230 VAC 1ø

FROM CONTACTOR

RELAY

START

1

2

5

BLACK

CAPACITORS

START

RUN CAPACITOR

WHITE

BLACK

RED

WHITE

MAIN

PUMP

START

4

5

1

L1

L2

C-1

C-2

C-3

GREEN

SINGLE PHASE INSTALLATION

All single phase models require start capacitor, run capacitor and relay in the circuit to start and operate properly. These components can be purchased separately 

or prewired in Zoeller control panel. For components purchased separately used the diagram for installation and hookup.
Single phase models are nonautomatic. To operate automatically a control panel  must be added to the power circuit. Follow the instructions provided with the panel.

ZEPA0041

ZEPA0040

WIRING DIAGRAM

1

2

5

L2

T2

T1

L1

RELAY

START

MOTOR

BLACK

START CAPACITORS

WHITE

230 VAC 1Ø

RUN CAPACITOR

4

WHITE

RED

BLACK

PUMP

START

5

MAIN

1

C-1

C-2

C-3

GREEN

(460-552MF, 125 VOLTS)

(30MF, 440 VOLTS)

COMPONENT LAYOUT

WIRING DIAGRAM 

ZEPA0043

COMPONENT LAYOUT

ZEPA0042

 5 BHP MODEL 6220

7½ BHP MODEL 6221

C-4

MAIN

START

PUMP

RED

BLACK

C-3

RUN CAPACITORS

C-1

C-2

START

CAPACITORS

BLACK

5

2

1

5 1

4

START

RELAY

FROM CONTACTOR

230 VAC 1ø

WHITE

L1

L2

WHITE

GREEN

WHITE

START CAPACITORS

RUN CAPACITORS

RELAY

START

C-1

C-2

C-4

C-3

4

230 VAC 1Ø

BLACK

RED

WHITE

PUMP

MAIN

START

BLACK

L1

T1

T2

L2

1

5

2

5

1

GREEN

(20MF, 370 VOLTS)

(590-708MF, 110-125 VOLTS)

NOTES:

1. “

” DENOTES A TERMINAL ON    

 

MOTOR START RELAY ASSEMBLY.

2.  “Ο” DENOTES MOTOR TERMINAL. 

3.  MOTOR EQUIPPED WITH MOISTURE  

 

PROBES AND THERMAL SENSORS.  

 

REFER TO 3 PHASE WIRING DIAGRAM  

 BELOW.

NOTES:

1. “

” DENOTES A TERMINAL ON    

 

MOTOR  START RELAY ASSEMBLY.

2.  “Ο” DENOTES MOTOR TERMINAL. 

3.  MOTOR  EQUIPPED WITH MOISTURE  

 

PROBES AND THERMAL SENSORS.  

 

REFER TO 3 PHASE WIRING DIAGRAM  

 BELOW.

THREE PHASE INSTALLATION

NOTE 1:

 

Sensor cable includes 5 leads; 2 leads for thermal sensor , 2 leads for moisture sensor, and a green ground lead. Sensor wire colors are as shown.

Refer to Sensor and Control Panel sections on page 5.

T3

T2

T1

L3

L2

L1

POWER CABLE

3 PHASE MOTOR

3Ø VAC

SENSOR CABLE

BLUE

GRAY

BROWN

BLACK

GREEN/YELLOW

SEAL FAILURE MOISTURE SENSOR

LEADS MUST BE CONNECTED TO

INDUCTION CIRCUIT IN THE CONTROL

PANEL

RECOMMENDED THERMAL SENSOR

CONNECTED IN SERIES WITH 

STARTER COIL

SEAL FAILURE PROBES

330K OHMS RESISTANCE

THERMAL 

SENSOR

(N/C)

TYPICAL 3-PHASE  WIRING DIAGRAM, CE MODEL

ZEPA0641

(N/C)

SENSOR

330K OHMS RESISTANCE

SEAL FAILURE PROBES

PANEL.

INDUCTION CIRCUIT IN THE CONTROL

LEADS MUST BE CONNECTED TO 

SEAL FAILURE MOISTURE SENSOR

THERMAL

THE THERMAL SENSOR LEADS

ARE TO BE CONNECTED IN

SERIES WITH STARTER COIL

NOTE 1

SENSOR  CABLE WITH THERMAL AND

MOISTURE PROTECTION IS STANDARD

ON ALL EXPLOSION PROOF MOTORS

(SEE NOTE 1)

SENSOR CABLE

P2

WHITE

P1

BLACK

W1

RED

W2

ORANGE

TYPICAL 3-PHASE  WIRING DIAGRAM, STANDARD UNIT

ZEPA0038

Summary of Contents for Z62 HD Series

Page 1: ...2 774 3624 visit our web site zoellerengineered com Model Number _______________ Date Code ____________________ Serial Number Pump 1_____________ Pump 2_____________ Simplex Panel P N ______________________________ Duplex Rail System P N ________________________ Job Name _____________________________________________ Distributor ____________________________________________ Sales Order Number ______...

Page 2: ...er capacity Aseparate branch circuit is recommended sized according to the governing electrical codes for the current shown on the pump name plate 4 Testing for ground As a safety measure each electrical outlet should be checked for ground using an Underwriters Laboratory Listed circuit analyzer which will indicate if the power neutral and ground wires are correctly connected to your outlet If the...

Page 3: ...0 3 60 22 9 10 5 95 F 0 72 5 05 G6221 1 2 1750 460 3 60 11 4 5 5 2 47 5 F 2 8 5 05 BA6221 1 2 1750 575 3 60 9 3 5 3 9 37 8 F 4 5 5 02 AK6222 1 2 1400 380 3 50 11 5 1 6 4 41 E 2 8 4 78 J6222 1 2 1750 200 3 60 32 10 8 12 4 109 C 0 61 3 78 F6222 1 2 1750 230 3 60 28 9 11 7 95 C 0 72 3 78 G6222 1 2 1750 460 3 60 14 4 5 5 7 47 5 C 2 8 3 78 BA6222 1 2 1750 575 3 60 11 3 5 4 3 37 8 C 4 5 3 76 AK6223 1 2 ...

Page 4: ...hebasincoverandcleanedperiodically Water stream will be visible from this hole during pump run periods Also a vent hole is drilled in the pump housing Be sure this hole is cleared during any servicing 7 Ventgasesandodorstotheatmospherethroughventpipepergoverning codes 8 Secure power cord to avoid entanglement with variable level float switch mechanism 9 Do not reduce pump discharge pipe below 10 c...

Page 5: ...tor housing contains water or other contamination both seals should be replaced during maintenance Always replace with new factory recommended oil and service parts All warranty repairs must be made by an authorized Zoeller representative 5 On existing applications where the control panel only has one moisture sensor hookup per pump one moisture sensor lead from the pump should be hooked to the mo...

Page 6: ...CK L1 T1 T2 L2 1 5 2 5 1 GREEN 20MF 370 VOLTS 590 708MF 110 125 VOLTS NOTES 1 DENOTES A TERMINAL ON MOTOR START RELAY ASSEMBLY 2 Ο DENOTES MOTOR TERMINAL 3 MOTOR EQUIPPED WITH MOISTURE PROBES AND THERMAL SENSORS REFERTO3PHASEWIRINGDIAGRAM BELOW NOTES 1 DENOTES A TERMINAL ON MOTOR START RELAY ASSEMBLY 2 Ο DENOTES MOTOR TERMINAL 3 MOTOR EQUIPPED WITH MOISTURE PROBES AND THERMAL SENSORS REFER TO 3 PH...

Page 7: ...months the following is recommended Pumps If pit is to remain dry the pump can remain in the pit With the pump in the pit it should be operated for five minutes once every three months If the pit is to remain wet the pump should be removed and stored as noted above Panels The panel should have all openings sealed to prevent moisture and dust from enteringtheenclosure Priortorestartingsystem thepan...

Page 8: ...fective Pit too small D Pump will not shut off Debris clogging cutter mechanism Debris under float switch Float travel obstructed Damaged float switch Magnetic starter contacts shorted Air lock check vent hole E Pump operates but delivers little or no water Check for plugged cutter pump housing pipe or sticking check valve Vent hole clogged or not drilled Discharge head exceeds pump s capacity Low...