SEAL FAILURE

BLACK & WHITE 

LEAD  

GROUND

POWER 

CORD 

LEAD

SENSOR CORD 

GREEN GROUND 

BLACK

GREEN  

RED 

WHITE

SENSOR

LEADS

TEMPERATURE

RED & ORANGE

SENSOR

LEADS

“62 HD SERIES” FOUR CONDUCTOR AWG. POWER CORD SIZE

60 Hz

50 Hz

MODEL

230/1PH

200/3PH

230/3PH

460/3PH

575/3PH

380/3PH STD.

380/3PH CE

6220

8 AWG.

12 AWG.

12 AWG.

12 AWG.

12 AWG.

6221

8 AWG.

8 AWG.

8 AWG.

12 AWG.

12 AWG.

6222

N/A

8 AWG.

8 AWG.

12 AWG.

12 AWG.

6223

N/A

4 AWG.

4 AWG.

8 AWG.

12 AWG.

6224

N/A

4 AWG.

4 AWG.

8 AWG.

8 AWG.

APPROXIMATE CORD DIAMETER PER GAUGE

12 / 4 AWG apprx. = 0.64”

8 / 4 AWG apprx. = 0.93”

H07RN apprx. = 0.58”

 Installation and checking of pump, electrical circuits and hardware should be performed by a qualified licensed electrician.
 Risk of electrical shock.  

Do not remove power supply cord and strain relief or connect conduit directly to the pump.

Power cords, sensor cords and float cords must be sealed to prevent gases from the basin entering the control panel.

INSTRUCTIONS FOR CHECKING ROTATION OF THREE PHASE UNITS

It is very important that these units be connected for proper rotation.  Since no rotating parts are visible without removing the pump from the pit, the rotation on 3 

phase units should be checked before installation into the pit as follows:

After the proper electrical connections are made, momentarily energize the pump observing the direction of kick back due to starting torque. The rotation is correct if the kick back 

is in the opposite direction of the rotation arrow. If the rotation is not correct, disconnect power and switch any two power leads. Turn power back on and retest for proper rotation.

THERMAL SENSOR PROTECTION (OPTIONAL FEATURE)

Two thermal sensors and leads are wired in series with each other and located adjacent to the motor windings. When the temperature exceeds the maximum recommended limit, 

the pump will deactivate when the lead wires are connected to the magnetic starter circuit of a control panel with the thermal cutout feature. Continual deactivation of this circuit 

requires attention from maintenance personnel.

MOISTURE SENSORS (OPTIONAL FEATURE)

(1)  Pumps with moisture sensors have a separate sensor cord in addition to the power cord.

(2)  Sensor cord conductors are connected to sensors probes in the lower seal cavity. The conductor wires are terminated in the control panel for activating an indicator light 

when moisture is present in the lower seal cavity.

(3)  When the moisture indicator light is activated, the lower seal has allowed leakage of water into the lower oil-filled seal cavity. The pump should be serviced within 30 days to 

avoid damage to the motor and bearings.

(4)   Oil in the motor housing and lower seal cavity must be checked when pump is serviced. If oil from the motor housing contains water or other contamination, both seals should be 

replaced during maintenance. Always replace with new factory recommended oil and service parts. All warranty repairs must be made by an authorized Zoeller representative.

(5)   On existing applications where the control panel only has one moisture sensor hookup per pump, one moisture sensor lead from the pump should be hooked to the moisture 

sensor lead in the panel, the other moisture sensor lead from the pump should be hooked to ground to complete the circuit.

(6)  Moisture sensor circuit can be checked for continuity (complete circuit) with a (Volt-OHM-Meter).  Set the VOM to read resistance and connect the VOM leads to the sensor 

cord black and white wires.  The VOM should read approximately 330k Ohms.  Resistance readings significantly lower indicate a seal leak with water in the seal chamber.  

If VOM reading is open then a problem exists with moisture sensor circuit.

 

Check resistance between the green ground conductor of the pump power cord and the sensor cord black and white wires.  This resistance reading should indicate an open 

circuit.  If VOM reading returns a reading other than open, then a problem exists with the sensor circuit wiring or cordage.  If resistance

 

readings show a problem with either test, then pump should be repaired by an authorized Zoeller representative. 

PUMPS WITHOUT MOISTURE SENSORS

(1)  Double seal pumps offer extra protection from damage caused by seal failure. Pumps are installed without sensor probes.

(2)  Pumps without sensor probes should be serviced on a periodic preventative maintenance schedule.

(3)  Oil in the motor housing and lower seal cavity must be checked when pump is serviced. If oil from the motor housing contains water or other contaminations, both seals should 

be replaced during maintenance. Always replace with new factory recommended oil and service parts. All warranty repairs must be made by an authorized Zoeller representative.

