2
© 2020. All rights reserved.
SAFETY INFORMATION
Please read and understand this entire manual before attempting to assemble, operate, or install the product.
NOTE
: Pumps with the “UL” Mark and pumps with the “US” mark are tested to UL Standard UL778. CSA certified pumps
are certified to CSA Standard C22.2 No. 108. (CUS.)
DANGER
• FIRE/EXPLOSION HAZARD.
Pump only clear water. Do not pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not
use in a flammable and/or explosive atmosphere. Failure to follow these warnings could result in death or serious
injury and/or property damage.
• RISK OF ELECTRIC SHOCK.
These pumps have not been investigated for use in swimming pool and marine areas.
• RISK OF ELECTRIC SHOCK.
Always disconnect power source before attempting to install, service, or maintain the pump. Never handle a pump
with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.
• RISK OF ELECTRIC SHOCK.
Keep pump out of reach of children.
PACKAGE CONTENTS
DESCRIPTION
QUANTITY
A
Pump
1
B
Controller
1
C
Dual float
1
A
B
C
E
G
SPECIFICATIONS
MODEL
HP
DISCHARGE
AMPS
PERFORMANCE IN GALLONS PER MINUTE
0 FT.
5 FT.
10 FT.
15 FT.
20 FT.
STBS700
3/4
1-1/2 in.
9.0
80
72
62
50
35