H03620
‐
00.D2.EN
–
2013/03
8
3.1.2
Locking
and
releasing
the
key
pad
Press
and
for
3
seconds:
or
3.2
Starting
the
device
check
that
no
tools
or
other
objects
have
been
left
inside
the
device,
the
access
door
for
technical
components
must
be
fitted,
set
the
by
‐
pass
and
setting
valves
(see
§
2.4)
as
follows:
-
valve
1
completely
open,
-
valves
2
‐
3
‐
4
&
5
closed.
An
incorrect
setting
of
the
by
‐
pass
valve
may
lead
to
device
malfunction
switch
on
the
filter
system,
progressively
close
valve
1
in
order
to
increase
the
filter
pressure
to
150
g
(0.150
bar)
,
open
valves
2,
3
and
4
completely,
then
half
open
valve
5
(see
§2.4)
(the
air
accumulated
in
the
heat
pump
condenser
and
in
the
filter
circuit
is
then
bled),
If
valves
4
and
5
are
not
fitted,
open
valve
1
completely,
and
half
close
valve
3.
power
‐
up
the
heat
pump,
if
the
heat
pump
is
on
stand
‐
by:
,
press
on
for
3
seconds,
will
appear
for
2
seconds,
and
for
3
seconds,
and
the
water
and
set
‐
point
temperatures
will
be
displayed:
,
a
2
‐
minute
delay
will
start,
set
the
required
water
temperature:
-
press
to
increase
temperature,
-
press
to
decrease
temperature,
When
the
pool
reaches
the
required
temperature,
the
heat
pump
will
automatically
stop.
set
the
water
flow
‐
rate
using
the
menu
,
when
the
indicator
is
steady:
press
to
display
the
water
flow
‐
rate
status:
Status
water
flow
‐
rate
ok
no
water
flow
water
flow
‐
rate
too
weak
water
flow
‐
rate
too
strong
Display
set
the
flow
‐
rate
using
valve
5
(or
3
if
no
valve
5
is
fitted),
and,
to
quit
the
menu,
press
.
During
this
adjustment
phase,
wait
for
a
few
minutes
after
each
change
in
valve
position
to
allow
the
device
to
balance.
3.3
Checks
to
perform
after
start
‐
up
The
heat
pump
must
stop
when:
the
set
‐
point
temperature
is
lowered
using
the
digital
control
panel,
filtering
is
stopped
or
valve
2
or
3
is
closed
3,
the
digital
control
panel
is
turned
off
by
pressing
,