❸ Use
3.1 I Operating principle
Your heat pump uses the calories (heat) in the air to heat up your pool's water. The process to heat your pool's water to
the temperature you want may take a few days as it depends on the weather conditions, your heat pump's power and
the difference between the water temperature and the temperature you want.
The heat pump is ideal for maintaining temperature.
The warmer and damper the air, the better your heat pump will perform. The outdoor parameters for optimum operation
are an air temperature of 27°C, a water temperature of 27°C and 80% hygrometry.
Tips: improve your pool's temperature rise and maintenance
•
Anticipate the commissioning of your pool far enough in advance before you use it.
•
For the temperature rise, set the filtration pump to continuous operation (24/24).
• To maintain the temperature throughout the season, switch to
“automatic” circulation equal to at least
the water temperature divided by two (the longer this time will be, the more the heat pump will have an
operating range sufficient to heat).
•
Cover the basin with a sheet (bubble canopy, canvas, etc.) to prevent heat loss.
•
Take advantage of a period with mild outdoor temperatures (on average > 10°C at night); your heat pump
will be even more effective if it runs during the warmest hours of the day.
•
Keep the evaporator clean (see § “4.2 I Maintenance”).
•
Set the temperature you want and let the heat pump run (adjusting the setpoint to maximum will not
heat the water more quickly).
•
Connect the “Heating priority”; the filtration pump and heat pump operating time will be set according
to requirements.
3.2 User interface presentation
Display screen (default: setpoint temperature)
"On/off" button
Pool water temperature reading or parameter setting button
Value setting buttons
Symbol
Designation
Fixed
Flashing
Off
Water flow
Water flow ok
Water flow too low or missing
/
Heating
Active
starting
Inactive
Ambient air
temperature
Sufficient
Insufficient
/
Priority heating
connected
Priority heating connected and
heating request
Priority heating connected but no
heating request
Priority heating
not connected
Fault
Fault in progress, see § “5.2 I
Error code display”
Heating priority connected,
heating requested but water flow
too low or missing
No fault