43/71
User Manual for hybrid inverter HYD 10-20KTL-3PH - Rev. 1.0 of 25/08/2020
Identification: MD-AL-GI-00
Identification: MD-AL-GI-00
Rev. 4.0 of 31.01.18 - Application: GID
4. Storage mode
4.Energy Storage Mode
OK
1.Self-use Mode
OK
2.Time-of-use Mode
3.Timing Mode
4.Passive Mode
OK
Self-consumption mode
The inverter automatically charges and discharges the battery.
If the PV generation (kW) = consumption (kW), with ∆P < 100W, the inverter does not charge or
discharge the battery
Figure 39a).
If the PV generation (kW) > consumption (kW), the surplus power is stored in the battery
Figure 39b).
Figure 39 - Inverter display in self-consumption mode (1)
If the PV generation (kW) < consumption (kW), the battery is discharged to provide the necessary
power, until it is completely discharged (
If the battery is fully charged (or at maximum charging power), the surplus power is transferred to the
grid (
a)
b)
a)
b)