FOR
SHALLOW
WELL
APPLICA
TIONS
0
- 2
5 FT
.
11
© 2020. All rights reserved.
IL1374
Wire from
motor
4
IL1373
Wire from
motor
3
IL1372
2
3. Thread the cable from the pump motor through
the strain relief into the pressure switch cavity
and tighten both screws on the strain relief. Do
not crush wire.
4. Connect the two motor wires of the motor cable
to the two inside terminals on the pressure
switch.
2. Insert an electrical wire strain relief into the
opening in the side of the pressure switch closest
to the motor.
IL1375
Wire from
motor
Ground Screws
5
5. Connect the green ground wire from the motor
cable to one of the green ground screws at the
bottom of the pressure switch.