![2N 9137111CKU Скачать руководство пользователя страница 79](http://html.mh-extra.com/html/2n/9137111cku/9137111cku_installation-manual_439858079.webp)
Installation manual 2N® IP Vario
79
/
113
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Logical inputs
Active mode – requires external voltage (JP2 jumper OFF)
U
IN-ON
= min +2.5 V
U
IN-OFF
= max +1.5 V
U
IN max
= +48 V
I
IN
(U
IN
+48 V) = max 1 mA
Passive mode – requires external contact only (JP2 jumper ON)
U
OUT
= approx. 8.3 V
I
LOOP
= approx. 0.5 mA
Signalling outputs
5 V or 12V DC voltage
270 ohm current limiter
WIEGAND interface
Input / Output (as programmed)
Module mounting:
Power off
2N
®
IP Vario
.
Use a hexagonal wrench to unscrew and remove the metal cover.
Use a cross-head screwdriver to unscrew and remove the plastic cover.
Connect the reader module into the
2N
®
IP Vario
basic unit bottom connector making
sure that the microphone cable lies under the module.
Use the enclosed screws to fix the reader module to the
2N
®
IP Vario
plastic base.
Connect the wires for the reader module interface(s) if necessary.
Replace and fix the plastic cover using cross-head screws.
Replace and screw back the metal cover.
Module settings:
Refer to
the
Configuration manual for 2N IP intercoms
for
details.
Connection:
Содержание 9137111CKU
Страница 1: ...Installation manual 2N IP Vario v 2 16 www 2n com ...
Страница 51: ...Installation manual 2N IP Vario 51 113 Description of Connectors PCB Versions 535v1 535v2 ...
Страница 52: ...Installation manual 2N IP Vario 52 113 Description of Connectors PCB Versions 535v5 ...
Страница 53: ...Installation manual 2N IP Vario 53 113 Description of Connectors PCB Versions 535v8 ...
Страница 85: ...Installation manual 2N IP Vario 85 113 Connection ...
Страница 108: ...Installation manual 2N IP Vario 108 113 Flush mounting ...
Страница 113: ...Installation manual 2N IP Vario 113 113 ...