FOR
SHALLOW
WELL
APPLICA
TIONS
0
- 2
5
FT
.
6
© 2020. All rights reserved.
1
Venturi
Tube
Ejector
1. Attach ejector to face of pump with two (2) bolts
and gasket provided. Venturi tube on the ejector
inserts into the top tapping of the face of the pump
WELL TO PUMP CONNECTION (SUCTION PIPE) - SHALLOW WELL
Glue
2
2. Make the connection to your well. Wrap all
threaded fittings with pipe tape 5 times or apply
a pipe paste (pipe dope) to ensure an air tight
connection.
The use of a union (optional) will assist with easy
connection and disconnect.
3a. NOTE: For drilled (cased) wells, a foot valve
is required in the well at the end of the pipe to
maintain prime.
IL2125
Water level
Slope pipe
upward
Pipe
support
Unions
Foot valve
3a
3b. For driven wells, a check valve is required at the
top of the well to maintain prime. Flow arrow must
point toward pump.
Pump
Flow Arrow
3b