background image

7

MODEL

ProPak

508-D

ITEM

DESCRIPTION

QTY

12/18

thru

Current

Pump, 12 V DC with connector

1

155652

Battery box asm ( box and cover)

1

10-0764

Aquanot Fit controller

1

155368

operational float switch

1

155654

High water reed sensor

1

155653

Clamp, #28 worm-SS

2

004287

Inline check valve

1

153772

 

Pump, M53/115V

1

53-0001

Pump, M63/115V

1

63-0001

Pump, M98/115V

1

98-0001

Pipe, Pvc 1.5" X 10"/ Sch 40

1

019509

10

Fuse,30A/ Automotive Startard

1

016918

CHECKLIST

EXPLODED VIEW - DC PUMP

All installations must comply with all applicable electrical and plumbing codes, including, but not limited to, National Electrical Code, 

local, regional, and/or state plumbing codes, etc.  Not intended for use in hazardous locations.

SK3185

FIGURE 3

© Copyright 2019 Zoeller

®

 Co. All rights reserved.

OPERATIONAL FLOAT SWITCH

30 AMP FUSE

HIGH WATER

REED SENSOR

BATTERY BOX

DC PUMP

12 VOLT BATTERY 

SUPPLIED BY USER

WHITE LEAD TO POSITIVE

BLACK LEAD TO NEGATIVE

CLAMP

AQUANOT FIT CONTROLLER

Summary of Contents for ProPak AQUANOT FIT 508/53

Page 1: ...servicing of electrical circuits and hardware should be performed by a qualified licensed electrician 9 Pump installation and servicing should be performed by a qualified person 10 Risk of electrical shock These pumps have not been investigated for use in swimming pools and marine areas 11 Prop65 Warning for California residents Cancer and Reproductive Harm www P65Warnings ca gov 12 It is the owne...

Page 2: ...s which vary from state to state 1 DC Pump won t run a Check for proper connections b Check all wire terminal points Clean if required c Check for low battery Service battery if required d Check 30 amp fuse on controller see fig 5 If fuse is blown replace with 30 amp automotive blade fuse 2 Pump runs but pumps very little or no water without AC power a Check for low battery Battery will recharge i...

Page 3: ...stallation conforms to each of them 11 DO consult manufacturer for clarifications or questions 12 DO inspectandtestsystemforproperoperationsatleasteverythree months Copyright 2019 Zoeller Co All rights reserved ELECTRICAL PRECAUTIONS Before servicing a pump always shut off the main power breaker and then unplug the pump making sure you are wearing insulated protective sole shoes and not standing i...

Page 4: ...ed Timeforrechargedependsupontheamountofpowerconsumed bythepumpingcycleduringtheACpowerinterruption Thepumpmaygo backtothereadyrunpositioninaveryshortperiodoftime Acompletely drained battery may require up to 24 hours for full recharge If battery does not charge properly the LED battery will flash red PERFORMANCE The DC pump performance at 12 7 Vdc BATTERY SELECTION Discharge Feet of Head 5 1 5 m ...

Page 5: ...al operating level and shut off b The yellow charging light should be on The charger is replacing the energy consumed during the test The green light will come on after the charger has replaced the energy consumed during the test 3 Add distilled water to battery when necessary per battery manufacturer s instructions CAUTION Battery acid is dangerous Take proper safety precautions Do not splash the...

Page 6: ... WATER REED SENSOR 1 1 2 SCH 40 PVC PIPE X 10 254 mm LG 1 1 2 SCH 40 PVC TEE NOTE CHECK VALVE SCREWS INTO PRIMARY PUMP DISCHARGE HAND TIGHTEN ONLY WEEP HOLE MUST BE VISIBLE OPERATIONAL FLOAT SWITCH DC PUMP CLAMP HIGH WATER REED SENSOR CHECK VALVE O RING PRIMARY PUMP CLAMP DC PUMP O RING TYPICAL INSTALLATION EXPLODED VIEW OF PUMP SYSTEM SK3182 SK3223 FIGURE 2 FIGURE 1 Copyright 2019 Zoeller Co All ...

Page 7: ...Pipe Pvc 1 5 X 10 Sch 40 1 019509 10 Fuse 30A Automotive Startard 1 016918 CHECKLIST EXPLODED VIEW DC PUMP All installations must comply with all applicable electrical and plumbing codes including but not limited to National Electrical Code local regional and or state plumbing codes etc Not intended for use in hazardous locations SK3185 FIGURE 3 Copyright 2019 Zoeller Co All rights reserved OPERAT...

Page 8: ...eset will clear flashing light on unit Test Will run the pump to determine if amp draw of pump is in range Controller is factory programmed to self test the pump for several seconds every 24 hours Pressing the test button will start the 24 hour timer for self testing Note Holding both the silence reset and test button at the same time for 5 seconds will cause a factory reset on the controller AQUA...

Page 9: ...ud com Locate the Fit s Device ID on the top sticker Connection Steps 1 Apply AC power to the Fit The Z Control LED will blink and then turn off indicating the Fit is in AP Mode and is transmitting an SSID see Figure B If the LED is blinking and not in AP mode press the Z Control button for 12 seconds and let go See figure A A pen or toothpick or similar is required to press the Z Control Button T...

Page 10: ...s capable of OTA or over the air firmware updates It s possible that the Fit could perform an update immediately if one is available at the Z Control Cloud If an update is taking place the Z Control LED will flicker for up to 1 minute while the update is downloaded The Z Control LED will be solid and all other LEDs will turn off while the update is being installed After up to 1 minute the Fit will...

Page 11: ...etting up WiFi creating an account or adding devices These steps should be done through the web interface using a mobile device to access the web interface is fine 4 Once the Fit s Z Control LED is solid log in to your account or create one at zcontrolcloud com see Figure D Click the Edit button next to a location and choose Add New Device Follow the directions to add your Fit by either auto detec...

Page 12: ...thatnoCOisbeingproduced achargingbatterymaybeproducinggaseousby productswhicharecausingtheCOdetector to activate Contact the manufacturer and ask for recommendations to prevent the alarm activation There are millions of batteries manufactured each year so it is impossible to guarantee consistent quality A defective battery will never become fully charged and may damage the charging circuits of the...

Reviews: