PREMIER EX PLUS – OPERATION & INSTALLATION MANUAL
PAGE 12
DOCUMENT: GLT-MAN.115
ISSUE: 1 DATE: 22/8/05
AUTHOR: NRPJ
CHARGER FAULT
•
Check that mains is present.
•
Check mains fuse
•
Check Charger fuse
BATTERY FAULT
•
Check that 2 x 12V SLA batteries are connected in SERIES.
•
Check battery voltage
•
Check battery fuse.
MANUAL RELEASE FAULT
•
Check for breaks in the cable
•
Check that correct value EOL is fitted
HOLD ABORT FAULT
•
Check for breaks in the cable
•
Check that correct value EOL is fitted
AUTO/MANUAL FAULT
•
Check for breaks in the cable
•
Check that correct value EOL is fitted
GAS FIRED FAULT
Yellow LED only
•
Check for breaks in the cable
•
Check that correct value EOL is fitted
RED & Yellow LEDs
•
Check for Short Circuit on the line.
•
Check the Gas Fired output from the bottle (usually weigh scales)