Manual Version 6 3 0 www 2n cz ...
Страница 8: ...Product Description 1 1 7 Optional indication elements backlit pictograms incl incandescent lamps ...
Страница 15: ......
Страница 45: ......
Страница 66: ...65 5 5 Technical parameters This section describes the technical parameters of the product ...
Страница 69: ......