8
FLOAT SWITCH
CONTROL CHARGER
LOCKING PIN MUST BE
INSTALLED UNDER FLOAT
ROD IN THIS LOCATION.
MOLEX 4-PIN CONNECTOR
MOLEX 2-PIN CONNECTOR
FLOAT STATUS LED
DC PUMP LED
BATTERY LED
SYSTEM READY LED
Z CONTROL LED
GROUNDED POWER CORD
SILENCE BUTTON
TEST BUTTON
WHITE LEAD
(POSITIVE)
BLACK LEAD
(NEGATIVE)
30 AMP FUSE
DC PUMP
HIGH WATER
OPERATIONAL
FIGURE 4
SK3186
FIGURE 5
SK3187
FIT CONTROLLER FUNCTIONS
There are two buttons on the front of the controller.
Silence/Reset
• Can be pressed to silence current alarms for 24 hours.
•
Can be held for longer than 3 seconds to reset alarm. Reset will clear flashing light on unit.
Test
• Will run the pump to determine if amp draw of pump is in range.
• Controller is factory programmed to self-test the pump for several seconds every 24 hours.
• Pressing the test button will start the 24-hour timer for self-testing.
Note: Holding both the silence/reset and test button at the same time for 5 seconds will cause a factory reset on the controller.
AQUANOT FIT
Solid
Flashing
Off
System Ready
No Faults (Green)
AC off with no faults
(Green)
--
Battery
Charged (Green)
Low Battery (Red)
No AC Power
Charging (Yellow)
Bad Battery (Red)
DC pump
Pump Ran (Yel-
low)
Pump Running (Yellow)
--
Pump Fault (Red)
Float Status
High Water (Red)
Float Fault (Red)
--
Z Control
Connected
Searching
Broadcasting SSID or Dormant
© Copyright 2019 Zoeller
®
Co. All rights reserved.