CARE AND MAINTENANCE
Winterizing
CAUTION:
Drain the entire system if there is
danger of freezing. A drain plug is provided at the
bottom of the pump for this purpose.
1
PREVENT
PUMP
DAMAGE!
Remove plug in
freezing weather
20
20
20
20
Breaker Box
6
IL2145
5
5. Thread in priming plug and then open optional ball
valve if installed by turning handle to line up with
the pipe.
6. Turn on breaker to start pump.
7.
IMPORTANT:
If the pump fails to prime within
five minutes:
Turn power off at the breaker box and check all pipe
connections for leaks. All connections must be water
and air tight in order for pump to operate.
All piping from the well to the pump should slope
slightly upward with no sagging. Support suction
pipe between water source and pump. Unions in
the suction line near the pump and well will aid in
servicing. Be sure to leave enough room so that
wrenches can be used easily.
NOTE
: Look for leaks or a milky color in the
discharged water, which indicates an air leak.
Re-prime if necessary, following steps 1 through
6 above. Reset breaker at the breaker box. All
connections must be water and air tight in order for
pump to operate.
IL2125
Water level
Slope pipe
upward
Pipe
support
Unions
Foot valve
7