background image

 1 

Product Specifications 

2

 2 

Dimensions 

3

 3 

Wiring Diagram 

4

 4 

Refrigeration Cycle Diagram 

6

 5 

Air Conditioner Performance Evaluation 

7

 6 

Troubleshooting Guide 

7

 7 

Operating Instructions 

9

© 2000 Matsushita Industrial Corp. Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.

CW-C180ES
CW-C240ES
CW-A180ES
CW-A240ES
CW-SC180ES

 8 

How to Install 

13

 9 

Technical Data 

17

 10 Care and Maintenance 

19

 11 Service Information 

20

 12 Exploded View 

21

 13 Replacement Part List 

22

Room Air Conditioner

CONTENTS

 Page 

Page

Order No. MAC0011061C3

Summary of Contents for CW-C180ES

Page 1: ...s 9 2000 Matsushita Industrial Corp Sdn Bhd 11969 T All rights reserved Unauthorized copying and distribution is a violation of law CW C180ES CW C240ES CW A180ES CW A240ES CW SC180ES 8 How to Install...

Page 2: ...odel CW A180ES CW A240ES Cooling Heating Cooling Heating Phase Single Single Voltage 220 V 220 V Frequency 60 Hz 60 Hz Capacity 5 13 kW 17 500 Btu h 4 60 kW 15 700 Btu h 6 45 kW 22 000 Btu h 5 60 kW 1...

Page 3: ...32 220 F 12 19 32 320 10 1 4 260 G 4 11 32 110 9 7 16 240 H 13 5 32 334 12 3 4 324 I 5 3 16 132 7 9 16 192 J 9 7 32 234 10 254 K 3 5 32 80 L 12 17 32 318 M 10 5 16 262 N 1 21 32 42 O 12 17 32 318 P 2...

Page 4: ...ow 41 1 27 13 Capacitor CWA312048 5 F 440VAC CWA312052 8 F 440VAC 3 1 2 Resistance of Compressor windings and the rated Capacitor CW C180ES CW SC180ES CW C240ES Connection 2KS282H6CA02 2JS350H4CA02 C...

Page 5: ...Capacitor CWA312048 5 F 440VAC CWA312052 8 F 440VAC 3 2 2 Resistance of Compressor windings and the rated Capacitor CW A180ES CW A240ES Connection 2KS282H6CA02 2JS350H4CA02 C R 1 239 0 934 C S 1 721...

Page 6: ...78 88 B 2 55 2 75 54 64 2 67 2 87 53 63 C 0 63 0 69 10 15 0 57 0 62 9 14 D 0 58 0 64 9 14 0 55 0 60 8 13 Note Indoor temperature at 29 C DB 19 C WB and Outdoor at 46 C DB 24 C WB for Cooling 4 2 2 He...

Page 7: ...at exchanger Leakage of refrigerant Refrigerant system is blocked None Improve heat radiation at outdoor heat exchanger Locate and repair leak Flush refrigeration cycle Under 14 C 25 2 F Higher than s...

Page 8: ...ion Leakage of refrigerant or refrigeration system is blocked Set it lower or higher Close Vent door Clean or replace Air Filter Consider building an AWNING Remove obstacles or reinstall unit Clean th...

Page 9: ...tilation door is closed and the air will be circulated inside the room and conditioned 7 1 1 3 Neon Lamp Indicator Neon Lamp Indicator The green neon light mounted above the control panel indicates co...

Page 10: ...rmostat Control Knob as shown in Fig 4 Usually 6 7 is the recommended setting position Note When the Thermostat Control Knob is set to 10 moisture may freeze onto the evaporator fins and prevent effec...

Page 11: ...he ventilation door is closed and the air will be circulated inside the room and conditioned 7 2 1 3 Neon Lamp Indicator Neon Lamp Indicator The green neon light mounted above the control panel indica...

Page 12: ...the Thermostat Control Knob as shown in Fig 4 Usually 6 7 is the recommended setting position for cooling and 4 5 for heating Note When the Thermostat Control Knob is set to 10 moisture may freeze ont...

Page 13: ...p in the fixed installation circuit Applicable for models without power supply plug only 8 1 2 Select the Best Location Install the unit at the nearest power outlet The air conditioner should be insta...

Page 14: ...then secure it with wood screws or nails Note Tilt down for better drainage max 10 mm 8 3 4 Slide the Chassis back into the Cabinet 8 3 5 Lock the Chassis to the Cabinet reusing the Chassis Locking B...

Page 15: ...r When performing the following steps do not pull the bottom edge of the Front Grille towards you more than 3 inches or you may damage the top tabs 2 Press inward on the Cabinet near the bottom right...

Page 16: ...ndenser being corroded easily 1 Slide the Chassis out from the Cabinet 2 Remove the rubber plug from the Base Pan If any 3 Install the Drain Pan at the right corner of the Cabinet with 2 screws 4 Conn...

Page 17: ...1 1 2 Mechanical Thermostat Heating 9 Technical Data 9 1 Thermostat Characteristics 9 1 1 CW A180ES CW A240ES 9 1 2 CW C180ES CW C240ES CW SC180ES 9 1 2 1 Mechanical Thermostat Cooling 17 CW C180ES C...

Page 18: ...ng Characteristics Vs Outdoor Temperature 9 2 1 2 Heating Characteristics Vs Outdoor Temperature 9 2 2 2 Heating Characteristics Vs Outdoor Temperature 9 2 Operation Characteristics 9 2 1 CW A180ES 9...

Page 19: ...ove the Front Intake Grille 2 Tilt up and pull out the Air Filter by the holder 3 Vacuum the front of the filter and then wash the back of it with water If it is badly soiled wash with a mild househol...

Page 20: ...4 Remove the 2 knobs 5 Take off the Control Panel 6 Release the thermostat sensor from the sensor holder 7 Loosen the 3 screws of the Control Board 8 Slide the Control Board out from the chassis Contr...

Page 21: ...ed View Note The above exploded view is for the purpose of parts disassembly and replacement The non numbered parts are not kept as standard service parts 21 CW C180ES CW C240ES CW A180ES CW A240ES CW...

Page 22: ...lve 1 CWB00003 CWB00003 220 Evaporator 1 CWB30C1064 CWB30C1063 CWB30C1076 300 Fan Motor 1 CWA951053 CWA951059 CWA951069 CWA951073 302 Capacitor Fan Motor 1 CWA312048 5 F 440VAC CWA312052 8 F 440VAC 30...

Page 23: ...ied from MAICO Malaysia Vendor Code 061 E Filter Frame 716 and E Filter 717 is an optional part Supplied through sales route 23 CW C180ES CW C240ES CW A180ES CW A240ES CW SC180ES MAICO Printed in Mala...