FV801 Rev. A 06/21/21
Page 8
1 2 3 4 5 6 7
8
ON
OFF
To adjust features from default configuration, you must remove the
battery tray. Once battery tray is removed you will see the switches.
Purge Features:
The purge switches can be configured for 4 modes of operation: Disabled (standard configuration), 12 hour, 24 hours, or 48 hours.
Purge water flow duration is 2 minutes. Note: Purge activation occurs every switch selected time (0,12, 24, or 48 hours) after last
activation.
Flow Time:
There are 6 optional time configurations: 30 seconds (standard), 5s, 10s, 15s, 60s, & “Less Time-out”. The “Less Time-out” option
actually ceases water flow (turns off) after 20 minutes to limit chance of water damage in the event a sink drain becomes blocked .
Sensing Mode (DEFAULT):
During this mode the valve will shut off after hands are removed. If hands are not removed the time out delay will turn off the faucet (ex:
standard configuration is 30 seconds)) (See Sensing & Metering Mode flow chart above page)
Metering Mode:
When hands are detected by the sensor, water will run for ‘ X’ seconds (standard configuration is 30 seconds) before turning off. (See
Sensing & Metering Mode flow chart on following page)
Sensor Sensitivity:
(Default setting: Low):
There are 4 sensitivity options, which can be selected to achieve the optimal detection performance related to the sink material, shape,
& finish. The faucet sensor sensitivity is configured during pack-out but the mode can be changed upon installation to optimize the
performance within the sink. Sensor sensitivity and sensor detection Modes A & B may be tried for various lighting conditions, sink
materials and shape.
Switch 7 controls the sensitivity
-On (default) is normal sensitivity for most sinks providing max range.
-Off set the sensor to a lower sensitivity level for sinks that cause false activation. The detection range maybe less for all hands.
Switch 8 controls sensor mode
-On (default) enables the mode that filters the effects of flowing in the bottom of problematic sinks. Detection maybe less for some
hands.
-Off disable the filter mode, so detection is expanded deeper into the sink for max detection range for all hands. Some sinks may
only be able to operate in this mode.
NOTE: After a configuration switch change has been made. Disconnect sensor cable from electronics box, wait 30 seconds, then
reconnect sensor cable and wait 30 additional seconds to allow the sensor to tune-in the sink characteristics. Calibration includes
characterizing the sink with water running into the bowl. This could be 5 to 60 seconds depending on configuration.
All switches shown in
default mode.
Switch Position:
1
2
3
4
5
6
7
8
Purge (Hours)
Disable:
12:
24:
48:
Off
On
Off
On
Off
Off
On
On
Time 30:
(Seconds) 5:
10:
15:
60:
Less Time-out
Off
On
Off
On
Off
On
Off
Off
On
On
Off
Off
Off
Off
Off
Off
On
On
Mode Select
Sensing Mode:
Metering Mode:
Off
On
Sensor Sensitivity
Low:
Off
Normal:
On
Mode A:
Off
Mode B:
On
Adjustable modes and features selection