background image

Page: 5/17

26

23

24

25 

1. Control panel
2. Horizontal louvre
3. Vertical louvre
4. Air outlet frame
5. Vertical Louvre connecting lever
6. Caster
7. Horizontal louvre connecting lever
8. Main vertical louver
9. Front shell

10. Handle position (right side: remote control storage area)
11. Back shell
12. C shape bucke of the heat
exhaust hose snap
13. Power cord

14. Lower air duct bottom

15. Wire-winding post

16. Drain cap

17. Evaporator filter mesh

18. Evaporator filter frame

19. Radiating fine mesh

20. Condenser filter mesh

21. Condenser filter frame

22. Base plate

23. Remote control

24. Heat exhaust hose short connector

25. Heat exhaust hose

26. Window sealing board assembly

Installation Adjustment

1. Installation

Warning:  leave  this  mobile  air-conditioner  in  an  upright  position  for  at  least  2 

hours before first use. 

This air-conditioner may be moved indoor conveniently; leave the air-conditioner in an 

upright position while moving it. The air-conditioner shall be placed on a flat ground surface. 
Do not install or operate this air-conditioner in a bathroom or other wet environments. 

1.1. Assembly of the heat exhaust hose and heat exhaust hose short connector (as shown in 

Figure 1) 

Figure 1                                                              Figure 2 

    1). Take out the heat exhaust hose short connector and heat exhaust hose, and remove the 

plastic bag. 

2). Pull the few turns at the end of the heat exhaust hose apart, screw the round end of the 

heat exhaust hose short connector counterclockwise into the heat exhaust hose to form 
the heat exhaust hose assembly (as shown in Figure 2). 
Note:  1.  The  heat  exhaust  hose  and  heat  exhaust  hose  short  connector  shall  be 

screwed into place and the heat exhaust hose shall be screwed in at least 3 turns. 

Summary of Contents for YPO2-09C

Page 1: ...Page 1 17 YPO2 09C Portable Air Conditioner User s Manual...

Page 2: ...Water Drainage Methods 12 Maintenance 13 End of Season Storage 15 Handling of the Unit 14 Troubleshooting 16 Appendix 17 Thank you for selecting this super quality air conditioner Please keep this Use...

Page 3: ...ction of the drain pipe is in good condition without flexure When adjusting the horizontal vertical louver at the air outlet turn it slightly by hand to avoid damage of the louvre Keep the unit in an...

Page 4: ...OFF setting Features and Parts 1 Features Brand new appearance compact structure with a sense of streamline The appearance of the unit is beautiful and elegant the remote control can be placed on the...

Page 5: ...oner in an upright position for at least 2 hours before first use This air conditioner may be moved indoor conveniently leave the air conditioner in an upright position while moving it The air conditi...

Page 6: ...t of the back shell and the C shape buckle of the heat exhaust hose 1 3 Installation of the heat exhaust hose assembly and unit 1 Pull the end of the heat exhaust hose apart by several turns 2 Hold th...

Page 7: ...ust the distance of the window sealing board assembly pulled apart so that the two ends of the assembly come into contact with the window frame and fasten the parts of the assembly with copper screws...

Page 8: ...structions of the control panel 1 Select the operation interface depending on the models and functions The operation interfaces of the cooling only and cooling heating models are as follows 1 Cooling...

Page 9: ...mpressor shuts down When the ambient temperature rises to be 17 the compressor starts again The start stop of the compressor meets the requirement for 3 minute protection time The fan is forced to swi...

Page 10: ...ton to decrease the temperature and timing value 7 F button press this button to switch between the Celsius degree and Fahrenheit degree 8 Cool button press this button to set this unit to operate in...

Page 11: ...inutes continuously the unit enters fluorine free protection the compressor and water spraying motor turn off the fan operates in the low speed mode and E3 is displayed Remote Control 1 2 3 4 5 6 7 C...

Page 12: ...p tightly Note 1 Turn on the unit only after the water plug and drain cap are installed properly otherwise the condensate of the unit will flow onto the ground or carpet Drain cap Water plug Figure 12...

Page 13: ...ilter frame gently in the direction shown by the arrow as shown in Figure 12 2 Grip the gripping position of the evaporator filter mesh and condenser filter mesh and take out the filter mesh gently in...

Page 14: ...ame in the reverse order of removal Be sure to install the filter mesh first before the filter frame is installed 2 Install the filter frame gently so as not to damage it 3 Cleaning of the handle posi...

Page 15: ...g the power plug wrap the power cord around the wire winding post insert the plug into the universal jack at the back shell of the unit install the water plug and drain cap 4 Remove the heat exhaust h...

Page 16: ...dirty Clean or replace the filter mesh Air inlet or air outlet clogged Remove the obstruction Large noise Air conditioner not put on a flat surface Put the air conditioner in a flat and firm place may...

Page 17: ...gram of the air conditioner For specific technical parameters of the models refer to the nameplate on the product s Disposal do not store waste products with other non classified wastes Such wastes sh...