H03620
‐
00.D2.EN
–
2013/03
5
Disposing
of
condensation:
Warning:
your
device
can
produce
several
litres
of
water
per
day.
It
is
strongly
recommended
to
guide
the
flow
to
drains.
connect
a
Ø18
interior
pipe
(not
supplied),
to
the
grooved
end
‐
piece
mounted
on
the
base
of
the
appliance,
outlet:
to
the
back
or
on
the
side:
2.5
Electrical
connections
2.5.1
Voltage
and
protection
the
electrical
supply
to
the
heat
pump
must
include
a
protection
and
circuit
‐
breaker
device
(not
supplied)
complying
with
the
standards
and
regulations
in
force
in
the
country,
additional
protection
may
be
required
during
installation
to
protect
against
overvoltage
category
II,
the
device
is
designed
for
connection
to
a
general
power
grid
with
TT
and
TN.S
grounding
systems,
electrical
protection:
circuit
‐
breaker
(curve
D)
or
fuse
(Am)
(see
§
2.5.3
for
ratings),
and
with
a
30
mA
dedicated
differential
trip
switch
(circuit
‐
breaker
or
switch).
electrical
conduits
must
be
secured,
tolerance
for
voltage
variation:
±
6%
(during
operation),
use
cable
suitable
for
outdoor
use,
type
RO2V
or
equivalent
in
countries
outside
of
the
European
community,
with
an
outer
diameter
between
9
and
18
mm,
use
the
cable
gland
to
run
the
supply
cable
into
the
device.
2.5.2
Connections
the
electrical
supply
cable
must
not
be
exposed
to
elements
that
are
sharp,
hot
or
at
risk
of
being
crushed,
check
that
all
cables
are
secure
and
all
terminal
connections
are
correct.
Loose
terminals
may
cause
the
supply
terminal
board
to
overheat
and
will
void
the
warranty.
The
device
must
be
connected
to
the
earth
(grounded)
Risk
of
electric
shock
inside
the
device
The
device
must
only
be
commissioned
by
a
qualified
and
experienced
technician
If
the
power
cable
is
damaged,
it
must
be
replaced
by
a
qualified
technician
Single
‐
phase
Three
‐
phase
2.5.3
Cable
cross
‐
sections
•supply
cable
cross
‐
section:
cables
with
a
maximum
length
of
20
metres
(calculation
base:
5A/mm²),
must
be
checked
and
adapted
depending
on
installation
conditions.
PFP
Voltage
Maximum
I
input
Cable
cross
‐
section
Electrical
protection
A
mm²
A
6M
230V
‐
50Hz
9
3
x
2.5
3G2.5
16
8M
230V
‐
50Hz
10
3
x
2.5
3G2.5
16
11M
230V
‐
50Hz
14.5
3
x
2.5
3G2.5
16
11T
400V
‐
50Hz
5
5
x
2.5
5G2.5
10
13M
230V
‐
50Hz
16.1
3
x
4
3G4
20
15M
230V
‐
50Hz
22
3
x
6
3G6
25
15T
400V
‐
50Hz
9.4
5
x
2.5
5G2.5
10
phase
(L)
+
neutral
(N)
+
Earth
(PE)
phases
(L1
+
L2
+
L3)
+
neutral
(N)
+
Earth
(PE)