background image

Step 17. Enter Alarm 1 Enable/Disable Submenu

Press 

d

to display flashing 

DSBL

ENBL

.

Step 18. Enable Alarm 1 Submenu

If flashing 

ENBL

is displayed, press 

a

, if 

DSBL

is displayed,

press 

b

until 

ENBL

is displayed, then press 

d

to store and

go to the next menu item.

Step 19. Select the Deviation Control Type Submenu

Press 

d

. If flashing 

_DEV

Deviation is displayed press 

a

,

otherwise press 

b

until flashing 

_DEV

is shown. Now 

press 

d

to store and go to next menu item. 

Step 20. Select the Latched Type Submenu

Press 

d

. If flashing 

UNLT

Unlatched is displayed press 

a

,

otherwise press 

b

until 

UNLT

is displayed. 

Press 

d

to store and advance to next menu item.

Step 21. Select the Normally Open Type of Contact
Closure Submenu

Press 

d

. If flashing 

N.o.

Normally Open is displayed, 

press 

a

, otherwise press 

b

until 

N.o.

is displayed. Press 

d

to store and advance to next menu item.

Step 22. Select the Above Type of Active Submenu

Press 

d

. If flashing 

ABoV

Above is displayed, press 

a

,

otherwise press 

b

until 

ABoV

is displayed. Press 

d

to store

and advance to next menu item.

Step 23. Enable Alarm 1 at Power On (

A.P.oN

)

Press 

d

. If flashing 

ENBL

is displayed, press 

a

, otherwise

press 

b

until 

ENBL

is displayed. Press 

d

to store and

advance to next menu item.

Step 24. Enter Alarm 1 High Submenu

Press 

a

twice to skip 

ALR.L

Alarm 1 Low value. 

ALR.L

is

for below & 

ALR.H

for above.

Step 25. Set the Alarm 1 High value (

ALR.H

)

Press 

d

. Press 

b

or 

c

until value to set the display to

002.0

. Press 

d

to save.

Step 26. Enter the Alarm 2 Menu

The display will show 

ALR2

the top menu for Alarm 2.

Repeat steps from 17 to 25 to set for Alarm 2 the same
conditions as for Alarm 1.

Step 27. Skip the Loop Break Time Menu (

LOOP

)

Press 

a

to go to the 

OUT1

Output 1 Menu item.

Step 28. Configuration the Output 1 Menu 

Set Alarm 1 Disabled (Step 18) to be able to Enable
Output 1. 

Step 29. Configuration of Display Color Selection

Press 

a

until the 

COLR

Display Color Selection Menu

appears on the Display. Configure 

COLR

as 

N.CLR

/

GRN

(green), 

1.CLR

RED

(red), 

2.CLR

/

AMBR

(amber). Please

refer to the operator’s manual if needed.

For color change on Setpoints refer to Owners
Manual Section 2. 

OPERATION
Step 1. Apply Power to the Instrument

When your device is first powered up it will display the
ambient temperature (assume 75°F).

Step 2. Enter Setpoint 1 Menu

Press 

a

one time from run mode to get to 

SP1

Setpoint 1. 

Step 3. Enter the Setpoint 1 Value Submenu

Press 

d

. Display shows the previous selection of Setpoint 1.

Step 4. Change the Setpoint 1 Value 

Press 

b

or 

c

until desired value is displayed.

Step 5. Store the Setpoint 1 Value 

Set the Setpoint 1 to 10 degree higher than Process value
(SP1 = 85) and press 

d

to store, display flashes 

STRD

message and advances to 

SP2

Setpoint 2 Menu.

Step 6. Store the Setpoint 2 Value

Repeat steps 3 and 4. Set the Setpoint 2 to 5 degree higher
than Process value (SP2 =  80) and press 

d

to store,

display flashes 

STRD

message and advances to 

CNFG

Configuration Menu.

Step 7. Enter the Reading Config Menu

Press 

d

to enter 

RDG

Reading Config Menu.

Step 8. Enter the submenu items of Rdg Config Menu

Press 

d

to display 

SNSR 

Sensor submenu: Sensor selection

for Autotune, Loop, or Ramp and Soak 

°F.°C

is for

temperature and 

DRRh

is for Humidity

Step 9. Enter the submenu items of Rdg Config Menu

Press 

d

to display Temp Unit submenu: 

Step 10 Scroll thru selection for Temp Unit submenu

Press 

b

to Scroll though the available selections of the

Temperature Unit of your choice: 

°F

or 

°C

.

Step 11. Store the Temperature Unit

Press 

d

, display momentarily shows 

STRD 

the Unit has

been stored and the instrument will go automatically to the
next menu item.

Step 12. Enter the Filter Constant Submenu

Display shows 

FLTR

Filter Constant Submenu.

Step 13. Display the Filter Constant Value Submenu

Press 

d

to display the flashing, previously selected Filter

Constant.

