background image

Page: 12/17 

Water Drainage 

1. Manual drain: (as shown in Figure 12)

1). Once the unit shuts down upon full water, turn off the power of the unit and then unplug

the power plug. 

Note: move the unit carefully to avoid spillage of water in the water tray at the bottom 

of the unit. 

2). Put the vessel that holds water below the water outlet at the back of the unit. 
3). Screw off the drain cap, unplug the water plug and water will flow into the vessel that 

holds water automatically. 

Note: 1. Protect the drain cap and water plug properly. 

2. Tilt the unit slightly backward when draining.
3. If  the  vessel  that  holds  water  can  not  hold  all  water  in  the  unit,  before  the

vessel that holds water is full of water, block the water outlet with the water
plug as soon as possible to prevent the water from flowing onto the ground or
carpet.

4). Once the water is fully drained, insert the water plug and screw on the water cap tightly. 
      Note: 1. Turn on the unit only after the water plug and drain cap are installed properly; 

otherwise, the condensate of the unit will flow onto the ground or carpet. 

Drain

 cap

Water plug 

Figure 12

Water outlet 

2.

Continuous drain:

1). Screw off the water cap in the direction shown by the arrow and unplug the water plug;

(Figure 13) 
    2). Insert the OD 13mm PVC drain hose 8mm-10mm into the water outlet; (Figure 14) 
    3). Connect the drain hose to the WC or outdoor. 

Note:    1. The drain hose must be installed when there is not water in the baseplate; 

2. When operating in the cooling mode, to ensure the water for radiation of the

condenser  of  the  unit  and  enhance  the  cooling  effects  of  the  unit,  it  is
recommended that continuous drain not be set as far as possible when this
unit is in use;

3. When operating in the heating mode, adopt continuous drain; otherwise, the

unit may shut down due to full water;

4. Put the drain hose in an inaccessible place at a height not above the water

outlet and keep the drain hose free from flexure;

5. When  continuous  drain  is  adopted,  keep  the  drain  cap  and  water  plug

properly.

Summary of Contents for YPO2-09C

Page 1: ...Page 1 17 YPO2 09C Portable Air Conditioner User s Manual...

Page 2: ...Water Drainage Methods 12 Maintenance 13 End of Season Storage 15 Handling of the Unit 14 Troubleshooting 16 Appendix 17 Thank you for selecting this super quality air conditioner Please keep this Use...

Page 3: ...ction of the drain pipe is in good condition without flexure When adjusting the horizontal vertical louver at the air outlet turn it slightly by hand to avoid damage of the louvre Keep the unit in an...

Page 4: ...OFF setting Features and Parts 1 Features Brand new appearance compact structure with a sense of streamline The appearance of the unit is beautiful and elegant the remote control can be placed on the...

Page 5: ...oner in an upright position for at least 2 hours before first use This air conditioner may be moved indoor conveniently leave the air conditioner in an upright position while moving it The air conditi...

Page 6: ...t of the back shell and the C shape buckle of the heat exhaust hose 1 3 Installation of the heat exhaust hose assembly and unit 1 Pull the end of the heat exhaust hose apart by several turns 2 Hold th...

Page 7: ...ust the distance of the window sealing board assembly pulled apart so that the two ends of the assembly come into contact with the window frame and fasten the parts of the assembly with copper screws...

Page 8: ...structions of the control panel 1 Select the operation interface depending on the models and functions The operation interfaces of the cooling only and cooling heating models are as follows 1 Cooling...

Page 9: ...mpressor shuts down When the ambient temperature rises to be 17 the compressor starts again The start stop of the compressor meets the requirement for 3 minute protection time The fan is forced to swi...

Page 10: ...ton to decrease the temperature and timing value 7 F button press this button to switch between the Celsius degree and Fahrenheit degree 8 Cool button press this button to set this unit to operate in...

Page 11: ...inutes continuously the unit enters fluorine free protection the compressor and water spraying motor turn off the fan operates in the low speed mode and E3 is displayed Remote Control 1 2 3 4 5 6 7 C...

Page 12: ...p tightly Note 1 Turn on the unit only after the water plug and drain cap are installed properly otherwise the condensate of the unit will flow onto the ground or carpet Drain cap Water plug Figure 12...

Page 13: ...ilter frame gently in the direction shown by the arrow as shown in Figure 12 2 Grip the gripping position of the evaporator filter mesh and condenser filter mesh and take out the filter mesh gently in...

Page 14: ...ame in the reverse order of removal Be sure to install the filter mesh first before the filter frame is installed 2 Install the filter frame gently so as not to damage it 3 Cleaning of the handle posi...

Page 15: ...g the power plug wrap the power cord around the wire winding post insert the plug into the universal jack at the back shell of the unit install the water plug and drain cap 4 Remove the heat exhaust h...

Page 16: ...dirty Clean or replace the filter mesh Air inlet or air outlet clogged Remove the obstruction Large noise Air conditioner not put on a flat surface Put the air conditioner in a flat and firm place may...

Page 17: ...gram of the air conditioner For specific technical parameters of the models refer to the nameplate on the product s Disposal do not store waste products with other non classified wastes Such wastes sh...

Reviews: