Indicator Connection
Basic connection
You can use any indicators (illuminated pictograms, e.g.) for basic connection. An
external power supply provides a sufficient indicator brightness level. As
2N LiftIP
®
contains only switches, connect a circuit for current limitation if necessary, even if
LEDs are used.
Requirements
the indicators should work at power outage).
12–24 V supply (backed up if
200 mA permanent current (even with bulbs).
Make sure that both the indicators are connected!
Warning
Keep the power supply polarity!
Use of LEDs mounted on 2N ® LiftIP electronics
Do not connect anything in this case. Light guides are used for this purpose to bring
light to the two panel holes (refer to Subs. 2.3
Electronics Panel Mounting).
2N LiftIP
®
Light guides are not included in the standard accessories.
Cable connected LEDs
Cable connected LEDs are used where illuminated pictograms are unavailable. They
are not included in the standard accessories, but supplied separately or as part of
customer deliveries. These LEDs are 5 mm in diameter and feature a very high