Copyright © 2022 Nortek Security & Control LLC
43
P
anel
P
rogramming
– a
dvanced
P
rogramming
You can program a variety of settings for the 2GIG EDGE Panel. To get started, navigate to the Installer Toolbox. Then, tap
Panel Programming >
Advanced Programming > System Configuration
.
Advanced Programming
Options include:
System Configuration
Timers, Delays & Counts
Panel Configuration
Troubles
Reporting
On the left side of each option's screen are a variety of programming
questions related to how the 2GIG EDGE Panel and different system
components operate.
1 .
Highlight a question [Q### - (settings differ based on the question)].
2 .
Tap available options to adjust settings.
3 .
Tap
to move to the next question, or tap
to return to the previous
menu.
NOTE:
Ensure that the settings you program are in compliance with
all national, state, and local regulations.
NOTE:
For more in-depth information about the list of questions
available in the Panel Programming menu, see
Advanced
Programming
ADVANCED PROGRAMMING
System Configuration
This section details the Panel Programming questions.
A dagger (†) indicates a factory default setting
.
A double dagger (‡) indicates a
default setting for compliance with ANSI/SIA CP-01-2010: Control Panel Standard - Features for False Alarm Reduction
.
Q101: Change installer code
Defines the unique four-digit code for installers to use when accessing the Installer Toolbox. See
Installer Toolbox
Choose one of these options:
»
†
1561
: This is the factory default setting.
»
Enter a unique code.
If you change the Installer Code, be sure to remember it so you can access the system later. The Installer Code
must be unique from the Master User Code and all other user codes.
IMPORTANT:
To minimize the risk of unwanted persons circumventing the system, alarm dealers and professional installers are advised
to change the system’s default Installer Code to a unique one. This helps to prevent unwanted persons from gaining access to critical
programming features of the 2GIG EDGE Panel.
Q102: Security pin code length
Configures the system’s pin code length.
Choose one of these options:
»
†
4 Digits:
Installer, Master, duress and user codes will be 4 or 6 digits long.
»
6 Digits:
Installer, Master, duress and user codes will be 6 digits long.
NOTE:
If changing from 4 to 6-digit pin codes, all existing codes will be appended with “11”. The default 6-digit Installer pin code is
156111 and Master 111111.
NOTE:
When changing from 6 to 4-digit pin codes all pin codes will be truncated, removing the last 2 digits. If this action causes
conflicts, the system will prompt to resolve the conflicts. Conflicts can be resolved by defaulting the user codes or changing the existing
pin codes so that no first four digits of the pin codes are the same.