2N® SingleTalk Programming
3.1
49
Setting Acoustic Parameters
The
ST
automatic handsfree mode works as follows: if there is silence on both
sides, the sound channel is muted; if a threshold sound level is exceeded, the
loudspeaker or the microphone goes on depending on which party starts
talking, or is talking more loudly.
The optimum acoustic parameters are set by default. You are not
recommended to change them unless under exceptional circumstances. For a
change, use parameters 931 through 938.
Switch programming
Each of the 3 switches has its predefined password (00, 11 and 22) according
to the table. If you use a new password, do not forget to remove the old one
Up to 10 various passwords can be programmed for each switch. Thanks to it,
different persons can use different passwords and all you have to do to “block”
one person later , is to remove the person‘s password and keep the other
passwords valid.
All passwords are checked during programming, i.e. it is forbidden to enter
one password twice.
If you wish to use a faster switch control method (a password without
), be
careful while entering passwords of variable lengths: if a shorter password is
identical with the beginning of a longer one, you cannot control the switch with
the longer one. Moreover, if you use Automatic dialing with confirmation, your
passwords may not start with 1 to 5.
Содержание SingleTalk
Страница 1: ...2N SingleTalk Lift Communicator User Manual Version 6 3 0 www 2n cz ...
Страница 8: ...Product Description 1 1 7 Optional indication elements backlit pictograms incl incandescent lamps ...
Страница 15: ......
Страница 45: ......
Страница 66: ...65 5 5 Technical parameters This section describes the technical parameters of the product ...
Страница 69: ......