background image

Installation manual 2N® Analog Vario

70

 /  

77

1.
2.

3.

1.
2.




Example 1 – administration building, automatic dialling is off:

Button  01:  labelled  Mr.  Smith,  memory  1  =  Mr.  Smith's  line,  memory  3 

– 

secretary's  line, 

password for button 01 is 777.

Mr. Smith is leaving for holiday. He calls

 

2N

® 

Analog Vario

 and enters: 

777 

1

A visitor comes, presses Mr. Smith's button –

 

2N

® 

Analog Vario

 calls the secretary.

Mr. Smith comes back. He calls

 

2N

® 

Analog Vario

 and enters: 

777

0

.

Example 2 – family house, Silent Automatic Multiple Number Dialling:

Button  01:  labelled  The  Johnsons,  memory  1  =  living  room,  2  =  workshop,  3  =  Mr.  Johnson's 
mobile telephone, 4 = Mrs. Johnson's mobile telephone. Arrival/Departure password for button 
01 is 333.

The family is leaving for holiday. They call 

 

2N

® 

Analog Vario

 and enter: 

333

A visitor presses the Johnson's' button – 

 

2N

® 

Analog Vario

 calls Mr. Johnson's mobile 

phone and, if unsuccessful, Mrs. Johnson's mobile phone.

3.5 Maintenance

Cleaning

If used 

frequently, 

2N

® 

Analog Vario

, especially the keypad, gets dirty. To clean it, use a piece of 

soft  cloth  moistened  with  clean  water.  We  recommend  you  to  obey  the  following  principles 
while cleaning:

Never use aggressive detergents (such as abrasives or strong disinfectants);
Clean the device in dry weather in order to make waste water evaporate quickly.

Label Replacement, Programming Status Changes

For necessary steps refer to the preceding subsections. Keep the following for later changes:

this manual;
the completed programming form (including a copy);
unused transparent foil strips for button labels.

Caution

Always use the product for the purpose it was designed and manufactured for, in 
compliance herewith.
The manufacturer reserves the right to modify the product in order to improve its 
qualities.

2N

® 

Analog Vario

 contains no environmentally harmful components. When the 

product's service life is exhausted and you would like to dispose of it please do so 
in accordance with applicable legal regulations.

Содержание Analog Vario

Страница 1: ...Installation manual 2N Analog Vario v 1 6 www 2n com...

Страница 2: ...ation 2 4 Camera Installation 2 5 Extending Module Connection 2 6 Buttons Labels Insertion Replacement 2 7 Mounting Completion 3 Function and use 3 1 Programming 3 2 Full Parameter Chart 3 3 Function...

Страница 3: ...using any telephones keypad by tone dialling the password In addition to the buttons you can use a numerical keypad which is used as a code lock Using the keypad you can operate the device as a button...

Страница 4: ...plates Electronic volume and Hands Free control no need to open cover Operates on any analogue telephone line Stable line power feeding High acoustic quality Special functions includes automatic diall...

Страница 5: ...Installation manual 2N Analog Vario 5 77 Part No 9135130E Main unit 3 buttons...

Страница 6: ...Installation manual 2N Analog Vario 6 77 Part No 9135160E Main unit 3 2 buttons Part No 9135110KE Main unit 1 button keypad...

Страница 7: ...Installation manual 2N Analog Vario 7 77 Part No 9135130KE Main unit 3 buttons keypad Part No 9135160KE Main unit 3 2 buttons keypad...

Страница 8: ...Installation manual 2N Analog Vario 8 77 Part No 9135310E Info panel backlit button less panel used for the telephone directory house number etc Part No 9135181E Extender unit 8 buttons...

Страница 9: ...2 buttons Part No 9135311E Info panel name plate Replaces four name plates with one cover Enables the use of one half of the extender unit for the telephone directory opening hours etc Part No 9135301...

Страница 10: ...lemented with a camera proximity reader see later and display under preparation Additional accessories see later are needed for outdoor flush mounting purposes Installation Accessories Part No 9135331...

Страница 11: ...Installation manual 2N Analog Vario 11 77 Part No 9135361E Wall mounting box with 1 module roof Roof dimensions 129 240 41 mm W H D Wall hole 110 220 50 5 mm...

Страница 12: ...35362E Wall mounting box with 2 module roof Roof dimensions 229 240 41 mm W H D Wall hole 210 220 50 5 mm The mounting accessories are made of marine grade stainless steel For outdoor applications the...

Страница 13: ...In built colour CCD camera PAL resolution 420 TV rows sensitivity 2 lux Camera can be built in any basic unit In the case of poor light the camera switches into the monochrome mode automatically Supp...

Страница 14: ...and breaking contact option time unlimited switching up to 48 V 2 A Additional switch with exit button feature 9135251E NO NC contacts time unlimited switching up to 48V 2A Exit button time adj 1 6 se...

Страница 15: ...o telephone connection made e g by a pressing a button Incoming call telephone 2N Analog Vario connection Programming mode 2N Analog Vario programming mode accessible from by dialling into the interco...

Страница 16: ...Safety Always abide by this information to prevent persons from injury Warning Always abide by this information to prevent damage to the device Caution Important information for system functionality...

Страница 17: ...ion 2 1 Before You Start Product Completeness Check Please check the contents of your delivery 1 2N Analog Vario unit 1 Quick installation guide 1 User Manual on a CD 1 Hexagonal wrench 2 5 1 Transpar...

Страница 18: ...areas with a low relative air humidity e g hallways offices and other heated rooms Indoor areas where humidity condenses on walls but never flows down the walls porches storage areas industrial areas...

Страница 19: ...ording to the template included in the 2N Analog Vario supply Insert the included dowels in the wall holes electric lock is switched The product is not designed as a burglar protection device except w...

Страница 20: ...e lower part of the metal cover and fold out the cover Use a cross head screwdriver to remove the plastic cover and demount the cover Warning Never remove the main board or camera electronics from und...

Страница 21: ...pply cables Ethernet lock power cables to the basic module box through one of the holes Seal the screw hole carefully with some cement or non aggressive silicone to avoid water infiltration While inst...

Страница 22: ...ly inside and that none of them obstructs a perfect cover closure Make sure that the three loudspeaker holder feet fit into the board holes Keep the required loudspeaker position to make the seal work...

Страница 23: ...n the top groove of the plastic cover A spare seal package is included Close the metal cover and fix it with screws Outdoor Installation Rules Always connect button backlighting it is used for heating...

Страница 24: ...be connected to an analogue line or the GSM interface providing a wireless installation Connection to Telephone Line Connect 2N Analog Vario simply using LINE terminals The advantage is that 2N Analog...

Страница 25: ...tions Microphone connector Keypad connector Extension unit connector Serial number Main microprocessor Configuration jumper block Right connector Jumpers Camera connector Camera setting jumpers Loudsp...

Страница 26: ...with arbitrary polarity The power supply can feed the electric lock too LINE These two terminals are connected to the analogue telephone line with any polarity VIDEO Video signal output used only if...

Страница 27: ...to the instructions enclosed to the camera unit Parallel Connection Parallel connection of multiple telephone sets was commonly used in the era in which telephone lines were rare It carries unnecessar...

Страница 28: ...supplied The ac supply is more advantageous because the lock buzzes which is the clearest signalling method however to use a dc supply lock from batteries e g you are recommended to equip 2N Analog Va...

Страница 29: ...ntioned currents are maximum values at 12V Cable Arrangement inside the Cover We recommend you to use a UTP cable 8 wire approx 5 5 mm output diameter for 2N Analog Vario connection Push the cable int...

Страница 30: ...uminate the button backlight see the figure below Other reasons for such connection are the effort to minimise consumption from the back up supply which supplies the lock not the backlight or just tha...

Страница 31: ...y in a chain pattern every additional unit is connected with the previous one Each extending module has two connectors an input connector for connection towards the 2N Analog Vario basic unit and an o...

Страница 32: ...nection to Basic Unit Caution Extension modules must be interconnected by mounting jumper tunnel delivered together with each extension unit This part is made from conductive plastic If it is necessar...

Страница 33: ...on manual 2N Analog Vario 33 77 Maximum Count of Extenders 9135181E 1 8 buttons 6 5 4 3 2 1 0 9135182E 2 8 buttons 0 0 1 1 2 2 3 The table above shows how to combine modules with single whole and doub...

