3-36
3
Guard Time (S12=0-
255)
Register S12 controls the amount of time, after receiving
three escape characters, that must elapse before
entering on-line command mode and sending the OK
message to the DTE.
Default = 50 (1 second)
.
S13 Reserved
N/A
S14 Bit-mapped
N/A
S15 Reserved
N/A
S16 Bit-mapped
N/A
S17 Reserved
N/A
Test Duration
(S18=0-255)
Register S18 sets the duration of the modem’s
diagnostic tests. When S18 is set to 0, the test
continues indefinitely until stopped by the operator. To
manually stop a test, enter the +++ escape sequence,
and from online command mode issue an
AT&T0<ENTER>
command or ATH<ENTER>.
Default =
0 (indefinite)
.