H03620
‐
00.D2.EN
–
2013/03
3
1.3
Operating
conditions
Operating
range:
air
temperature
of
between
5
°C
and
38
°C
for
standard
models,
air
temperature
of
between
‐
8
°C
and
38
°C
for
TSR
models,
water
temperature
of
between
10
°C
and
32
°C,
Maximum
temperature
of
32°C
to
protect
the
pool
liner.
The
TSR
version
also
features
a
de
‐
icing
function
by
using
forced
ventilation
or
reversed
cycle.
1.4
Technical
specifications
PFP
Voltage
Power
input*
Power
output*
Nominal
current
input*
COP*
kW
kW
A
6M
230V
‐
50Hz
1.4
6.8
6.7
4.7
8M
230V
‐
50Hz
1.7
7.6
7.9
4.5
11M
230V
‐
50Hz
2.2
10.4
10.3
4.7
11T
400V
‐
50Hz
2.2
10.5
4.25
4.8
13M
230V
‐
50Hz
2.88
13.9
13
4.8
11M
TSR
230V
‐
50Hz
2.2
10.7
10
4.9
11T
TSR
400V
‐
50Hz
2.2
10.5
4.4
4.8
15M
TSR
230V
‐
50Hz
3.6
15.7
16
4.5
15T
TSR
400V
‐
50Hz
3.6
15.7
7.4
4.5
*
with
ambient
air
at
+15
°C,
pool
water
at
26
°C,
and
relative
humidity
of
70%
(according
to
French
standard
NF
‐
414)
protection
class:
IP
24
refrigerant
gas:
R410A
refrigerant
charge:
see
product
information
plate
class:
I,
degree
of
pollution:
2,
overvoltage
category:
II
2.
Installation
Do
not
take
grip
on
the
outer
casing
to
pick
up
the
device,
hold
the
base.
2.1
Access
to
the
technical
compartment
2.2
Selecting
an
installation
site
The
device
must
be
installed
outdoors
and
there
must
be
adequate
open
space
surrounding
it
(see
§2.4).
the
heat
pump
must
be
installed
at
a
certain
distance
from
the
pool
so
as
to
avoid
exposure
to
water
splashes.
The
appropriate
distance
should
be
defined
according
to
the
national
electrical
standards
that
apply
in
the
country
of
installation
(for
France:
3.5
meters).
the
heat
pump
must
not
be
installed:
-
near
a
source
of
heat
or
inflammable
gas,
-
near
a
road/passage
where
there
is
a
risk
of
water
and
mud
splashes,
-
facing
a
strong
wind,
-
with
the
vent
facing
toward
a
permanent
or
temporary
obstacle
(window,
wall,
hedge,
etc…),
it
must
be
at
least
4
meters
from
any
potential
obstacle.