Service Parameter Setting
20X Bar-tacking and Button Sewing Machine(LCD N)
71
K112
Main shaft stop correction
-
10
~
10
0
K120
Stitch number for alarm to add lubricating
oil
3000
~
12000
5000
Unit: ten
thousand
stitches
K121
Counter Lock
0: Clear and Plus/Minus;
1: Clear Only;
2: Plus/Minus Only;
3: Neither Clear nor Plus/Minus
0
K122
OC length adjustment
-
128
~
128
0
K123
OD length adjustment
-
128
~
128
0
K124
BD length adjustment
-
512
~
512
0
K125
OC length
1780
~
2380
2080
K126
OD length
1450
~
2050
1750
K127
BD length
390
~
590
490
K128
Stepping Drive Type
0: DSP1 Close DSP2 Close
1: DSP1 Open DSP2 Open
2: DSP1 Close DSP2 Open
3: DSP1 Open DSP2 Open
0
Effective after
restart
K135
Thread-separating delay
-
10
~
30
0
K137
Thread clamp release angle at sewing start
-
150
~
150
0
K138
Thread clamp holding time after trimming
at sewing start
-
2
~
1
0
-2 means thread
holding action
prohibited after
thread-trimming
at sewing start
K140
Thread Tension Control Method
0: electronic
1: mechanical
0
K141
Suction force adjustment of branch thread
tension solenoid
-
20
~
20
0
K142
Holding force adjustment of branch thread
tension solenoid
-
40
~
40
0
K150
Invalidity of head tilt safety switch
0: Normal
1: The safety status of tilt head is
invalid.
0
K160
Prohibit stepping the pedal backward for
emergency stop
0
~
1
0
0:Allowed
1:Prohibited
K164
The height of the middle pressure foot
14~18
16
Only if the K02
parameter is set
to 3
K165
The height of the middle pressure foot
follows
0~10
3
Only if the K02
parameter is set
to 3