FOR
DEEP
WELL
APPLICA
TIONS
2
5 -
7
0 FT
.
7
© 2020. All rights reserved.
PUMP TO PRESSURE TANK CONNECTION (DISCHARGE PIPE) - DEEP WELL
1. To begin the connection to the pressure tank,
install the 1 in x 3/4 in adapter (included) to pump
discharge. Install flow control body to adapter.
Using Teflon tape, position the discharge outlet of
the control body facing right as you look directly
into the face of the pump
IL2206
Control
Body
Flow Control
Screw
1 in. x 3/4 in. adapter
1
2. Assemble the pressure switch in the 1/4” tapping
adjacent and to the right of the discharge outlet
of the control valve. Refer to Pump Electrical
Connection section for pressure switch wiring.
IL1389
2
3. Tighten flow control body.
IL1390
3
IL1391
4
4. Install optional pressure gauge in 1/4” tapping
on side of pump body. Face of gauge should be
positioned so that dial can be read easily.