Using the ARRM Function
ZOOM PFX-9003
37
5.
Use slider 3 to set the direction and range of the change at the
control target.
• UP
The parameter changes from the minimum value to the maximum value
according to the level change of the control waveform.
• dn
As for UP, the parameter changes from the minimum value to the maximum
value, but in opposite relation to the level change of the control waveform.
(When the control waveform is maximum, the parameter is minimum, and
vice versa.)
• Hi
The parameter changes from the patch setting level (or the MINVOL
parameter value) to the maximum value according to the level change of
the control waveform.
• Lo
The parameter changes from the minimum value to the patch setting level
(or the MINVOL parameter value) according to the level change of the
control waveform.
For example, if rising sawtooth is selected as control waveform, the parameter
will change as shown below, depending on the MODE parameter setting.
"UP"
"Hi"
"dn"
"Lo"
Maximum
value
Minimum
value
Maximum
value
Minimum
value
Time
Time
Time
Time
Maximum
value
Patch internal
setting value
Patch internal
setting value
Minimum
value