Installation manual 2N® IP Vario
81
/
113
•
•
•
•
•
Specifications:
Passive switch: NO and NC contacts, up to 30 V / 1 A AC/DC
Switched output:
Where the security relay is fed from the intercom, 9 to 13 V DC is available on the output
depending on the power supply (PoE: 9 V; adapter: source voltage of minus 1 V) / 400 mA
DC.
Where the security relay is fed from an external power supply, 12 V / 700 mA DC is available
on the output.
Dimensions: (56 x 31 x 24) mm
Weight: 20 g
Installation:
Install
the
2N
®
Security Relay
onto
a two-wire cable between the intercom and
the electric
lock
inside the area to be secured (typically behind the door). The device is
powered and
controlled
via this two-wire cable and so can be added to an existing installation.
Thanks to
its compact
dimensions, the device can be installed into a standard mounting box.
Connection:
Connect
the
2N
®
Security Relay
to
the intercom as follows:
To the intercom active output (OUT1)
Connect the electric lock to
the
2N
®
Security Relay
output
as follows:
To the switched output.
To the passive output in series with the external power supply.
The device also supports a Departure button connected between the
‘PB’
and
‘-
HeliosIP/IP
Intercom’ terminals.
Press the Departure button to activate the output for 5 seconds.
Содержание 9137111CKU
Страница 1: ...Installation manual 2N IP Vario v 2 16 www 2n com ...
Страница 51: ...Installation manual 2N IP Vario 51 113 Description of Connectors PCB Versions 535v1 535v2 ...
Страница 52: ...Installation manual 2N IP Vario 52 113 Description of Connectors PCB Versions 535v5 ...
Страница 53: ...Installation manual 2N IP Vario 53 113 Description of Connectors PCB Versions 535v8 ...
Страница 85: ...Installation manual 2N IP Vario 85 113 Connection ...
Страница 108: ...Installation manual 2N IP Vario 108 113 Flush mounting ...
Страница 113: ...Installation manual 2N IP Vario 113 113 ...