CONTROL PANELS

These pumps are nonautomatic. They require a control panel. A motor starter circuit, control circuit, and alarm circuit within the panel are standard features. Outdoor enclosures 

and alternating relays are often required. Variable level float switches are the most common level sensing device. The following should be noted:

(1)  A pump incorporating the seal failure sensor and thermal sensor protection require that interfacing terminals and functions be incorporated into the panel.  

(2)  All pumps require overload protection in panel. Use with approved motor control that matches motor input in full load amperes with overload element(s) selected or adjusted 

in accordance with control instructions.

PUMP WIRING INSTRUCTIONS

POWER AND SENSOR CORD, LEAD IDENTIFICATION, NON CE MODEL

POWER AND SENSOR CORD, LEAD IDENTIFICATION, CE MODEL

CAUTION

ZEPA0640

NOTE: STANDARD SENSOR CORD 18/5 AWG. APPROXIMATELY 11 MM (0.43”) DIAMETER.  CE VERSION SENSOR CORD H07RN-F5G1 APPROXIMATELY 11mm (0.43”) DIAMETER

Summary of Contents for Z62 HD Series

Page 1: ...2 774 3624 visit our web site zoellerengineered com Model Number _______________ Date Code ____________________ Serial Number Pump 1_____________ Pump 2_____________ Simplex Panel P N ______________________________ Duplex Rail System P N ________________________ Job Name _____________________________________________ Distributor ____________________________________________ Sales Order Number ______...

Page 2: ...er capacity Aseparate branch circuit is recommended sized according to the governing electrical codes for the current shown on the pump name plate 4 Testing for ground As a safety measure each electrical outlet should be checked for ground using an Underwriters Laboratory Listed circuit analyzer which will indicate if the power neutral and ground wires are correctly connected to your outlet If the...

Page 3: ...0 3 60 22 9 10 5 95 F 0 72 5 05 G6221 1 2 1750 460 3 60 11 4 5 5 2 47 5 F 2 8 5 05 BA6221 1 2 1750 575 3 60 9 3 5 3 9 37 8 F 4 5 5 02 AK6222 1 2 1400 380 3 50 11 5 1 6 4 41 E 2 8 4 78 J6222 1 2 1750 200 3 60 32 10 8 12 4 109 C 0 61 3 78 F6222 1 2 1750 230 3 60 28 9 11 7 95 C 0 72 3 78 G6222 1 2 1750 460 3 60 14 4 5 5 7 47 5 C 2 8 3 78 BA6222 1 2 1750 575 3 60 11 3 5 4 3 37 8 C 4 5 3 76 AK6223 1 2 ...

Page 4: ...hebasincoverandcleanedperiodically Water stream will be visible from this hole during pump run periods Also a vent hole is drilled in the pump housing Be sure this hole is cleared during any servicing 7 Ventgasesandodorstotheatmospherethroughventpipepergoverning codes 8 Secure power cord to avoid entanglement with variable level float switch mechanism 9 Do not reduce pump discharge pipe below 10 c...

Page 5: ...tor housing contains water or other contamination both seals should be replaced during maintenance Always replace with new factory recommended oil and service parts All warranty repairs must be made by an authorized Zoeller representative 5 On existing applications where the control panel only has one moisture sensor hookup per pump one moisture sensor lead from the pump should be hooked to the mo...

Page 6: ...CK L1 T1 T2 L2 1 5 2 5 1 GREEN 20MF 370 VOLTS 590 708MF 110 125 VOLTS NOTES 1 DENOTES A TERMINAL ON MOTOR START RELAY ASSEMBLY 2 Ο DENOTES MOTOR TERMINAL 3 MOTOR EQUIPPED WITH MOISTURE PROBES AND THERMAL SENSORS REFERTO3PHASEWIRINGDIAGRAM BELOW NOTES 1 DENOTES A TERMINAL ON MOTOR START RELAY ASSEMBLY 2 Ο DENOTES MOTOR TERMINAL 3 MOTOR EQUIPPED WITH MOISTURE PROBES AND THERMAL SENSORS REFER TO 3 PH...

Page 7: ...months the following is recommended Pumps If pit is to remain dry the pump can remain in the pit With the pump in the pit it should be operated for five minutes once every three months If the pit is to remain wet the pump should be removed and stored as noted above Panels The panel should have all openings sealed to prevent moisture and dust from enteringtheenclosure Priortorestartingsystem thepan...

Page 8: ...fective Pit too small D Pump will not shut off Debris clogging cutter mechanism Debris under float switch Float travel obstructed Damaged float switch Magnetic starter contacts shorted Air lock check vent hole E Pump operates but delivers little or no water Check for plugged cutter pump housing pipe or sticking check valve Vent hole clogged or not drilled Discharge head exceeds pump s capacity Low...