Zodiac PI20 Series Instructions For Installation And Use Manual Download Page 4

2

in the vicinity of the moving parts during operation of the appliance. Moving parts 

can cause serious injury or even death.

WARNINGS ASSOCIATED WITH ELECTRICAL APPLIANCES

• 

The electrical supply to the appliance must be protected by a 30 mA differential 

Residual  Current  protection  Device  (RCD),  complying  with  the  standards  and 

regulations in force in the country in which it is installed.

• 

Do  not  use  any  extension  lead  when  connecting  the  appliance;  connect  the 

appliance directly to a suitable power supply circuit.

• 

If a stationary appliance is not fitted with a supply cord and a plug, or with other 

means for disconnection from the supply mains having a contact separation in all 

poles that provide full disconnection under overvoltage category III conditions, the 

instructions shall state that means for disconnection must be incorporated in the 

fixed wiring in accordance with the wiring rules.

• 

A  Suitable  disconnecting  means,  which  complies  with  all  local  and  national 

requirements for over-voltage category III, and which disconnects all poles of 

the supply circuit, must be installed in the supply circuit to the appliance. Such 

disconnecting means is not provided with the appliance and must be provided by 

the installation professional.

• 

Before carrying out any operations, check that:

 -

The  voltage  indicated  on  the  appliance  information  plate  corresponds  to  the 

mains voltage.

 -The power grid is adapted to the power requirements of the appliance, and is 

grounded. 

 -

The plug (where applicable) is suitable for the socket.

• 

In  the  event  of  anormal  operation  or  the  release  of  unusual  odours  from  the 

appliance, turn it off immediately, unplug it from its power supply and contact a 

professional.

• Before any access to the appliance for service or maintenance, ensure that it is 

switched off and completely disconnected from the power supply. Furthermore, in 

addition to confirming that the heating priority (where applicable) is deactivated, 

ensure that any other equipment or accessories connected to the appliance are 

also disconnected from the power supply circuit.

• Do not disconnect and reconnect the appliance to the power supply when in 

operation.

• Do not pull on the power cord to disconnect it from the power supply.

• If the power cord is damaged, it must be replaced by the manufacturer, its technician 

or a qualified person to guarantee safety.

• 

Do not perform maintenance or servicing operations on the appliance with wet 

hands or if the appliance is wet.

• 

Before connecting the appliance to the source of supply, ensure that the terminal 

block or supply socket to which the appliance will be connected is in good condition 

and is not damaged or corroded in any way.

• 

For  any  component  or  sub-assembly  containing  a  battery:  do  not  recharge  or 

dismantle the battery, or throw it into a fire. Do not expose it to high temperatures 

or direct sunlight.

• In stormy weather, disconnect the appliance from the power supply to prevent it 

from suffering lightning damage.

• 

Do not immerse the appliance in water (with the exception of cleaners) or mud.

WARNINGS CONCERNING APPLIANCES CONTAINING R32 REFRIGERANT

• This device contains R32 refrigerant, a class A2L refrigerant, which is considered to 

be potentially flammable.

• 

Do not discharge R32 fluid into the atmosphere. These are fluorinated greenhouse 

effect gases, covered by the Kyoto Protocol, with a Global Warming Potential (GWP) 

= 675 (EU Regulation No. 517/2014).

• 

In order to comply with relevant environmental and installations standards and 

regulations such as, but not limited to, French decree No. 2015-1790 and/or the EU 

Regulation EU 517/2014, the cooling circuit must be checked for leakage at least 

once a year. This operation must be carried out by a certified cooling appliance 

specialist.

Summary of Contents for PI20 Series

Page 1: ...H0548500_REVE 2020 02 More documents on www zodiac com Z200 PI20 Power Instructions for installation and use English Heat pump Translation of the original instructions in French EN...

Page 2: ......

Page 3: ...t they do not play with the appliance Cleaning and similar user maintenance shall not be made by children without adult supervision The appliance must be installed according to the manufacturer s inst...

Page 4: ...ensure that it is switched off and completely disconnected from the power supply Furthermore in addition to confirming that the heating priority where applicable is deactivated ensure that any other e...

Page 5: ...eratures in excess of 100 C and high pressures with the consequent risk of severe burns Area check Prior to beginning work on systems containing flammable refrigerants safety checks are necessary to e...

Page 6: ...be reported to the owner of the equipment so all parties are advised Initial safety checks shall include that capacitors are discharged this shall be done in a safe manner to avoid possibility of spa...

Page 7: ...to make repairs or for any other purpose conventional procedures shall be used However for flammable refrigerants it is important that best practice is followed since ammability Is a consideration The...

Page 8: ...ified to do so Replacement pipes must always be made of copper in compliance with standard NF EN 12735 1 Leak detection pressure test never use oxygen or dry air risk of fire or explosion use dry nitr...

Page 9: ...to prevent ignition in the event of a refrigerant release Consult manufacturer it in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and...

Page 10: ...t you read this installation and user manual as well as the Warranty booklet delivered with the device Failure to do so may result in material damage or serious or fatal injury and will invalidate the...

Page 11: ...th plug except 11M C Joint x2 D Screw in connector x2 E 40 adaptation x2 F 50 reduction x2 G Condensation evacuation kit 15 H Winterizing cap x2 I Winterizing cover Heating priority Not compatible J R...

Page 12: ...ervice pressure bar 1 5 Max Discharge Suction Pressure bar 42 1 2 Max high pressure low pressure side pressure bar 42 1 2 Head loss mCE 1 1 5 1 1 5 Minimum optimum water flow rate m h 4 Maximum water...

Page 13: ...on valve and user interface Ventilator Technical access door Pool water intake Pool water output Evaporator Grommet for heating priority cable run Location for drilling for remote control cable run de...

Page 14: ...ale is available on the back of the packaging carton front rear connectors Top view of the device with dimensions for attachment to the ground The device must not be installed In a closed and unventil...

Page 15: ...to make it easier to work on the device water entry valve by pass valve water exit valve water entry adjustment valve optional water exit adjustment valve optional water treatment minimum distance To...

Page 16: ...n plate The electricity supply cable must be insulated against any cutting or hot elements that may damage or crush it The equipment must be connected to an earth socket The electrical connection line...

Page 17: ...mp power contactor coil filtration timer power contactor tripolar or bipolar for the filtration system pump motor separate cable for the heating priority function heat pump terminal see wiring diagram...

Page 18: ...ing range sufficient to heat Cover the basin with a sheet bubble canopy canvas etc to prevent heat loss Take advantage of a period with mild outdoor temperatures on average 10 C at night your heat pum...

Page 19: ...adually so that the filter pressure is increased by 150g 0 150 bars Open valves A C and D fully then valve E by half the air which has built up in the heat pump condenser and the filtration circuit wi...

Page 20: ...the setpoint temperature is displayed fixed To read the water temperature it is imperative that the filtration is in operation and that the water flow indicator is fixed 3 4 2 Locking unlocking the k...

Page 21: ...t on a yearly basis to ensure proper operation maintain performance levels and prevent some potential failures These operations are carried out at the user s expense by a technician 4 2 1 User mainten...

Page 22: ...your heat pump cannot manage to deice its evaporator it will stop itself this means that the outdoor temperature is too low below 5 C for standard models 5 C for Defrost models The device is not worki...

Page 23: ...temperature too high 32 C maximum Wait until the temperature falls Flow controller blocked Check the flow controller Water condenser scaled up or blocked Clean the water condenser Outside temperature...

Page 24: ...p relay Earth KM4 Complementary relay C1 Compressor condenser M1 Compressor C2 Ventilator condenser M2 Ventilator CD Flow controller SD1 Water temperature sensor E1 High pressure switch SD2 Air temper...

Page 25: ...KM4 Complementary relay C1 Compressor condenser M1 Compressor C2 Ventilator condenser M2 Ventilator CD Flow controller SD1 Water temperature sensor HP High pressure switch SD2 Air temperature sensor...

Page 26: ......

Page 27: ......

Page 28: ...23 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Pour plus d...

Reviews: