![2N LiftIP Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/2n/liftip/liftip_user-manual_439780024.webp)
2N TELEKOMUNIKACE a.s., www.2n.cz
24/92
Connect the button contacts to the ALARM terminal. ALARM is set to normally
open (N/O) by default (all jumpers on).
The button contact can be both N/O and N/C. Slide the right jumper out for N
/C.
Use jumpers for configuration. The jumper link is below the ALARM terminal.
ALARM Connection – Voltage Control
Tip
DC voltage
can be used. Make sure that the
ranging from 5 to 48 V
power supply is backed up against power outage.
Voltage is connected/disconnected for activation/deactivation. ALARM is set to
N/O by default.
Slide all the jumpers off the configuration jumper link to control ALARM by
voltage connection.
Keep only the right jumper on to control ALARM by voltage disconnection.
Use jumpers for configuration. The jumper link is below the ALARM terminal.
Warning
Keep polarity (see the cover print).