background image

 
User Manual 

 
Version 0814 
www.intelligent-appliance.com 

 

 

 

IA-3121-E 

32-ch Solid-State Relay (SSR) Board, 
Ethernet IP Controlled  
IA Series-3000 Daisy-Chain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for IA-3121-E

Page 1: ...User Manual Version 0814 www intelligent appliance com IA 3121 E 32 ch Solid State Relay SSR Board Ethernet IP Controlled IA Series 3000 Daisy Chain...

Page 2: ...y to use and 24 7 technical support Intelligent Appliance delivers services via the internet The dedicated website offers large knowledgebase database that include full information for Development Eng...

Page 3: ...6 Pin Assignment 7 User Defined Jumpers Led 7 COMMAND SET 8 AA0 GET DEVICE NAME 9 AA1 GET DEVICE FIRMWARE VERSION 10 AA2DDDDDDDD SET RELAY STATUS 11 AA3DD ACTIVATE RELAY N 13 AA4DD DE ACTIVATE RELAY N...

Page 4: ...tate Relays is incomparable Long Operation Life Fast Respond Silent Operation and best fitting Inductive Loads The IA 3121 E may be referred to as a High Power 32 ch Digital Output Module with an Open...

Page 5: ...VDC Current Consumption 0 3Amp Module Size 135x115x45 mm Weight 220gr Intelligent Appliance products are NOT authorized for use as components in life support devices or systems Do not operate the devi...

Page 6: ...tions are subject to change without notice 32 ch Solid State Relay SSR Board Ethernet IP Controlled IA Series 3000 Daisy Chain Installation System Wiring RJ45 LAN Cable RJ45 LAN Cable DB9 Female DB9 M...

Page 7: ...State Relay SSR Board Ethernet IP Controlled IA Series 3000 Daisy Chain Pin Assignment J1 Main Port LAN J2 Expansion Port RS 232 DB9 Male Pin Function 2 Tx 3 Rx 5 GND TB1 2 4 5 SSR 1 to SSR 32 TB3 Pow...

Page 8: ...d is structured from a delimiter character modules address command character data if any carriage returns character All commands must use UPPER CASE characters AA0 GET DEVICE NAME 9 AA1 GET DEVICE FIR...

Page 9: ...e specified address Syntax aa0 CR Delimiter character aa Hexadecimal address of the device 0 Get device Model command CR Carriage Return End of command Response _nnnn CR if the command was valid _ Res...

Page 10: ...limiter character aa Hexadecimal address of the device 1 Get device Version command CR Carriage Return End of command Response _nnnn CR if the command was valid _ Response delimiter nnnn A string cont...

Page 11: ...This command defines module s relay state Syntax aa2dddddddd CR Delimiter character aa Hexadecimal address of the device 2 System control command d Relay output activation command data for each nibbl...

Page 12: ...elay 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Nibble 1 2 3 4 5 6 7 8 1 1 0 1 0 1 0 1 2 1 1 0 0 1 1 0 4 1 1 1 1 1 1 0 8 1 1 1 1 1 1 1 HEX F E D C B A 9 DEC...

Page 13: ...vate relay N Description This command activates a single relay Syntax aa3dd CR Delimiter character aa Hexadecimal address of the device 3 Single relay activation command dd N Relay ID in hex format CR...

Page 14: ...7 16 15 14 13 12 11 10 F E D C B A 9 8 7 6 5 4 3 2 1 0 Relay 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1 1 0 1 0 1 0 1 2 1 1 0 0 1 1 0 4 1 1 1 1 1 1 0 8 1...

Page 15: ...vate relay N Description This command De activates a single relay Syntax aa4dd CR Delimiter character aa Hexadecimal address of the device 4 De activate relay N command dd Relay ID hex format CR Carri...

Page 16: ...15 14 13 12 11 10 F E D C B A 9 8 7 6 5 4 3 2 1 0 Relay 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1 1 0 1 0 1 0 1 2 1 1 0 0 1 1 0 4 1 1 1 1 1 1 0 8 1 1 1 1...

Page 17: ...ter aa Hexadecimal address of the device 5 System Mode command dd 8 mode control bits 00 FF Bit Function 1 Enable Error Messages 6 Disable Feedback messages on AA2 AAM Commands if BIT 7 is cleared 7 E...

Page 18: ...rd baud rates Syntax aa6dd CR Delimiter character aa Hexadecimal address of the device 6 Change device baud rate command dd Two characters representing the desired baud rate 12 1200 24 2400 48 4800 96...

Page 19: ...s address Syntax aa7dd CR Delimiter character aa Hexadecimal address of the device 7 Change device baud rate command dd New Hexadecimal address CR Carriage Return End of command Response dd CR if the...

Page 20: ...n This command sets the status of 8 relays at a time Syntax aaBndd CR Delimiter character aa Hexadecimal address of the device B Change Byte Level command n Byte to be set n is in the range of 0 3 dd...

Page 21: ...3 2 1 0 3 2 1 0 3 2 1 0 3 2 1 0 3 2 1 0 3 2 1 0 Relay 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 n 3 2 1 0 1 1 0 1 0 1 0 1 2 1 1 0 0 1 1 0 4 1 1 1 1 1 1 0...

Page 22: ...POWER UP Syntax aaEdddddddd CR Delimiter character aa Hexadecimal address of the device E System control command d Relay output activation command data for each nibble in hex format CR Carriage Return...

Page 23: ...character aa Hexadecimal address of the device M System control command d Relay output activation command data for each nibble in hex format CR Carriage Return End of command Response Mdddddddd CR if...

Page 24: ...is command forces all modules of this net into their pre defined initiate state Syntax E CR Delimiter character E Hexadecimal address of the device CR Carriage Return End of command Response No FB mas...

Page 25: ...nd forces Activate Relays per Memory Status Syntax M CR Delimiter character M Activate Relays per Memory Status CR Carriage Return End of command Response Relay state is set to memory state no feedbac...

Reviews: