NOTICE TO INSTALLER: Instructions must remain with installation.

FM3148

1019

Supersedes

1218

© Copyright 2019 Zoeller

®

 Co. All rights reserved.

DATE INSTALLED:

MODEL NUMBER:

PREASSEMBLED SUMP PUMP SYSTEM WITH BATTERY BACKUP

MODEL 508 - 12 V DC BATTERY BACKUP SYSTEM

WITH 115 V AC POWERED SUMP PUMP

MODEL M53 OR M63 OR M98

INSTALLATION INSTRUCTIONS

SEE BELOW FOR

LIST OF WARNINGS

  1.  Make certain that the receptacle is within reach of the pump’s power supply 

cord.  Do not use primary pump circuit.  DO NOT USE AN EXTENSION CORD.  

Extension cords that are too long or too light do not deliver sufficient voltage 

to the pump motor, and they could present a safety hazard if the insulation 

were to become damaged or the connection end were to fall into a wet or 

damp area.

  2.  Make sure the pump electrical supply circuit is equipped with fuses or circuit 

breakers of proper capacity.  A separate branch circuit is recommended, 

sized according to the National Electrical Code for the current shown on the 

pump nameplate.

  3.  Testing for ground: as a safety measure, each electrical outlet should be 

checked for ground using an Underwriters Laboratory Listed circuit analyzer 

which will indicate if the power, neutral and ground wires are correctly 

connected to your outlet.  If they are not, call a qualified, licensed electrician.

  4.  For Added Safety: pumping and other equipment with a 3-prong grounded plug 

must be connected to a 3-prong grounded receptacle. For added safety the 

receptacle may be protected with a ground-fault circuit interrupter.  When 

a pump needs to be connected in a watertight junction box, the plug can be 

removed and spliced to the supply cable with proper grounding.  For added 

safety this circuit may be protected by a ground-fault circuit interrupter.  The 

complete installation must comply with the National Electrical Code and all 

applicable local codes and ordinances.

  5.  FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER 

SOURCE BEFORE HANDLING.  Single phase pumps are supplied with a 3-prong 

grounded plug to help protect you against the possibility of electrical shock.  

DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN.  The 

3-prong plug must be inserted into a mating 3-prong grounded receptacle.  

If the installation does not have such a receptacle, it must be changed to the 

proper type, wired and grounded in accordance with the National Electrical 

Code and all applicable local codes and ordinances.

  6.  The tank is to be vented in accordance with local plumbing code.  Pumps 

must be installed in accordance with the National Electrical Code and all 

applicable local codes and ordinances.  Pumps are not to be 

installed in locations classified as hazardous in accordance with 

National Electrical Code, ANSI/NFPA 70.

  7.  Risk of electrical shock. Do not remove power supply cord and strain relief 

or connect conduit directly to the pump.

 8.  Installation and servicing of electrical circuits and hardware should be 

performed by a qualified, licensed electrician.

  9.  Pump installation and servicing  should be performed by a qualified person.

 10.  Risk of electrical shock. These pumps have not been investigated for use in 

swimming pools and marine areas.

 11.  Prop65 Warning for California residents: Cancer and Reproductive Harm- 

www.P65Warnings.ca.gov.

 12.  It is the owner’s responsibility to check the battery and battery connection at 

least once a month. Batteries contain acid and caution must be taken when 

handling.

  1.  Check to be sure your power source is capable of handling the voltage 

requirements of the motor, as indicated on the pump name plate.

  2.  Vent hole. It is necessary that all submersible sump, effluent, 

and sewage 

pumps capable of handling various sizes of solid waste be of the bottom 

intake design to reduce clogging and seal failures.  Vent holes should 

be checked periodically for clogging.  The 50 Series pumps have a vent 

located in the pump housing opposite the float, adjacent to a housing lug. 

Water stream will be visible from this hole during pump run periods.

  3.  Pump should be checked frequently for debris and/or build up which may 

interfere 

with the float “on” or “off” position.  Repair and service should 

be performed by an Authorized Service and Warranty Center only.

  4.  Dewatering and effluent sump pumps are not designed for use in pits 

handling raw sewage.

  5.  Maximum operating temperature must not exceed 130 °F (54 °C).
  6.  Do not operate a pump in an application where the Total Dynamic Head is 

less than the minimum Total Dynamic Head listed on the Pump Performance 

Curves.

  7.  For indoor use only.
  8.  DC emergency pumps are designed for handling clear water.  Do not use 

in septic 

tanks to pump effluent or sewage pits to pump sewage.

  9.  Repair and service of your DC backup system should be performed by 

an Authorized Service and Warranty Center.

 10.  The installation of DC automatic backup pumps requires the use of a variable 

level 

float switch for operation.  It is the responsibility of the installing party, 

to ensure that the float switch will not hang up on the pump apparatus or 

pit peculiarities

 and is secured so the pump will turn “on” and “off”.  It is 

recommended that the pit be 18" (45.7 cm) in diameter or larger to accom-

modate both a primary and a DC backup pump.

NOTE:  Pumps with the “UL” mark and pumps with the “US” mark are tested to UL Standard 
UL778.  CSA Certified pumps are certified to CSA Standard C22.2 No. 108.

REFER TO WARRANTY ON PAGE 2.

CAUTION

SEE BELOW FOR

LIST OF CAUTIONS

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO

:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO

:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL

: (502) 778-2731 • 1 (800) 928-PUMP • 

FAX

: (502) 774-3624

Visit our website:

zoellerpumps.com

Patent No. D740329

NOTICE: VENT HOLE FOR 

CHECK VALVE SEE #2 IN 

CAUTION SECTION BELOW

Register your 

Zoeller Pump Company 

Product on our website:

http://reg.zoellerpumps.com/

 AQUANOT FIT 508/53, 508/63, 508/98

P/N155891

Summary of Contents for ProPak AQUANOT FIT 508/53

Page 1: ...servicing of electrical circuits and hardware should be performed by a qualified licensed electrician 9 Pump installation and servicing should be performed by a qualified person 10 Risk of electrical shock These pumps have not been investigated for use in swimming pools and marine areas 11 Prop65 Warning for California residents Cancer and Reproductive Harm www P65Warnings ca gov 12 It is the owne...

Page 2: ...s which vary from state to state 1 DC Pump won t run a Check for proper connections b Check all wire terminal points Clean if required c Check for low battery Service battery if required d Check 30 amp fuse on controller see fig 5 If fuse is blown replace with 30 amp automotive blade fuse 2 Pump runs but pumps very little or no water without AC power a Check for low battery Battery will recharge i...

Page 3: ...stallation conforms to each of them 11 DO consult manufacturer for clarifications or questions 12 DO inspectandtestsystemforproperoperationsatleasteverythree months Copyright 2019 Zoeller Co All rights reserved ELECTRICAL PRECAUTIONS Before servicing a pump always shut off the main power breaker and then unplug the pump making sure you are wearing insulated protective sole shoes and not standing i...

Page 4: ...ed Timeforrechargedependsupontheamountofpowerconsumed bythepumpingcycleduringtheACpowerinterruption Thepumpmaygo backtothereadyrunpositioninaveryshortperiodoftime Acompletely drained battery may require up to 24 hours for full recharge If battery does not charge properly the LED battery will flash red PERFORMANCE The DC pump performance at 12 7 Vdc BATTERY SELECTION Discharge Feet of Head 5 1 5 m ...

Page 5: ...al operating level and shut off b The yellow charging light should be on The charger is replacing the energy consumed during the test The green light will come on after the charger has replaced the energy consumed during the test 3 Add distilled water to battery when necessary per battery manufacturer s instructions CAUTION Battery acid is dangerous Take proper safety precautions Do not splash the...

Page 6: ... WATER REED SENSOR 1 1 2 SCH 40 PVC PIPE X 10 254 mm LG 1 1 2 SCH 40 PVC TEE NOTE CHECK VALVE SCREWS INTO PRIMARY PUMP DISCHARGE HAND TIGHTEN ONLY WEEP HOLE MUST BE VISIBLE OPERATIONAL FLOAT SWITCH DC PUMP CLAMP HIGH WATER REED SENSOR CHECK VALVE O RING PRIMARY PUMP CLAMP DC PUMP O RING TYPICAL INSTALLATION EXPLODED VIEW OF PUMP SYSTEM SK3182 SK3223 FIGURE 2 FIGURE 1 Copyright 2019 Zoeller Co All ...

Page 7: ...Pipe Pvc 1 5 X 10 Sch 40 1 019509 10 Fuse 30A Automotive Startard 1 016918 CHECKLIST EXPLODED VIEW DC PUMP All installations must comply with all applicable electrical and plumbing codes including but not limited to National Electrical Code local regional and or state plumbing codes etc Not intended for use in hazardous locations SK3185 FIGURE 3 Copyright 2019 Zoeller Co All rights reserved OPERAT...

Page 8: ...eset will clear flashing light on unit Test Will run the pump to determine if amp draw of pump is in range Controller is factory programmed to self test the pump for several seconds every 24 hours Pressing the test button will start the 24 hour timer for self testing Note Holding both the silence reset and test button at the same time for 5 seconds will cause a factory reset on the controller AQUA...

Page 9: ...ud com Locate the Fit s Device ID on the top sticker Connection Steps 1 Apply AC power to the Fit The Z Control LED will blink and then turn off indicating the Fit is in AP Mode and is transmitting an SSID see Figure B If the LED is blinking and not in AP mode press the Z Control button for 12 seconds and let go See figure A A pen or toothpick or similar is required to press the Z Control Button T...

Page 10: ...s capable of OTA or over the air firmware updates It s possible that the Fit could perform an update immediately if one is available at the Z Control Cloud If an update is taking place the Z Control LED will flicker for up to 1 minute while the update is downloaded The Z Control LED will be solid and all other LEDs will turn off while the update is being installed After up to 1 minute the Fit will...

Page 11: ...etting up WiFi creating an account or adding devices These steps should be done through the web interface using a mobile device to access the web interface is fine 4 Once the Fit s Z Control LED is solid log in to your account or create one at zcontrolcloud com see Figure D Click the Edit button next to a location and choose Add New Device Follow the directions to add your Fit by either auto detec...

Page 12: ...thatnoCOisbeingproduced achargingbatterymaybeproducinggaseousby productswhicharecausingtheCOdetector to activate Contact the manufacturer and ask for recommendations to prevent the alarm activation There are millions of batteries manufactured each year so it is impossible to guarantee consistent quality A defective battery will never become fully charged and may damage the charging circuits of the...

Reviews: