Economical Time Delay Relay Module

FEATURES:

Operating Voltage Range:

12

to

24

Volts D.C.

Adjustable Delay Time.

PositiveorNegativeLowCurrentTrigger.

SPDT

(Form "C") Relay.

Selectable Initial Relay State: ON / OFF.

Output Modes: One-Shot or Repeat.

LED Indication of Relay Status.

Lifetime Limited Warranty, call for details.

Packed In Reusable Poly Storage Box.

SPECIFICATIONS:

Time Settings: 1 Sec to ~ 60 Min.

Relay Contact Rating: 7A @ 30 VDC.

10A @ 125 VAC.

Operating Voltage: 12 to 24 Volts D.C.

Trigger Voltage: 4.5 - 24 Volts D.C.

Input Trigger Current: 1.2 mA.

Current Draw With Relay On: 40mA.

Size: 76x55x25mm (Fits Std.Snap Track).

Features and Specifications subject to change without notice.

Delay Timer

101-281 NESS 960

Delay Timer

NESS-960

03/04

APPLICATION:

The

NESS-960

is an economical and flexible

solution for many general-purpose time delay

applications. The unit operates on 12 to 24

Volts D.C. and can be selected for positive or

negative trigger logic. Setup is easy with

thumbwheel adjustment between 1 and 60

seconds, a quick jumper setting converts the

time from seconds to minutes. The timer can be

configured to activate once for each trigger, or

pulse as soon as power is applied.

OVERVIEW

The NESS-960 features adjustable delay time of one (1)

second to approximately sixty (60) minutes. It can be

operated by

12

to

24

volts D.C. and can be triggered

by a negative (

-

) or positive (

+

) voltage. The operating

mode and the relay condition can be set as follows:

BEGIN-

Relay turns on when triggered and back off

when delay time expires.

END

- Relay turns off when

triggered and back on when delay time expires. The

delay time can start when the trigger is first applied (

B

mode) or when the trigger is removed (

A

mode). The

NESS-960 relay can be set to provide a single

1-SHOT

output or to

REPEAT

(pulse on and off). All options

are selected using easy to change mini-jumpers.

TERMINALDESCRIPTIONS

Positive power input. Connect a +12 to +24 Volts

D.C. source.

Warning: Do not 24 Volts

D.C., Damage will occur.

Negative power (ground) input. Connect to a nega-

tive or ground terminal of the power source.

TGR

Triggervoltageinput. Connecta4.5to24VDCtrigger

source. Place jumper

JP5

(TRIGGER POLARITY) in

the "+" position to trigger from a positive voltage or

in the "-" position to trigger from a negative. The

trigger voltage may be 4.5 to 24VDC, regardless of

the main powered input (12Vdc to 24VDC).

N/O

Normally Open side of the relay contacts. No con-

nection to COM when the relay is off.

COM

Common or "pole" side of the relay contacts. When

the relay is off, COM is internally connected with the

N/C contact. When the relay is on, COM is internally

connected with the N/O contact.

N/C

Normally Closed side of the relay contacts. This

terminal is internally connected with the COM termi-

nal when the relay is off.

NOTE: The NESS-960 automatically triggers (turns on) and runs

through a delay cycle when first powered up. To reduce waiting time

and speed up installation, set jumper JP1 to SEConds and adjust R3

to 1 before applying power.  Once power is applied, change the

settings as required.

+

-

SETTINGSANDJUMPERDESCRIPTIONS

R3

This knob is used to increase or decrease the delay time

from 1 to 60. Full clockwise is 1, halfway is 30, full

counter-clockwise is 60. The arrow is a reference point.

JP1 SEC

= Delay time in seconds. Adjustable from 1 ~ 60.

1

MIN

= Delay time in minutes. Adjustable from 1 ~ 60.

1

JP2 REPEAT

= (Adjustable pulse) Relay cycles ON / OFF at

delay time interval using a 50/50 duty cycle.

2

A trigger input will temporarily stop the cycle.

1-SHOT

= Relay activates only once per trigger.

JP3 END

= Relay turns off when triggered and back on

when delay time expires.

BEGIN

= Relay turns on when triggered and back off

when delay time expires.

JP4 A

= Delay time starts when trigger is removed.

B

= Delay time starts when trigger is first applied.

JP5 +

= Selects positive polarity for the input trigger.

-

= Selects negative polarity for the input trigger.

 1 

Times are approximate. When adjusted to the highest

setting (60 minutes) the actual time delay will be slightly

greater.

HINT: For a delay time in minutes, adjust and test with

jumper JP1 in the SEConds position. (IE: For a 15 minute

delay, adjust and test to 15 seconds) Then move jumper JP1

to MINutes. This quickly provides a reasonable equivalent

delay time in minutes.

2

A 50/50 duty cycle means the OFF and ON times will be

equal.

Instructions Printed On Inside

NSW (02) 8825 9222

Vic    (03) 9875 6400

Qld    (07) 3343 7744

W.A (08) 9328 2511

S.A. (08) 8277 7255

4/167 Prospect Hwy, Seven Hills, NSW, 2147

www.ness.com.au/m1 - email: [email protected]

Reviews: