background image

FV801 Rev.  A  06/21/21 

Page 7

   

 

Gateway Instruction

Register in plumbSMART

You can request your Ethernet or LTE gateway by visiting 

Zurn.com/plumbsmart-gateway-request

or call Zurn Customer Care at 1-844-987-6737

Step 1. Request Gateway:

Step 2. Cabling, Powering and Connecting Your Device:

1. 

Connect one end of the RJ45 Ethernet cable (supplied) to the 

gateway’s Ethernet port and plug the cable’s other end into the 

nearest wall port of the building’s Ethernet network.

2. 

Connect the power supply to the power jack.

3. Wait for status LED to go from ON to double flash every second, 

the LoRa LED to turn ON solid, and the cell LED (if LTE enabled) 

to flash once every 3 seconds. Should take around 1-2 minutes 

depending on location. Your gateway is now ready to transmit 

data from your Zurn connected product.

4. Zurn  Gateways  have  been  set  to  DHCP  by  default.  Please 

consult local IT support for possible additional access 

requirements for your network.

Step 3. Determining general Location for the Zurn Gateway:

•  Select a location central to all devices to be connected to this 

gateway. Place the gateway as high as possible, such as near 

the top of a wall.

• 

Avoid  obstructions. Thick  walls  and  reflective  surfaces,  such 

as metal, weaken the signal between the gateway and other 

devices.

• 

The LoRa antenna is an omni-directional antenna, but for best 

results, mount the device so the LoRa antenna is in a vertical 

position near the top of a wall. We recommend conducting a site 

survey to test the signal strength in different locations before 

you mount the device.

Step 4. Mounting the Zurn Gateway:

The device ships with a mounting bracket. You will also need:

•  Four #6 screws with anchors 
•  Screwdriver 
• 

Drill

1. 

Determine where you want to mount the device.

2. 

Mark where you want the screws to go.

3. Drill holes for the screws and insert anchors.
4. Place the mounting bracket and secure it with screws.

5. 

Attach the device to the bracket and rotate to lock into place.

NOTE:  Instructions below are duplicated from registration card supplied with monitor

1.  Install Zurn Connected Product(s)

2. 

Install Zurn Gateway per the Gateway Instructions Manual

3.  Request plumbSMART Administrator Account at 844-987-6737

4.  Zurn creates your Enterprise Account for you! (You will be required to identify your building location, number of floors, and number 

of rooms.)

5. 

Log in to plumbsmart.zurn.com

6. 

Register each Connected Product in plumbSMART (Watch How-To Videos to Get Started. Located in the support section inside the 

portal.)

7.  Now, Relax.  You’re Connected.

Summary of Contents for AquaSense Camaya Z6953-XL-W2

Page 1: ... of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective g...

Page 2: ...ce to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving ante...

Page 3: ...nd finish Operating Water Pressure 10 125 psi Operational Water Temperature 33 F to 140 F 1 C to 60 C Aerator 0 5 GPM Vandal Resistant Standard Important Safety Information Installer is responsible for ensuring the product is installed and conforms to all plumbing codes and ordinances Do not convert or modify this Zurn product yourself All warranties will be voided Water supply lines must be sized...

Page 4: ... Gasket Aerator and Key Electronics Box with Solenoid Filter Spout Assembly Required Tools Batteries Batteries AquaSense Package Contents Adjustable Wrench Optional Smooth Jawed Wrench Phillips Head Screwdriver 3 32 M3 Allen Wrenches Filter Shank Mounting Kit Base Gasket Electronics Box with Solenoid Valve Hydrogenerator Y Cable Y Cable ...

Page 5: ...and or internal control and mixing valve 1 Carefully screw aerator into spout using included tool Take care to not pinch blue o ring 3 Ensure that slot in plastic washer is facing forward Sensor cable should pass through the front of the plastic mounting washer Spout Installation Instructions Z6953 XL W2 Z6956 XL W2 Cover Plate Installation Instructions 1 For faucets with CP4 or CP8 suffix Pass se...

Page 6: ...lied batteries Close lid and tighten lid screw 4 Connect sensor inline connector to electronics module and hydrogenerator Do not connect cable to the monitor at this step Use AA Lithium Batteries or AAAlkaline batteries but do not mix Lithium with Alkaline Monitor Electronic Module Installation Instructions 3 Connect the hydrogenerator A downstream of electronics module B and filter C to bottom of...

Page 7: ...mildly warm soapy water and then wipe the device dry with a clean soft towel or cloth Upon cleaning other areas of the restroom be sure the sensor lenses are protected from other cleaning chemicals solvents to prevent potential damages to the sensor and or electronics Care and Cleaning Instructions 6 Tighten electronics module assembly to shank and connect water line s 5 Open battery module using ...

Page 8: ...ctions Thick walls and reflective surfaces such as metal weaken the signal between the gateway and other devices The LoRa antenna is an omni directional antenna but for best results mount the device so the LoRa antenna is in a vertical position near the top of a wall We recommend conducting a site survey to test the signal strength in different locations before you mount the device Step 4 Mounting...

Page 9: ...sitivity is configured during pack out but the mode can be changed upon installation to optimize the performance within the sink Sensor sensitivity and sensor detection Modes A B may be tried for various lighting conditions sink materials and shape Switch 7 controls the sensitivity On default is normal sensitivity for most sinks providing max range Off set the sensor to a lower sensitivity level f...

Page 10: ... enough time to calibrate prior to a user or target trying to initiate activa tion Disconnect the sensor and electronic box cables and wait for 30 seconds Reconnect the cables but allow for another 30 seconds before placing hands or a target within the sensor range You should hear a click of the solenoid once calibration is complete Check if protective film was removed from lens Water does not sto...

Page 11: ...R sensor and Faucet actuator electronics Restore proper electrical connection as needed Step 2 Test activate the faucet If problem persists see Faucet Troubleshooting section in this guide for other steps Status Good posted in plumbSMART and faucet actuates but usage event data not appearing in plumbSMART Charts Step 1 Verify gateway is powered and LoRa Status LED is ON If not apply power per Zurn...

Page 12: ...acility IT administrator to modify port rules to allow Zurn gateway to access the internet via local router If gateway model is ETH LTE visually verify SIM card is installed in designated slot on the side of gateway If unit has a SIM card then disconnect ethernet cable and power cycle the gateway and wait for unit to initialize and connect LORA LED should turn ON solid after initialization Step 4 ...

Page 13: ...ect fixture model Verify product image and model number from plumbSMART product page Details tab against model number cited on product literature and packaging If incorrect contact Zurn Custom Service at 1 855 ONE ZURN 1 855 663 9876 for assistance High Daily Faucet Activate Rate posted in plumbSMART Step 1 Verify faucet is not falsely triggering See Faucet Troubleshooting section for appropriate ...

Page 14: ...To service solenoid use Phillips head screw driver to remove the screws on both sides of the electronics box With screws removed the electronics box can slide off and allow access to the solenoid for service Accessing the Solenoid ...

Page 15: ...pplied Adapter 3 8 Copper Tube By Others For use with MV Option Mixing Valve Filter and Mixing Valve Installation Control Box Attach adapter or Braided Hose SSH here with MV and TMV 1 options SSH suffix option P6900 12BC Filter Need to hold at pointed area by suitable wrench or by hand while applying torque to the supply hose nut Do not over torque the nut ...

Page 16: ...it Item 3 P6900 43 Hydrogenerator Assembly Item 4 P6900 HYD Electronics Box with Solenoid Item 5 P6950 XL B L Sensor Inline Connector Item 6 P6950 XL DC Description Product No Smart Connected Faucet Retrofit Kit Item 7 P6900 RK W2 8 Cast Cover Plate w Gasket Item 8 P6900 CP8 4 Cast Cover Plate w Gasket Item 9 P6900 CP4 Single Stainless Supply Hose XL Item 10 P6900 SH XL Stainless Supply Hoses XL I...

Reviews: