background image

 
 

Installation Manual 2N® IP 

Style

 

v.1.1

www.2n.com

 
 
 

 

Содержание 02407-001

Страница 1: ...Installation Manual 2N IP Style v 1 1 www 2n com ...

Страница 2: ...n 2 3 Electric Installation 2 3 1 Overvoltage Protection 2 4 Extending Module Connection 3 Function and Use 3 1 Configuration 3 1 1 2N IP Style LAN Location via 2N Network Scanner 3 2 2N IP Style User Control 3 3 Intercom Control as Viewed by Internal User 3 4 Maintenance 3 5 Downloads 4 Technical Parameters 5 Supplementary Information 5 1 Troubleshooting 5 2 Directives Laws and Regulations 5 3 Ot...

Страница 3: ...meric keypad allowing you to use the intercom as a code lock for lock switch activation or for making calls to a selected user phone virtual number Card Reader integrated card reader providing access control management using 125 kHz and 13 56 MHz optionally secured RFID cards With the advanced features functions other than the door lock can be RFID card controlled too Electric lock switch this swi...

Страница 4: ...witches with wide setting options Integrated 125 kHz and 13 56 MHz optionally secured RFID card reader LAN PoE or external 12 V 4 A power supply Configuration via device web interface SIP 2 0 and SIPS support Up to 10 000 phone book positions Up to 20 user time profiles Video codecs H 264 MJPEG Audio codecs G 711 G 729 G 722 L16 16 kHz HTTP server for configuration SNTP client for server time sync...

Страница 5: ...nd Associated Products Main Units 2N Part No 9157101 Axis Part No 02521 001 2N IP Style Main Unit Internal 125 kHz and 13 56 MHz card reader Part No 9157101 S Axis Part No 02407 001 2N IP Style Main Unit Internal 125 kHz and secured 13 56 MHz card reader ...

Страница 6: ...nstallation Manual 2N IP Style 6 88 Mounting Accessories Part No 9157002 Axis Part No 02406 001 2N IP Style surface mounting chassis Part No 9157001 Axis Part No 02405 001 2N IP Style flush mounting box ...

Страница 7: ... module The OSDP module provides communication between a connected device control panel door controller and 2N IP Verso via the OSDP The module is installed under another module i e needs no separate position Part No 9137422E 2N IP External Bluetooth reader USB interface An external Bluetooth reader connected via USB to your computer It can be used for pairing new users who want to use their smart...

Страница 8: ...wed in a single installation The maximum bus length is 7 m Part No 9155054 3 m interconnecting cable Only one interconnecting cable is allowed in a single installation The maximum bus length is 7 m Part No 9155055 5 m interconnecting cable Only one interconnecting cable is allowed in a single installation The maximum bus length is 7 m ...

Страница 9: ...ccessories Part No 91378601 2N Indoor View black Indoor answering audio video unit with a touchscreen designed for all 2N IP intercoms Part No 91378601WH 2N Indoor View white Indoor answering audio video unit with a touchscreen designed for all 2N IP intercoms ...

Страница 10: ...91378501 2N Indoor Compact black Indoor answering audio video unit with a touchscreen designed for all 2N IP intercoms Part No 91378501WH 2N Indoor Compact white Indoor answering audio video unit with a touchscreen designed for all 2N IP intercoms ...

Страница 11: ... Part No 91378401 2N Indoor Talk black Indoor answering audio unit with a touchscreen designed for all 2N IP intercoms Part No 91378401WH 2N Indoor Talk white Indoor answering audio unit with a touchscreen designed for all 2N IP intercoms ...

Страница 12: ...Installation Manual 2N IP Style 12 88 Part No 91378800 Wall plasterboard flush mounting box for 2N indoor answering units Part No 91378803 Wall surface mounting box for 2N answering units ...

Страница 13: ...0 black WiFi version second Part No 2N Indoor Touch 2 0 an elegant indoor touch panel is designed for all 2N IP intercoms The display panel shows you the person standing at your door and helps you make conversation with the visitor open the door lock or switch on the entrance hall lights Part Number 91378382 2N Indoor Touch desk stand black ...

Страница 14: ... white WiFi version second Part No 2N Indoor Touch 2 0 an elegant indoor touch panel is designed for all of the 2N IP intercoms The display panel shows you the person standing at your door and helps you make conversation with the visitor open the door lock or switch on the entrance hall lights ...

Страница 15: ...78381US The exclusive type of power adapter SYS1561 0912 to be used with all 2N Indoor Touch 2 0 devices Stabilised 12 V 0 75 A source to be used where PoE supply is unavailable The part numbers differ in their electric socket markings E GB US 2N Part No 1120101W Axis Part No 02518 001 2N IP Handset answering unit white color ...

Страница 16: ...imple operation HD quality video calls A display equipped extender EXP50 Part No 91378363 can be added to the phone delivery to make up to 60 speed dialings 2N Part No 1120111EU Axis Part No 02544 001 Grandstream GXV3350 IP video phone Android 7 0 OS 5 touch display control HD quality video calls WiFi and Bluetooth support HDMI output and pan tilt zoom camera Easy integration with intercoms or PBX...

Страница 17: ...Bluetooth support Easy integration with IP intercoms PBXs and security cameras Electric Locks Part No 932071E BEFO 11211 12 V 230 mA DC low consumption Part No 932081E BEFO 11221 with momentum pin 12 V 230 mA DC low consumption A very short electric pulse is enough to put the lock into the OPEN position and unlock the door After passage the lock gets in the CLOSED relax position again ...

Страница 18: ...e 18 88 Part No 932091E BEFO 11211MB with mechanical blocking 12 V 230 mA DC low consumption You can set the lever mechanically into the OPEN or CLOSED position When OPEN the lock is constantly open when CLOSED it is a standard lock ...

Страница 19: ... 12 V 170 mA DC The reversible lock is closed when electricity is switched on When electricity is interrupted the lock is opened Part No 932062E BEFO 321211 reversible plus door signaling 12 V 170 mA The reversible lock is closed when electricity is switched on When electricity is interrupted the lock is opened It contains a built in contact to indicate whether the door is open closed Tip FAQ Elec...

Страница 20: ... 88 Power Supply Part No 91378101 PoE injector For intercom supply via the Ethernet cable where the PoE switch is absent Part No 932928 12 V transformer For 230 V mains voltage For external power supply of the lock with 12 V AC voltage ...

Страница 21: ... any IP device to it You do not have to configure anything all you need is one 2N 2Wire unit at each end of the cable and a power supply connected to them 13 MHz RFID Part No 9159031 External 13 56 MHz RFID card reader Wiegand Secondary reader for connection to an internal reader It provides card access control from both sides of the door IP68 cover also suitable for exteriors Card types ISO14443A...

Страница 22: ...erface Suitable for system administration and adding of 13 56 MHz 125 kHz cards and Android platform devices supporting NFC HCE using the 2N IP intercom web interface or 2N Access Commander The same card device types are read as in the 2N IP intercom card readers 125 kHz EM4xxx 13 56 MHz ISO14443A Mifare DESFire PicoPass HID iClass FeliCa ST SR IX 2N Mobile Key ...

Страница 23: ... and adding of 13 56 MHz 125 kHz cards and Android platform devices supporting NFC HCE using 2N IP intercom web interface or the 2N Access Commander application The same card device types are read as in the 2N IP intercom card readers 125 kHz EM4xxx 13 56 MHz ISO14443A Mifare DESFire PicoPass HID iClass FeliCa ST SR IX 2N Mobile Key HID SE Seos iClass SE Mifare SE Part No 9134173 Mifare Classic 1k...

Страница 24: ...ndary reader for connection to an internal reader It provides card access control from both sides of the door IP68 cover also suitable for exteriors Reads EM4xxx cards Part No 9137420E 125 kHz USB RFID card reader External RFID card reader connectable to a PC via a USB interface Suitable for system administration and adding of EM4xxx cards using 2N Access Commander ...

Страница 25: ...0 125 kHz Part No 9134166E Key fob RFID type EM4100 125 kHz Biometry Part No 9137423E 2N IP intercom external fingerprint reader USB interface Used for scanning user fingerprints into the device system in case an extending fingerprint reader module is connected to 2N IP Style ...

Страница 26: ...t is also supplied and the lock to be controlled Part No 9137410E External IP relay 1 output A stand alone IP device which can be controlled from an IP intercom via HTTP commands Helps control devices from an unlimited distance Part No 9137411E External IP relay 4 outputs PoE A stand alone IP device which can be controlled from an IP intercom via HTTP commands Helps control devices from an unlimit...

Страница 27: ...rk I O relay module Lift control relay module for up to 8 floors Sensors and Switches Part No 9159013 Departure button Connects the logic input for door unlocking from inside the building Part No 9154004 Water proof metal button suitable for the internal RFID card reader ...

Страница 28: ...ct whether the door is not closed or forced open Device Protection Part No 9159011 Wiegand Isolator The 2N Wiegand isolator is designed for galvanic isolation of two separately supplied devices interconnected via a Wiegand bus The 2N Wiegand isolator protects the interconnected devices against communication errors and or damage License Part No 9137905 Enhanced Audio Part No 9137906 Enhanced Video ...

Страница 29: ...07 Enhanced Integration Part No 9137908 Enhanced Security Part No 9137909 Gold Part No 9137910 InformaCast Part No 9137915 NFC Part No 9137916 Lift Module Tip Refer to the Configuration Manual for 2N IP Intercoms Subs 3 2 Function Licensing for details ...

Страница 30: ...utor for more accessories and recommendations Safety Always abide by this information to prevent persons from injury Warning Always abide by this information to prevent damage to the device Caution Important information for system functionality Tip Useful information for quick and efficient functionality Note Routines or advice for efficient use of the device ...

Страница 31: ...ckage complies with the following list 1x 2N IP Style 1x Brief Manual 1x Certificate of Ownership 2 2 Mechanical Installation 2N IP Style is designed for surface or flush mounting Additional accessories are required for each type of installation which are not part of the main unit package The recommended height is 100 150 cm for standard installations and 100 120 cm for disabled persons from the f...

Страница 32: ...Installation Manual 2N IP Style 32 88 2N IP Style Main Unit Installation ...

Страница 33: ... down to the lowest possible position anchoring the device by snapping it into place 2A Connect all the cables to the device 2B The mounting bracket provides sufficient support for cable installation and so it is unnecessary to support the device in any way After connecting and securing the superfluous cabling in the clips 3A screw the connector cover back on 3B fold in the device towards the chas...

Страница 34: ...rcom circuits are constantly under voltage and water infiltration causes an electro chemical reaction The manufacturer s warranty shall be void for products damaged in this way Caution Make sure that the diameters of the dowel holes are accurate If the diameters are too large the dowels may get loose Use the mounting glue to secure the dowels if necessary Make sure that the depths of the dowel hol...

Страница 35: ... 35 88 Warning We do not recommend that 2N IP Style be installed on sites exposed to long time direct sunlight to avoid overheating Once overheated the device is switched off and will be switched on automatically after it gets colder ...

Страница 36: ... The recommended length of the accessible cables is 35 cm 1 Insert the dowels in the holes drilled and use the screws to anchor the chassis 2 Put the brackets to the left and right sides of the support handle and fit their positions using screws 3A Fit the lock counterparts to the upper chassis part hang the handle with the brackets to the bottom part 4B and fit all the components using screws 3C ...

Страница 37: ...Installation Manual 2N IP Style 37 88 2 2 2 Mounting Box Installation Mounting Box Installation ...

Страница 38: ...ges are aligned with the wall surface If the hole is convenient anchor the box using screws and dowels 1 Insert the enclosed detents in the riveting nuts Make sure that the tops of the detents direct towards the box center against each other The detent with 2 handles is intended exclusively for the box bottom installation Fit the detents with screws 2 If the position of the detents seems to be too...

Страница 39: ...er supply or from a PoE 802 3at supporting LAN External Power Supply For reliability reasons use a 12 V 15 SELV supply dimensioned to the current consumption as required for feeding of the main unit and connected extending modules DC voltage V Load A Max power W 12 3 36 12 4 48 PoE Supply 2N IP Style is compatible with the PoE 802 3at technology and can be supplied directly from the LAN via compat...