Step 14. Scroll through available Filter Constants

Press 

b

to sequence thru Filter Constants 

0001

0002

,

0004

0008

0016

0032

0064

and 

0128

.

Step 15. Store the Filter Constant

Press 

d

momentarily to store 

0004

Filter Constant and the

instrument will automatically go to the next menu item.

Step 16. Enter Alarm 1 Menu

The display will show 

ALR1

the top menu for Alarm 1. In the

following steps we are going to enable Alarm 1, Deviation,
Unlatch, Normally Open, Active Above, Enable at power-on
and +2°F High Alarm i.e. Process Value > Setpoint 1 Value
+2°F will activate Alarm 1.

• If Analog Output Option is installed and enabled,

the controller will skip Alarm 1 Menu item to Analog
Output.

• Alarm must be DISABLED if Ramp is ENABLED.
• Alarm1 will only work for Humidity, not

Temperature.

MQS4007/1105

SPECIFICATION

SENSOR SPECIFICATIONS
Relative Humidity Accuracy/Range:

±2% for 10 to 90% RH
±3% for 0 to 10%RH and 90 to 100%RH

Non-linearity

: ±3%

Hysteresis

: ±1% RH

Response Time

:

4 sec (63% slowly moving air)

Repeatability

: ±0.1%

Resolution

: 0.03%, 12bit

Temperature Accuracy/Range*:

±1°C (±2°F) for -40 to 0°C and 80 to
123.8°C (-40 to 32°F and 176 to 254°F)
±0.5°C (±1°F) for 0 to 80°C (32 to 176°F)

*NOTE:

extended temp range is for Probe only, the

Controller’s operating temp is 0-50°C

Repeatability

: ±0.1°C

Resolution

: 0.01°C, 14 bit

METER SPECIFICATIONS
Display:

4-digit, 9-segment LED, 
• 10.2 mm (0.40")
Red, green, and amber programmable
colors for setpoint and temperature units.

Output 1

:

Relay 250 Vac @ 3 AResistive Load,
SSR, Pulse

Output 2

:

Relay 250 Vac @ 3 AResistive Load,
SSR, Pulse  

Only with -AL Limit Alarm option

Options: Communication

RS-232 / RS-485 

or

10BaseT

or

Excitation: 24 Vdc @ 25 mA

Exc. not available for Low Power Option

Line Voltage/Power:

90 - 240 Vac ±10%, 50 - 400 Hz*, 

or

110 - 375 Vdc, 

5 W

* No CE compliance above 60 Hz

Low Voltage Power Option:

12 - 36 Vdc, 

3 W**

** Units can be powered safely with 24 Vac

but No Certification for CE/UL are claimed.

Dimensions:

25.4 H x 48 W x 126.3 D mm 
(1.0 x 1.89 x 5")

Weight:

127 g (0.28 lb)

Approvals:

CE per EN61010-1:2001

Alarm 1 is designed to monitor the humidity value
around Setpoint 1 and Alarm 2 is designed to monitor
the temperature value around Setpoint 2.

DPiTH-i32 Monitor

CNiTH-i32-AL Limit Alarm

Hu Temperature

USA

MADE IN

Servicing North America:

USA:

 

 

         One Omega Drive, P.O. Box 4047

ISO 9001 Certified

 

         Stamford CT 06907-0047

 

 

         TEL: (203) 359-1660 

 

FAX: (203) 359-7700

 

 

         e-mail: [email protected]

Canada:

   

         976 Bergar

 

 

         Laval (Quebec) H7L 5A1

 

 

         TEL: (514) 856-6928 

 

FAX: (514) 856-6886

 

 

         e-mail: [email protected]

For immediate technical or application assistance:

USA and Canada:

           Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA

®

 

 

         Customer Service: 1-800-622-2378 / 1-800-622-BEST

®

 

 

         Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

®

Mexico and

  

         TEL: (001)800-TC-OMEGA

®

 

FAX: (001) 203-359-7807 

Latin American: 

         

En Español: (001) 203-359-7803 

 

 

         e-mail: [email protected]

Servicing Europe:

Benelux:

  

         Postbus 8034, 1180 LA Amstelveen, The Netherlands

 

 

         TEL: +31 20 3472121 

 

FAX: +31 20 6434643

 

 

         Toll Free in Benelux: 0800 0993344 

 

 

         e-mail: [email protected]

Czech Republic:

 

         Frystatska 184, 733 01 Karviná

 

 

         TEL: +420 59 6311899   

FAX: +420 59 6311114

 

 

         e-mail: [email protected]

France:

   

         11, rue Jacques Cartier, 78280 Guyancourt

 

 

         TEL: +33 1 61 37 29 00  FAX: +33 1 30 57 54 27

 

 

         Toll Free in France: 0800 466 342

 

 

         e-mail: [email protected]

Germany/Austria:

           Daimlerstrasse 26, D-75392 Deckenpfronn, Germany

 

 

         TEL: +49 7056 9398-0   

FAX: +49 7056 9398-29

 

 

         Toll Free in Germany: 0800 639 7678

 

 

         e-mail: [email protected]

United Kingdom:

           One Omega Drive

ISO 9002 Certified

 

         River Bend Technology Centre

 

 

         Northbank, Irlam  Manchester M44 5BD United Kingdom  

 

 

         TEL: +44 161 777 6611  FAX: +44 161 777 6622

 

 

         Toll Free in England: 0800 488 488

 

 

         e-mail: [email protected]

OMEGAnet

®

 On-Line Service

www.omega.com

Internet e-mail

[email protected]

®

®

WARRANTY/DISCLAIMER

OMEGAENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of

one (1) year

from the date of purchase. In addition to OMEGA’s standard warranty period, OMEGA Engineering will

extend  the  warranty  period  for 

four (4)  additional  years

if  the  warranty  card  enclosed  with  each  instrument  is

returned to OMEGA.

If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will
issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA,
if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply
to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing,
operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit
shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive
corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions  outside  of  OMEGA’s  control.  Components  which  wear  are  not  warranted,  including  but  not  limited  to
contact points, fuses, and triacs.

OMEGA is  pleased  to  offer  suggestions  on  the  use  of  its  various  products.  However,  OMEGA neither
assumes responsibility for any omissions or errors nor assumes liability for any damages that result from
the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA
warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO
OTHER  WARRANTIES  OR  REPRESENTATIONS  OF  ANY KIND  WHATSOEVER,  EXPRESS  OR  IMPLIED,
EXCEPT  THAT  OF  TITLE,  AND  ALL IMPLIED  WARRANTIES  INCLUDING  ANY WARRANTY OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION
OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with
respect  to  this  order,  whether  based  on  contract,  warranty,  negligence,  indemnification,  strict  liability  or
otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event
shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS:    Equipment  sold  by  OMEGAis  not  intended  to  be  used,  nor  shall  it  be  used:  (1)  as  a  “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications
or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application,
used  on  humans,  or  misused  in  any  way,  OMEGAassumes  no  responsibility  as  set  forth  in  our  basic
WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless
from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct  all  warranty  and  repair  requests/inquiries  to  the  OMEGACustomer  Service  Department.  BEFORE
RETURNING ANY PRODUCT(S)  TO  OMEGA,  PURCHASER  MUST OBTAIN AN AUTHORIZED  RETURN  (AR)
NUMBER  FROM  OMEGA’S  CUSTOMER  SERVICE  DEPA RTMENT (IN  ORDER  TO AVOID  PROCESSING
DELAYS).  The  assigned AR  number  should  then  be  marked  on  the  outside  of  the  return  package  and  on  any
correspondence.

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in
transit.  

FOR WARRANTY RETURNS, please have the
following information available BEFORE 
contacting OMEGA:
1.

Purchase Order number under which the product
was PURCHASED,

2.

Model and serial number of the product under
warranty, and

3.

Repair instructions and/or specific problems
relative to the product.

FOR NON-WARRANTY REPAIRS, consult OMEGA for
current repair charges. Have the following information
available BEFORE contacting OMEGA:
1. 

Purchase Order number to cover the COST of the
repair,

2.

Model and serial number of product, and

3.

Repair instructions and/or specific problems
relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.

OMEGAis a registered trademark of OMEGAENGINEERING, INC.

© Copyright 2005 OMEGAENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without
the prior written consent of OMEGAENGINEERING, INC.

PATENT AND TRADEMARK NOTICE: This product is covered by one or more of the following patents:  U.S. Pat.
No. Des. 336,895; 5,274,577; 6,243,021 / CANADA 2052599; 2052600 / ITALY 1249456; 1250938 / GERMANY DE
41 34398 C2 / SPAIN 2039150; 2048066 / UK Patent No. GB2 249 837; GB2 248 954 / FRANCE BREVET NO. 91
12756. The “Meter Bezel Design” is a trademark of Newport Electronics, Inc. USED UNDER LICENSE. Other U.S.
and International Patents pending or applied for.

This  device  is  marked  with  the  international  caution  symbol.      It  is  important  to  read  the
Setup Guide before installing or commissioning this device, as the guide contains important
information relating to safety and EMC.

WARNING:

These  products  are  not  designed  for  use  in,  and  should  not  be  used  for,  patient-

connected applications.

It  is  the  policy  of  OMEGAto  comply  with  all  worldwide  safety  and  EMC/EMI  regulations  that  apply.
OEMGAis constantly pursuing certification of its products to the European New Approach Directives.
OMEGAwill add the CE mark to every appropriate device upon certification.
The  information  contained  in  this  document  is  believed  to  be  correct,  but  OMEGAEngineering, Inc.
accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.

TRADEMARK NOTICE:

®

,

omega.com

®

,

and 

®

are  Trademarks  of

OMEGAENGINEERING, INC.

®

Reviews: