background image

7SG13 Delta P20064 FM1 Autoreclosing 

The copyright and other intellectual property rights in this document, and in any model or article produced from it 
(and including any registered or unregistered design rights) are the property of Siemens Protection Devices Ltd. 
No part of this document shall be reproduced or modified or stored in another form, in any data retrieval system, 
without the permission Siemens Protection Devices Ltd., nor shall any model or article be reproduced from this 
document unless Siemens Protection Devices Ltd. consent.  
 
While the information and guidance given in this document is believed to be correct, no liability shall be accepted 
for any loss or damage caused by any error or omission, whether such error or omission is the result of 
negligence or any other cause. Any and all such liability is disclaimed. 
 
©2010 Siemens Protection Devices Ltd. 

 
7SG13 Delta 

Protection and Control Relays 

 

 

Document Release History 

This document is issue 2010/02. The list of revisions up to and including this issue is: 

Pre release 

 

2010/02 

Document reformat due to rebrand 

2004/08 First 

issue 

 

 

 

Software Revision History 

 

 

 

 

 

 
 
 

Summary of Contents for 7SG13 Delta

Page 1: ...e be reproduced from this document unless Siemens Protection Devices Ltd consent While the information and guidance given in this document is believed to be correct no liability shall be accepted for any loss or damage caused by any error or omission whether such error or omission is the result of negligence or any other cause Any and all such liability is disclaimed 2010 Siemens Protection Device...

Page 2: ... 4 2 1 4 Manual Close 4 2 1 5 In Out Switching 5 2 1 6 Overall Control 5 2 1 7 CB Close Command pulse 5 2 1 8 CB Failed To Open and CB Failed to Close 5 2 1 9 CB Closed by Another Device 5 2 1 10 Indications 5 2 1 11 Trip and Reclose 5 2 1 12 Metering 6 2 1 13 Dead time and Reclaim Timing 6 2 1 14 Lockout 6 List of Figures Figure 1 1 Key to Functional Block Diagrams 3 2010 Siemens Protection Devic...

Page 3: ...start trip Elem Starter Elem Inhibit Elem Reset Delay c Forward Reverse Elem Char Dir Non Dir PhA Dir Blk PhaseAFwd Digital input signal status input visible to user Digital output signal output relay visible to user Digital signal not visible to user to from another element Setting block showing list of setting values with setting name Appropriate block is TRUE when setting selected other blocks ...

Page 4: ... for each of the 4 recloses 2 1 1 Protection Trip The protection element which trips the CB is used to prime and start the autoreclose sequence Internal protection elements that will start the A R are pre selected within the relay 2 1 2 Protection Starter If during a sequence the breaker is closed from another device and a fault is still on the system the starter element will be energised This is ...

Page 5: ...table to allow a range of CBs to be used The Close pulse will be terminated if any protection Starter picks up or a trip occurs This is to prevent Close and Trip Command pulses existing simultaneously A Close Onto Fault Output is given if a starter or trip picks up in the Close Pulse This can be independently wired to Lockout 2 1 8 CB Failed To Open and CB Failed to Close CB Failed To Open and CB ...

Page 6: ...he Reclose Block Delay due to a persistent Block signal not cleared At the end of the Sync Close Delay due to Synchronism not being achieved Once the Lockout condition has been reached it will be maintained until reset The following will reset lockout By a Manual Close command from fascia comms or a status input By a Reset Lockout signal provided there is no signal present that will cause Lockout ...

Page 7: ... Inputs A R In A R Out Extern A R Start Block Reclose Go To Lockout Trip And Reclose Trip and Lockout Reset Lockout Manual Close _ 1 for each status input 2 1 14 1 Specification Element Parameters The element will take the following parameters unless otherwise specified in the appropriate Diagrams and Parameters document Parameter Value tcycle Element cycle time 20 ms tsetting Timer settings Appli...

Reviews: