Copyright © 2022 Nortek Security & Control LLC
65
Q501
CS lack of usage notification time, in
days (0- 255)
0- 255 Days
7 Days
Reporting
52
Q502
Periodic test, in days (0-255)
0-255 Days
30 Days
Reporting
52
Q503
Programming mode entry reports to CS
Enabled
Disabled
Disabled
Reporting
52
Q504
Trouble reports to CS
Enabled
Disabled
Enabled
Reporting
53
Q505
Trouble restore reports to CS
Enabled
Disabled
Enabled
Reporting
53
Q506
Manual bypass reports to CS
Enabled
Disabled
Disabled
Reporting
53
Q507
Bypass restore reports to CS
Enabled
Disabled
Disabled
Reporting
53
Q508
Force bypass reports
Enabled
Disabled
Disabled
Reporting
53
Q509
AC loss reports to CS
Enabled
Disabled
Enabled
Reporting
53
Q510
AC restore reports to CS
Enabled
Disabled
Enabled
Reporting
53
Q511
System low battery reports to CS
Enabled
Disabled
Enabled
Reporting
54
Q512
System low battery restore reports to CS
Enabled
Disabled
Enabled
Reporting
54
Q513
RF low battery reports
Enabled
Disabled
Enabled
Reporting
54
Q514
Sensor low battery restore reports to CS
Enabled
Disabled
Enabled
Reporting
54
Q515
System disarmed reports to CS
Enabled
Disabled
Disabled
Reporting
54
Q516
System armed reports to CS
Enabled
Disabled
Disabled
Reporting
54
Q517
Alarm restore reports to CS
Enabled
Disabled
Disabled
Reporting
54
Q518
Smart test reports
Enabled
Disabled
Disabled
Reporting
55
Question
Number
Question Text
Available Settings
Factory Default
Setting
Programming
Category
Page Reference