Installation Manual 2N® IP Style
48
/
88
2.3.1 Overvoltage Protection
Recommendations for Additional Overvoltage Protection Installation
If running:
a) outside a building,
b) on/in an outer wall or roof,
the 2N device wiring may be exposed to atmospheric effects resulting in overvoltage that may
subsequently damage any devices installed outside the building, on its outer wall or roof.
Overvoltage may damage devices connected to these wires and installed inside the building as
well. Therefore, we recommend that additional surge protectors be installed on all the wires
leading outside buildings, on outer walls or roofs, namely:
a) as close as possible to the device installed outside the building or on its outer wall/roof,
b) as close as possible to the point where the wires leave the building.
Examples of Overvoltage Protection Installation: