ELECTRICAL DATA

Model

Service 

Factor

RPM

Volts

Ph

Hz

Amps

KVA 

Code

Winding 

Resistance

Line-to-Line

Code No.

Full 

Load

In Air

Shut Off

Locked 

Rotor

AK6220

1.2

1400

380

3

50

5.3

2.1

2.7

23

F

5.7

5.17

E6220

1.2

1750

230

1

60

27.5

12.1

13.7

91

D

0.55 / 2.1

4.19

J6220

1.2

1750

200

3

60

17.5

6.5

8.6

61.9

D

1

4.29

F6220

1.2

1750

230

3

60

15.2

5.4

6.4

53.8

D

1.5

4.29

G6220

1.2

1750

460

3

60

7.6

2.7

3.2

26.9

D

5.7

4.29

BA6220

1.2

1750

575

3

60

6.1

2.3

2.9

21.8

D

9

4.34

AK6221

1.2

1400

380

3

50

9.5

5.1

6

41

G

2.8

5.61

E6221

1.2

1750

230

1

60

36.7

9.3

13.5

137

D

0.5 / 2.1

4.20

J6221

1.2

1750

200

3

60

25

10.8

11.8

109

F

0.61

5.03

F6221

1.2

1750

230

3

60

22

9

10.5

95

F

0.72

5.05

G6221

1.2

1750

460

3

60

11

4.5

5.2

47.5

F

2.8

5.05

BA6221

1.2

1750

575

3

60

9

3.5

3.9

37.8

F

4.5

5.02

AK6222

1.2

1400

380

3

50

11

5.1

6.4

41

E

2.8

4.78

J6222

1.2

1750

200

3

60

32

10.8

12.4

109

C

0.61

3.78

F6222

1.2

1750

230

3

60

28

9

11.7

95

C

0.72

3.78

G6222

1.2

1750

460

3

60

14

4.5

5.7

47.5

C

2.8

3.78

BA6222

1.2

1750

575

3

60

11

3.5

4.3

37.8

C

4.5

3.76

AK6223

1.2

1400

380

3

50

14.7

6.2

7

75

G

1.55

5.90

J6223

1.2

1750

200

3

60

48.3

13.3

18.3

197

E

0.32

4.55

F6223

1.2

1750

230

3

60

41.7

13.8

15.4

172

E

0.39

4.57

G6223

1.2

1750

460

3

60

20.9

6.9

7.7

86

E

1.55

4.57

BA6223

1.2

1750

575

3

60

16.4

4.4

6.3

70

E

2.33

4.65

AK6224

1

1400

380

3

50

18

6.2

7.7

75

E

1.55

4.72

J6224

1

1750

200

3

60

59.4

13.5

21.2

197

B

0.32

3.41

F6224

1

1750

230

3

60

54

13.8

17.6

172

B

0.39

3.43

G6224

1

1750

460

3

60

27

6.9

8.8

86

B

1.55

3.43

BA6224

1

1750

575

3

60

22

4.6

7.3

70

B

2.33

3.49

Summary of Contents for Z62 HD Series

Page 1: ...2 774 3624 visit our web site zoellerengineered com Model Number _______________ Date Code ____________________ Serial Number Pump 1_____________ Pump 2_____________ Simplex Panel P N ______________________________ Duplex Rail System P N ________________________ Job Name _____________________________________________ Distributor ____________________________________________ Sales Order Number ______...

Page 2: ...er capacity Aseparate branch circuit is recommended sized according to the governing electrical codes for the current shown on the pump name plate 4 Testing for ground As a safety measure each electrical outlet should be checked for ground using an Underwriters Laboratory Listed circuit analyzer which will indicate if the power neutral and ground wires are correctly connected to your outlet If the...

Page 3: ...0 3 60 22 9 10 5 95 F 0 72 5 05 G6221 1 2 1750 460 3 60 11 4 5 5 2 47 5 F 2 8 5 05 BA6221 1 2 1750 575 3 60 9 3 5 3 9 37 8 F 4 5 5 02 AK6222 1 2 1400 380 3 50 11 5 1 6 4 41 E 2 8 4 78 J6222 1 2 1750 200 3 60 32 10 8 12 4 109 C 0 61 3 78 F6222 1 2 1750 230 3 60 28 9 11 7 95 C 0 72 3 78 G6222 1 2 1750 460 3 60 14 4 5 5 7 47 5 C 2 8 3 78 BA6222 1 2 1750 575 3 60 11 3 5 4 3 37 8 C 4 5 3 76 AK6223 1 2 ...

Page 4: ...hebasincoverandcleanedperiodically Water stream will be visible from this hole during pump run periods Also a vent hole is drilled in the pump housing Be sure this hole is cleared during any servicing 7 Ventgasesandodorstotheatmospherethroughventpipepergoverning codes 8 Secure power cord to avoid entanglement with variable level float switch mechanism 9 Do not reduce pump discharge pipe below 10 c...

Page 5: ...tor housing contains water or other contamination both seals should be replaced during maintenance Always replace with new factory recommended oil and service parts All warranty repairs must be made by an authorized Zoeller representative 5 On existing applications where the control panel only has one moisture sensor hookup per pump one moisture sensor lead from the pump should be hooked to the mo...

Page 6: ...CK L1 T1 T2 L2 1 5 2 5 1 GREEN 20MF 370 VOLTS 590 708MF 110 125 VOLTS NOTES 1 DENOTES A TERMINAL ON MOTOR START RELAY ASSEMBLY 2 Ο DENOTES MOTOR TERMINAL 3 MOTOR EQUIPPED WITH MOISTURE PROBES AND THERMAL SENSORS REFERTO3PHASEWIRINGDIAGRAM BELOW NOTES 1 DENOTES A TERMINAL ON MOTOR START RELAY ASSEMBLY 2 Ο DENOTES MOTOR TERMINAL 3 MOTOR EQUIPPED WITH MOISTURE PROBES AND THERMAL SENSORS REFER TO 3 PH...

Page 7: ...months the following is recommended Pumps If pit is to remain dry the pump can remain in the pit With the pump in the pit it should be operated for five minutes once every three months If the pit is to remain wet the pump should be removed and stored as noted above Panels The panel should have all openings sealed to prevent moisture and dust from enteringtheenclosure Priortorestartingsystem thepan...

Page 8: ...fective Pit too small D Pump will not shut off Debris clogging cutter mechanism Debris under float switch Float travel obstructed Damaged float switch Magnetic starter contacts shorted Air lock check vent hole E Pump operates but delivers little or no water Check for plugged cutter pump housing pipe or sticking check valve Vent hole clogged or not drilled Discharge head exceeds pump s capacity Low...

Reviews: