Chapter 3
Error! Style not defined.
Confidential and Proprietary Information of ZTE CORPORATION
31
Checking Power Supply
Check whether the power supply of ZXMBW E9200 meets the
requirement as described in Table 12.
T
A B L E
1 2
Z X M B W
E 9 2 0 0
P
O W E R S U P P L Y
R
E Q U I R E M E N T
Type
Nominal value
Voltage range
AC
110 V /220V AC
85 V AC~265V AC, 50/60Hz
Checking Grounding Mode
The ZXMBW E9200 applies the joint grounding mode. The
grounding resistance must be less than 5
Ω
.
Other Checks
Make sure that accessories or parts (e.g. antenna pole,
grounding copper bus-bar) are in accordance with the
ZXMBW E9200 engineering design.
Make sure that interconnection devices such as AGW, and
power supply are available.
Tools and Instruments Preparation
Prepare installation tools and test instruments according to the
actual situation. Table 13 and Table 14 list the common tools
and instruments.
T
A B L E
1 3
T
O O L S
L
I S T
Type
Tool
Special-purpose
tools
Knife for cutting feeder ends
Wire stripper for coaxial cables
One crimping pliers for coaxial cables
Multi-functional crimping pliers
Concrete
drilling tools
Electric percussion drill
Auxiliary bits
Vacuum cleaner
Power socket (two-phase and three-phase socket)