Страница 40: ...l functionality as it only offers a limited mode Low Power Mode for basic configuration This way of feeding is not recommended Connect the device to a PoE supply or a convenient DC supply and restart the device The PoE power supply detection is performed during the device restart If the PoE power supply is used and the Low Power Mode is on all configuration sections show a feeding problem warning ...

Страница 41: ...er Consumption 5 925 33 66 39 61 LAN Connection 2N IP Style is connected to the Local Area Network LAN via the UTP STP cable Cat 5e or higher terminated with an RJ 45 LAN connector As the device is equipped with the Auto MDIX function you can use either the straight or crossed cable version Caution We recommend the use of a LAN surge protection We recommend that an SSTP Ethernet cable with a shiel...

Страница 42: ...tatus LED LAN LAN connection status LED VBUS Bus connector Grounding terminal IN1 IN2 IN3 Input terminals in passive active mode 30 V to 30 V DC OFF open contact OR UIN 1 5 V ON closed contact OR UIN 1 5 V Tip Remove the protective connector cover to facilitate the threading of the UTP STP cable RJ terminal into the device box ...

Страница 43: ... active output RELAY 30 V 1 A AC DC NO NC contact terminals POWER 12 V 4 A External 12 V 4 A DC power supply terminals LAN connector Optionally PoE 802 3at for device LAN connection Tamper Switch Switch detecting unauthorized device opening SD CARD SD card slot Caution We recommend that a grounding cable of the cross section of 1 5 mm2 is used ...

Страница 44: ... output 8 to 12 V DC according to power supply PoE 10 V adapter source voltage minus 2 V up to 600 mA I O Module Part No 9155034 ext relay1 Passive switch make and break contact up to 30 V 1 A AC DC Used for connection of non critical devices only lights e g ext relay2 Passive switch make and break contact up to 30 V 1 A AC DC Used for connection of non critical devices only lights e g You can use...

Страница 45: ...ual 2N IP Style 45 88 Tip Relay output wiring diagram Wiring diagram for making of the electric circuit of the device to be controlled Wiring diagram for breaking of the electric circuit of the device to be controlled ...

Страница 46: ... IN1 connector in passive mode Security The 12V output is used for lock connection If however the unit 2N IP Intercom 2N Access Unit is installed where unauthorized tampering may happen building envelopes we strongly recommend that 2N Security Relay Part No 9159010 be used for enhanced installation security ...

Страница 47: ... is connected e g a relay electromagnetic lock it is necessary to protect the intercom output against voltage peak while switching off the induction load For this way of protection we recommend a 1 A 1000 V diode e g 1N4007 1N5407 1N5408 connected antiparallel to the device ...

Страница 48: ...vices installed outside the building on its outer wall or roof Overvoltage may damage devices connected to these wires and installed inside the building as well Therefore we recommend that additional surge protectors be installed on all the wires leading outside buildings on outer walls or roofs namely a as close as possible to the device installed outside the building or on its outer wall roof b ...

Страница 49: ...e Connection The 2N IP Style functions can be extended by connecting any of the available 2N IP Verso extending modules via the VBUS connector Choose the proper accessories for each type of extending module installation Info Panel 125 kHz RFID card reader 13 56 MHz NFC RFID card reader ...

Страница 50: ... the bus is irrelevant And it also irrelevant which bus connector on the module is used as the input and which is used as the output The modules include a 220 mm long interconnecting cable the Wiegand 9155037 and I O 9155034 modules include an 80 mm long bus cable It is possible to order separate bus cables of the length of 1 m 3 m or 5 m Part No 9155050 9155054 9155055 respectively which are inte...

Страница 51: ...geable and can be used either as inputs from the basic unit or outputs to other modules If this module is the last one on the bus one of the connectors remains unconnected The module package includes a 220 mm long interconnecting cable Name tag dimensions 69 2 W x 86 7 H mm dimensional tolerance 0 0 5 mm Refer towww 2n com for the printing template 125 kHz RFID Card Reader Module The 125 kHz RFID ...

Страница 52: ...The module package includes a 220 mm long interconnecting cable The following RFID cards can be read EM4xxx Caution We recommend that the M Bus and LAN cables are not crossed but carried separately through one bushing to increase the reading distance of this reader if combined with a touch display in a single installation ...

Страница 53: ...N IP Verso system elements and is used for reading secured RFID card IDs in the 13 56 MHz band The module contains two 2N IP Style bus connectors These two connectors are fully interchangeable and can be used either as inputs from the basic unit or outputs to other modules If this module is the last one on the bus one of the connectors remains unconnected The module package includes a 220 mm long ...

Страница 54: ...e last one on the bus one of the connectors remains unconnected The module package includes a 220 mm long interconnecting cable The following RFID cards can be read 125 kHz EM4xxx 13 56 MHz ISO14443A Mifare DESFire PicoPass HID iClass FeliCa ST SR IX 2N Mobile Key Tip To accelerate access card reading you are recommended to select the card types used by the user in the module settings ...

Страница 55: ...s two 2N IP Style bus connectors These two connectors are fully interchangeable and can be used either as inputs from the basic unit or outputs to other modules If this module is the last one on the bus one of the connectors remains unconnected The module package includes a 220 mm long interconnecting cable The following RFID cards can be read 125 kHz EM4xxx 13 56 MHz ISO14443A Mifare DESFire Pico...

Страница 56: ...two 2N IP Style bus connectors These two connectors are fully interchangeable and can be used either as inputs from the basic unit or outputs to other modules If this module is the last one on the bus one of the connectors remains unconnected The module package includes a 220 mm long interconnecting cable The module uses the 2 4 GHz frequency IDs from the following Bluetooth 4 0 supporting smartph...

Страница 57: ... without limitation Fingerprint Scanner Module The Fingerprint scanner Part No 9155045 is one of the 2N IP Verso system elements and is used for verification of human fingerprints for access control and intercom third party equipment control The module contains two 2N IP Style bus connectors These two connectors are fully interchangeable and can be used either as inputs from the basic unit or outp...

Страница 58: ...ns unconnected The module package includes a 80 mm long interconnecting cable The inputs outputs are addressed as follows module_name input output_name e g module5 relay1 Configure the module name in the Module name parameter in Hardware Extending modules Caution A higher moisture may deteriorate the finger papillary line scanning You are advised to dry your finger and the reader scanning surface ...

Страница 59: ...ith accessible 30 V 1 A AC DC NO NC contact IN1 IN1 terminals for input in passive active mode 30 V to 30 V DC OFF open contact or UIN 1 5 V ON closed contact or UIN 1 5 V IN2 IN2 terminals for input in passive active mode 30 V to 30 V DC OFF open contact or UIN 1 5 V ON closed contact or UIN 1 5 V TAMPER Tamper switch 9155038 input ...

Страница 60: ...Control Panel used for connection to the security PBX access system to which the intercom sends the card number information The module contains two 2N IP Style bus connectors These two connectors are fully interchangeable and can be used either as inputs from the basic unit or outputs to other modules If this module is the last one on the bus one of the connectors remains unconnected The module pa...

Страница 61: ...A Control Panel U IN U input 5 to 15 V DC for WIEGAND OUT power supply W0 OUT W1 OUT GND2 Isolated 2 wire WIEGAND OUT LED IN negated Isolated input for open LED IN input activated by GND2 connection LED IN Isolated input for open LED IN input activated by U connection G UIN WIEGAND OUT active supply LED indicator TAMPER Tamper switch Part No 9155038 input ...

Страница 62: ...s Recommended reader bus driver wiring diagram Recommended reader wiring diagram with OC output OSDP Module The OSDP module Part No 91550371 is one of the 2N IP Verso modules and provides communication between a connected device control panel door controller and 2N IP Verso via the OSDP The OSDP module provides secure sending of such access data as the access card ...

Страница 63: ...other modules If this module is the last one on the bus one of the connectors remains unconnected The module package includes a 80 mm long interconnecting cable The module also includes Isolated OSDP bus Power and pairing mode signaling LED Tamper switch 9155038 input Installation Procedure Having connected the OSDP module to 2N IP Verso via the VBUS connect the OSDP device to the module The OSDP ...

Страница 64: ... installation mode is signaled by a LED fast blinking on the OSDP module Tamper Switch Module The Tamper switch module Part No 9155038 is one of the 2N IP Verso system elements and helps secure the system against tampering The module contains two switches which open whenever the front frame is removed One switch leads directly to the terminal board and is connected to an external security exchange...

Страница 65: ...red area and the electric lock inside the secured area 2N Security Relay includes a relay that can only be activated if the valid opening code is received from the intercom Specifications Passive switch NO and NC contacts up to 30 V 1 A AC DC Switched output Where the security relay is fed from the intercom 9 to 13 V DC is available on the output depending on the power supply PoE 9 V adapter sourc...

Страница 66: ...t To the passive output in series with the external power supply The device also supports a Departure button connected between the PB and HeliosIP IP Intercom terminals Press the Departure button to activate the output for 5 seconds Status Signaling Green LED Red LED Status flashing off Operational mode on off Activated output flashing flashing Programming mode waiting for initialization on flashi...

Страница 67: ...ialization 2N Security Relay will pass into the operational mode the green LED is flashing Connection Caution Having reset the factory defaults on a device with firmware 2 18 or higher remember to reprogram 2N Security Relay using the instructions above Tip FAQ 2N Security Relay device description and use with the 2N IP intercoms Tip Video Tutorial Security Relay Installation and Configuration ...

Страница 68: ...2N IP Style is set to the dynamic IP address mode it retrieves the IP address automatically if there is a properly configured DHCP server in the LAN If no DHCP is available 2N IP Style can be operated in the static IP address mode Refer to the Configuration Manual for 2N IP Intercoms for the 2N IP Style configuration details If your device remains inaccessible you have forgotten the IP address or ...

Страница 69: ...eb interface in the System Maintenance section No configuration change appears after the restart Factory Default Reset Located among the main unit connectors the CONTROL button helps you reset the factory default values Follow the instructions below to reset the factory default values Disconnect the device from the power supply Press and hold the CONTROL button Connect the device to the power supp...

Страница 70: ...Installation Manual 2N IP Style 70 88 Caution If 2N IP Style is supplied from an external power source using terminals the factory reset is performed only if the device is disconnected from the LAN too ...

Страница 71: ...ner Description The application helps find the IP addresses of the 2N devices in the LAN Download the app from the 2N web sites www 2n com Make sure that Microsoft NET Framework 2 0 is installed for successful app installation Run the 2N Network Scanner installer Use the Setup Wizard for successful installation Setup Wizard of 2N Network Scanner Having installed 2N Network Scanner start the applic...

Страница 72: ... Select Browse to open the 2N IP Style administration web interface login window for configuration To change the device IP address select Config and enter the required static IP address or activate DHCP The default configuration password is 2n If the found device is grey highlighted its IP address cannot be configured using this application In that case click Refresh to find the device again and c...

Страница 73: ...isplay a presentation or the company logo address see Subs 5 3 8 Display of the Configuration Manual for IP Intercoms Touch any part of the display to cancel the Sleep mode and display the home page Sleep Mode Home Page The home page displays the group user name list to be called Use the icon to display a full text array to retrieve contacts in the device directory Also the possibility to enter th...

Страница 74: ...as a set of cards refer to Subs 5 3 8 Display of the Configuration Manual for IP Intercoms The user groups are superior to the users the list is arranged in the alphabetical order Press to display a full text array to retrieve a user by entering a few letters representing the user name All options are displayed from the list that contain the searched string Procedure Touch the screen with your fin...

Страница 75: ...IP Style is equipped with a door unlocking switch To activate this switch tap a valid card or chip on the integrated card reader Remember to complete the user access card ID refer to Subs 5 2 1 Users of the Configuration Manual for IP intercoms to get an RFID card chip access Procedure Tap a valid RFID card chip on the integrated card reader located in the bottom part of the device whose symbol is...

Страница 76: ... mode motion has to be detected by the intercom camera to activate the switch Arrival in the proximity or waving of the hand will do Card mode move your smartphone close to the integrated RFID card reader to activate the switch A valid authentication is notified visually and by a continuous switch activation tone or a predefined unlocking user sound An invalid authentication is signaled acoustical...

Страница 77: ...ng Switch Activation by Code 2N IP Style is equipped with a door unlocking switch Enter the valid code refer to Subs Hardware Switches of the Configuration Manual using your phone keypad to activate this switch Procedure Enter the switch 1 or 2 activating code using your phone keypad and press for confirmation Confirmation is unnecessary if the Lock code without confirmation is enabled refer to th...

Страница 78: ...F based door opening Anticovid To disinfect the surface of the device against bacteria and viruses Anti Covid and maintain the hygienic conditions of critical surfaces and touch points we recommend that you use the Zoono Microbe Shield Surface Sanitiser spray Warning Prevent water from getting inside the intercom Do not use alcohol based cleaners Avoid peroxide based cleaners Do not use lye based ...

Страница 79: ...Installation Manual 2N IP Style 79 88 3 5 Downloads Software 2N USB driver 2N IP Eye 2N Network Scanner ...

Страница 80: ...ophones Amplifier 2 x 4 W class D amplifier Speaker 2 x 4 W 4 Ω Sound pressure level SPL max 85 dB for 1 kHz distance 1 m Output LINE OUT 1 VRMS 600 Ω Volume control adjustable with automatic adaptive mode Full Duplex yes AEC Speech transmission index STI 0 89 Audio stream Protocols RTP RTSP SRTP Codecs G 711 G 729 G 722 L16 16kHz ...

Страница 81: ...tion up to 2560 H x 1920 V 4 3 max QHD 16 9 Frame rate up to 30 frames per s Sensor sensitivity 14000 V lux sec View angle 144 H 126 V Infrared light yes Sensor sensitivity without IR light 0 1 Lux 20 Focal length 1 7 mm Video stream Protocols RTP RTSP SRTP HTTP Codecs H 264 M JPEG IP camera function yes ONVIF v2 4 profile S compatible ...

Страница 82: ...40 x 480 15 fps 768 kbps 600 kbps with 661 kbps headers High quality VGA 640 x 480 30 fps 2048 kbps 1319 kbps with 1372 kbps headers MJPEG Low quality QVGA 320 x 240 10 fps quality 70 435 kbps with headers Medium quality QVGA 640 x 480 15 fps quality 85 506 kbps High quality QVGA 1280 x 960 15 fps quality 95 8 Mbps Interface Power Supply 12 V 15 4 A DC or PoE PoE PoE 802 3at LAN 10 100BASE TX s Au...

Страница 83: ... ratio 800 1 Brightness 900 cd m2 Viewing angle 85 from any direction Numeric keypad touch numeric keypad Touch buttons touch display Directory residential business for 10 000 users I O module optional External Dimension 43 W x 31 5 H x 1 5 D mm Wiegand module optional External Dimensions 43 W x 31 5 H x 1 5 D mm Mechanical properties Cover Hardened glass Body EN AW6060 Surfacing Wet coating RAL B...

Страница 84: ...mply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules NOTE These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications ...

Страница 85: ...ein Any use of the product that is in contradiction with the instructions provided herein may result in malfunction damage or destruction of the product The manufacturer shall not be liable and responsible for any damage incurred as a result of a use of the product other than that included herein namely undue application and disobedience of the recommendations and warnings in contradiction herewit...

Страница 86: ...use as well as provisions of technical standards on electric installations have to be obeyed The manufacturer shall not be liable and responsible for damage or destruction of the product or damage incurred by the consumer in case the product is used and handled contrary to the said regulations and provisions The consumer shall at its own expense obtain software protection of the product The manufa...

Страница 87: ...ler or manufacturer shall take the product back free of charge and without requiring another purchase Make sure that the devices to be disposed of are complete Do not throw battery packs into fire Battery packs may not be taken into parts or short circuited either ...

Страница 88: ...Installation manual 2N IP Style 88 88 ...