Страница 34: ...log Vario metal cover To do this use a hexagonal key unscrew the screw as shown in the figure and take the cover off Caution Installing the info panel name plate order No 9135311E into any of the exte...

Страница 35: ...e Insert the labels printed on foil see later Replace the name plate inserts Put the name plates back in the depression and click into position The name plates keep the matt foil steady Replace and sc...

Страница 36: ...nted with a laser printer Cut the printed foil into pieces and insert the labels into the name plates Do not use paper to avoid water logging Make sure that the text does not cover up the red arrows p...

Страница 37: ...r and find the obstacle Then tighten the corner screws properly Mounting the metal cover follow the steps included in the subsection dedicated to name plate removal Make sure that the cover fits well...

Страница 38: ...Installation manual 2N Analog Vario 38 77...

Страница 39: ...Installation manual 2N Analog Vario 39 77...

Страница 40: ...g the programmed numbers for correctness All parameters are stored safely in the non volatile EEPROM memory The memory capacity does not limit the count or length of numbers passwords etc This means t...

Страница 41: ...and 822 individually The default status is a single password in the list namely 00 for switch 1 and 11 for switch 2 These two special passwords cannot be entered from the 2N Analog Vario keypad To can...

Страница 42: ...t Deleting All Passwords All Memories Complete Initialisation The following three functions facilitate your programming by clearing all previous settings 997 deletes the entire password list for both...

Страница 43: ...1 to 546 All button memories Up to16 digits blank Note 1 The 02x parameter is always programmed for the singlebutton model 2N Analog Vario Digits 0 9 can only be entered directly into the memories Spe...

Страница 44: ...12 Delete valid switch 1 passwords Valid pass word Deletes individual valid switch 1 passwords 822 Delete valid switch 2 passwords Deletes individual valid switch 2 passwords 813 Switch 1 closing time...

Страница 45: ...ll is from the intercom 911 Count of rings before incoming call answering 1 99 2 Warning No connection is established if a higher value is entered than as allowed in the PBX ringing timeout 912 Max ca...

Страница 46: ...Reception volume 0 15 7 15 Maximum reception volume 934 Transmission volume 0 15 7 15 Maximum transmission volume 935 Message volume 0 15 7 15 Maximum message volume 936 Beeping volume 0 12 12 12 Max...

Страница 47: ...duration 0 255 70 0 7s 944 Maximum tone pause difference 0 255 10 0 1s 945 Minimum count of busy tone periods 2 9 4 946 Dual tone detection setting 0 10 4 440 Hz All continuous busy and ringing tones...

Страница 48: ...10 100 60 6 s 954 Count of ringing periods 1 99 10 If the preset count of periods is exceeded the call is terminated If the preset count of periods is exceeded and automatic dialling is enabled anothe...

Страница 49: ...ber 16 digits The number enables intercom identification 975 Message options for automatic multiple number dialling 2 digits 55 1st digit type of message repeated after dialling 2nd digit type of mess...

Страница 50: ...r function Parameter Name Range Default Note 976 language selection for a message 0 8 1 0 1 English 2 3 4 German 5 7 8 Portuguese 9 Dutch10 99 silence Note See Survey of messages in Subs 4 2 Caution C...

Страница 51: ...memories 12345 Clears memories 01 to 55 999 Full initialisation 12345 Warning Changes the service password too setting the default value of 12345 Notes Terminology For the purpose hereof parameter mea...

Страница 52: ...ke switch 2 activate automatically with a defined delay if switch 1 is activated Useful where two doors are close to each other The numbers in the figure are parameter numbers The parameters can be se...

Страница 53: ...2N Analog Vario unit is connected to a telephone system you may be able to tag the port that 2N Analog Vario is connected to so that you can see on the ringing phone that it is 2N Analog Vario that is...

Страница 54: ...hes program 2N Analog Vario see later and listen to what is going on outside and speak to the calling party if desired Door opening 2N Analog Vario contains a switch to which an electric lock can be c...

Страница 55: ...o the door opening sound etc until the switch is deactivated Upon deactivation you can hear the storing signal see the Signals Overview Call extension 2N Analog Vario beeps 10 seconds before the call...

Страница 56: ...ard from the loudspeaker after line connection first connection signalling Signals an incoming call if 2N Analog Vario has not been programmed When a disabled function has been entered from the keypad...

Страница 57: ...lapsed A 2N Analog Vario button was pressed during the call The keypad button was pressed during the call can be disabled The communicator is able to detect a permanent tone busy tone and ringing tone...

Страница 58: ...F Transmission during Outgoing Call This function enables the unit to transmit DTMF tones when the connection with one of the pre programmed numbers has been established It is used in combination with...

Страница 59: ...or opening code lock Enter any valid password for switch 1 and Warning Password 00 may not be used Switch 2 activation Enter any valid password for switch 2 and Warning Password 11 may not be used Tra...

Страница 60: ...tches be activated at the same time While one switch is activated the other can be activated by another password You can also use parameter 824 Switch 2 delay defining the shortest delay time possible...

Страница 61: ...or ringing tone Y Y Y Y Switch activation DTMF password Programming start Y Keyboard letters facilitate password remembering For example it is easier to remember a 9 letter word e g crocodile than a...

Страница 62: ...pulse dialling is selected it is possible to switch into tone dialling by pressing but not vice versa 3 4 Section for Advanced Users Automatic Multiple Number Dialling When you press a 2N Analog Vari...

Страница 63: ...tiple Number Dialling without Confirmation This mode can be used in common cases to enable the visitor to get through even if the called line is busy or the called subscriber is absent Hence the secon...

Страница 64: ...e Regarded as a successful call continues for the maximum timeout maximum call duration For details refer to the text under the table Ringing tone 10 rings are made the count of rings is variable Hang...

Страница 65: ...he next number in the sequence Evaluation of Situations in Audible Automatic Dialling with Confirmation Situation 2N Analog Vario Action Busy tone Hangs up in approximately 2 seconds and dials the nex...

Страница 66: ...Identification There are situations in which the calling person does not want to or cannot speak for security reasons in the automatic dialling mode In these cases 2N Analog Vario can play back a mes...

Страница 67: ...ntil the end of timeout and any of the following commands can be used Message muting during playback Warning You may not speak while 2N Analog Vario is playing back the message Message re plays once o...

Страница 68: ...e of parameter 976 Language selection English version End of call message Outgoing call message ID message Parameter 975 must contain digit 2 3 or 5 Confirmation message Parameter 975last digit 5 0 To...

Страница 69: ...ture Arrival passwords How does switching work Every button has memories for 6 numbers intended primarily for Automatic Multiple Number Dialling If the Automatic Multiple Number Dialling mode is OFF m...

Страница 70: ...ful Mrs Johnson s mobile phone 3 5 Maintenance Cleaning If used frequently 2N Analog Vario especially the keypad gets dirty To clean it use a piece of soft cloth moistened with clean water We recommen...

Страница 71: ...Installation manual 2N Analog Vario 71 77 3 6 Downloads Templates Nametags...

Страница 72: ...8 V 16 V I 25 mA I 50 mA Lead current while hang up 25 A U 60 V Off hook AC impedance 220 820 115 nF parallel 20 to 60 mA Return loss 10 dB 20 to 60 mA Bandwidth 300 to 3500 Hz 20 to 60 mA Ringing im...

Страница 73: ...ction speed Variable 350 to 500 Hz Overvoltage protection common mode 1000 V 8 20 s Overvoltage protection between A B conductors 1000 V 8 20 s Other Parameters Switch max voltage 48 V AC DC Switch mi...

Страница 74: ...Installation manual 2N Analog Vario 74 77 4 1 Obecn v kresy Surface mounting Flush mounting...

Страница 75: ...nstructions and recommendations included herein Any use of the product that is in contradiction with the instructions provided herein may result in malfunction damage or destruction of the product The...

Страница 76: ...software protection of the product The manufacturer shall not be held liable and responsible for any damage incurred as a result of the use of deficient or substandard security software The consumer s...

Страница 77: ...Installation manual 2N Analog Vario 77 77...

Отзывы: